Gas fire with open combustion system
Table of Contents

Advertisement

Bellfi res
4
Dismantle the fl ue gas outlet connection: (see pictures 2.1.2)
In order to connect the (insulated) aluminium or (fl exible) stainless steel fl ue
(Ø100 mm) onto the appliance, the fl ue gas outlet connection must fi rst be
dismantled from inside the appliance.
a.
Disassemble fi rst the baffl e plate at the top of the combustion chamber, by a
front screw loosening, and take the plate out.
b.
Disassemble after this the draft diverter from the top of the combustion
chamber, by loosening the screws around and take it out.
c.
Disassemble the plate with fl ue outlet connection piece, by loosening the
bolts on the outer edge. Do not fully unscrew the bolts around the fl ue outlet
connection piece! The plate with the fl ue outlet can now be removed.
5
Assembling the fl ue:
Carefully pull the fl ue downwards through the appliance and secure to the fl ue gas
outlet connection. If necessary secure the connection with a few stainless steel
parker screws and/or a hose clip.
Ø4" Flue: