Toro 34225 Operator's Manual page 25

Stand-on spreader/sprayer
Table of Contents

Advertisement

Figure 24
Pan spacing for small granule materials
1. Spreader moving toward
pans
2. Center collection pan
3. Lest collection pans (no
gap between each)
3.
Move the machine far enough away from the
test area (where the collection pans are located)
to ensure that the machine travels at the desired
spreading speed before reaching the site.
4.
Determine the application rate and the related
drop-rate cam setting; refer to
(page
30).
5.
Rotate the drop rate cam
setting you determined in step 4.
Figure 25
1. Drop rate cam
6.
Fill the hopper approximately half-full with the
desired material; refer to
Hopper (page
27).
g027327
4. Right collection pans (no
gap between each)
5. L1 and R1 collection pan
gap (spread apart to allow
machine to pass through)
6. Graduated measuring
cylinder
Spreading Charts
(Figure
25) to the cam
g259776
Filling the Spreader
Determining the Distribution Pattern
1.
Set the spreader pattern control to the middle of
its travel; refer to .
2.
Set the impeller speed to the appropriate
broadcasting rate.
3.
Drive the machine toward the test site at the
appropriate speed.
4.
As you approach the center pan, pull the wide
distribution granular gate control to the open
position, and drive over the center pan.
5.
Close the gate control, move motion-control
lever to the N
engine, wait for all moving parts to stop, remove
key, and engage parking brake.
6.
Label each graduated measuring cylinder to
correspond with the distribution pans (such as
L2, L1, Center, R1, R2); refer to
Figure
24.
7.
One at a time, take a collection pan and dump
the contents into the corresponding graduated
cylinder. Record the amount of material
collected and return the pan to its location.
Repeat this until all pan contents have been
emptied.
Note:
Repeat broadcasting over the test site
several times, moving in the same direction
each time, until enough material is dispensed to
the collection pan to half fill a graduated cylinder.
8.
With the graduated measuring cylinder in the
same straight line as the pans, evaluate the
volume of material in each cylinder to determine
the quality of the distribution from the spreader.
9.
To adjust the spreader pattern, refer to the
Adjusting the Spreader Pattern (page
10.
Fill the hopper half-full of the desired material
and repeat steps
a uniform pattern.
Determining the Effective Spreading Width
Use the effective width to determine the uniform
distribution of the material.
Note:
The spreading width range is 6 to 8 m (20 to
25 ft).
1.
After the spreader pattern is correctly adjusted,
evaluate the amount of material in the center
graduated measuring cylinder.
2.
Locate the 2 graduated cylinder, one each side
of center, that contain 1/2 the measured amount
of the material that you observed in the center
graduated cylinder.
3.
Go to the two corresponding pans. Starting from
the outer edge, measure the distance between
25
position, shut off the
EUTRAL
Figure 23
1
through
9
until you achieve
and
31).

Advertisement