Modes; Pellet Operation Heat/Easy/Automatic/Room; Pellet Container Refilling During Operation; Emergency Operation - Heating Up Without Electrical Ignition - RIKA PICO Operating Manual

Hide thumbs Also See for PICO:
Table of Contents

Advertisement

Available languages

Available languages

9. MODES

Note
When operated correctly, your stove can not overheat. Improper operation
may shorten the life expectancy of electrical components (blowers, motors
and electric control) and is not allowed!

Pellet operation Heat/Easy/Automatic/Room

HEAT/EASY
The pellet burner start and stop as well as the setting of the required heat
output are executed directly in the HOME – main menu.
AUTOMATIC MODE
The change between standby operation and neutral as well as the setting of the
required heat output are executed via the display in the HOME – main menu.
The pellet burner starts in standby mode within the heating times when the
actual room temperature is below the set room temperature (ON-T), or outside
of the heating times when the actual room temperature is below the setback
temperature (OFF-T).
When achieving the set room temperature, the pellet burner stops.
Stove start is not possible in neutral status (OFF), the system is switched off.
ROOM MODE
The change between standby operation and neutral as well as the setting of the
required heat output are executed via the display in the HOME – main menu.
The pellet burner starts in standby mode if the actual room temperature is
below the set room temperature.
When achieving the set room temperature, the pellet burner stops.
Stove start is not possible in neutral status (OFF), the system is switched off.
Pellet container ref illing during operation
Note
CAUTION when filling! Avoid direct contact between the plastic bag and the
hot stove. Immediately remove all pellets that have fallen on the hot stove or
next to the container!
We recommend always having a suitable amount of pellets in the container
to prevent the fire from extinguishing due to a lack of fuel. Check the level
frequently. However the container lid should be kept closed, except during
filling.
If you refill the container during operation (open the container lid), the fan will
speed up and the pellet auger will stop; operation will only be continued once
the container lid is closed again (see WARNING AND ERROR MESSAGES)
Pellet container capacity (see Technical Data).
Emergency operation ‑ heating up without
electrical Ignition
If the ignition cartridge fail, firelighters can be used for an emergency operation.
First, start the stove as usual. Wait for the turning of the grid (only for units with
turning grids). Then open the combustion chamber door and give a handful
of pellets with the firelighter into the clean burn pot, light it up and close the
combustion chamber door.
Note
Do not use flammable liquids to light up the fire!
|25
24

Advertisement

Chapters

Table of Contents
loading