  • Page 1 REVO II RAO REVO II PGI* Operating manual *PGI only for France, Belgium & Switzerland...
  • Page 2: Table Of Contents

    Spare part overview exploded diagram RAO/PGI ������������������������������������������������������������������������������������������������������������������������������������ 6 Spare part overview article numbers ��������������������������������������������������������������������������������������������������������������������������������������������������������������������7 Dimensions of REVO II RAO/PGI ��������������������������������������������������������������������������������������������������������������������������������������������������������������������������������� 8 Amount of Fuel �������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������� 8 Technical data for REVO II RAO/PGI ���������������������������������������������������������������������������������������������������������������������������������������������������������������������� 8 Packaging �������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������� 8 Electrical connection ����������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������� 8 2. INSTALLING THE STOVE General information �������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������...
  • Page 3: Preface

    7. COMFORT OPTIONS Room sensor, Radio room sensor ��������������������������������������������������������������������������������������������������������������������������������������������������������������������������� 16 GSM Control ������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������ 16 Interface for various options �������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������� 16 External room thermostat �������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������� 16 External connection cable bridge ������������������������������������������������������������������������������������������������������������������������������������������������������������������������� 16 Option firenet ��������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������� 16 8. MAINTENANCE Open the combustion chamber door �����������������������������������������������������������������������������������������������������������������������������������������������������������������17 Empty the ash drawer �������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������17 Cleaning the flame temperature sensor ����������������������������������������������������������������������������������������������������������������������������������������������������������17 Cleaning of the burn pot - daily �������������������������������������������������������������������������������������������������������������������������������������������������������������������������������17...
  • Page 4: Spare Part Overview Exploded Diagram

    Spare part overview exploded diagram...
  • Page 6: Spare Part Overview Exploded Diagram Rao/Pgi

    Spare part overview exploded diagram RAO/PGI...
  • Page 7: Spare Part Overview Article Numbers

    Spare part overview article numbers Art.Nr. Description Art.Nr. Description Art.Nr. Description N110032 Hexagonal screw N112297 Self-locking nut B12301 Auger L01998 Closure flap N110501 Circlips Z35182 Friction bearing Di16 Z37918 Locking bolt Z34854 Hinge shaft Z31674 Centring plate L01450 Closure plate L03691 Bottom hinge left L00797...
  • Page 8: Dimensions Of Revo Ii Rao/Pgi

    Dimensions of REVO II RAO/PGI Technical data for REVO II RAO/PGI RO-T3 RO-S Technical data 2,5 - 8 Heating power range [kW] Room heating capacity (depending 50 - 220 [m3] on house insulation) till 1,9 Fuel consumption [kg/h] Pellet container capacity*...
  • Page 9: Installing The Stove

    Ø 50 mm or Ø 60 mm for pellet stoves� Fix it with a hose clamp (not included!)� At pellet stoves with longer intake We recommend original flue pipes from RIKA for proper connection� pipes than 1 m the diameter should be increased to 100 mm� (see RIKA range)�...
  • Page 10: Important Information

    RIKA stoves should only be installed in rooms with normal humidity (dry areas according to VDE 0100 Part 200)� The furnaces are not splash water protected and may not be installed in wet areas�...
  • Page 11: Prior To Set

    Stoves type 1 (BA 1): Prior to set up Suitable for multiple occupancy� (Note the different country Floor bearing capacity regulations�) Ensure that the substructure is capable of bearing the weight of the These may only be operated with the combustion chamber door stove prior to set-up�...
  • Page 12: Brief Information On Fuel - Pellets

    4. BRIEF INFORMATION ON FUEL - PELLETS Your pellet stove is only approved for the burning of pellets of tested What are pellets? quality� Please ask your pellet stove dealer for tested fuel and a list of monitored fuel manufacturers� Wood pellets are a standardised fuel�...
  • Page 13: Technology And Safety Functions

    5. TECHNOLOGY AND SAFETY FUNCTIONS The technological advances in your new combi stove are the result of Automatic cleaning cycle years of testing and practical experience� The practical advantages of your pellet stove are convincing: The speed of the flue gas fan is increased every hour for a short period to blow ash from the burn pot, increasing the operational safety�...
  • Page 14: Assembly / Disassembly Side Panels

    6. ASSEMBLY / DISASSEMBLY SIDE PANELS Disassembly stones Note Only work on the unit when the mains plug has been disconnected Loosen the 4 screws of the convection fins� and the stove has cooled down completely� Note During assembly / dismantling do not allow objects (screws etc�) to fall into the pellet container –...
  • Page 15 Remove the bottom stone holder� Loosen the hexagonal screw only on one side� # 13 Tilt the stone carefully sidewards and lift him up� The stone tilts forwards� Lift him carefully up to remove� Pay attention to the combustion chamber door� Repeat the procedure on the second side�...
  • Page 16: Comfort Options

    7. COMFORT OPTIONS Room sensor, Radio room sensor External room thermostat This option permits control of your stove via room temperature� You Your stove has an interface on the rear wall to which you can can set both the room temperature and the heating times required� connect a customary room thermostat�...
  • Page 17: Maintenance

    The ash should be stored first and slaked with water� Note We recommend at least once a year to have all maintenance carried out by your RIKA dealer� Note Ash may contain embers – only place ash in steel sheet containers! Open the combustion chamber door To open or close the combustion chamber door use the included key�...
  • Page 18: Cleaning

    9. CLEANING Cleaning the flue gas channels and flue Your RIKA dealer will gladly advise you about their service and gas collecting duct maintenance offers� The flue gas channels are situated beneath and beside the combustion chamber� Depending on pellet consumption, a message prompting cleaning of the stove appears on the display in regular intervals�...
  • Page 19: Cleaning The Flue Pipes

    Remove the cleaning lid� Unscrew the two wing nuts and remove the outer cleaning lid� Vacuum the combustion residues off the flue gas collecting duct, especially the area to the convection fan� Vacuum the combustion residues off the flue gas collecting duct, especially the area to the convection fan�...
  • Page 20: Problems - Possible Solutions

    10. PROBLEMS - POSSIBLE SOLUTIONS Problem 1 Problem 3 Fire burns with weak, orange flame� Pellets heap up in fire trough, Flue gas discharge when wood is added and during heating phase� window soots up� Cause(s) Cause(s) Leaking cleaning openings Insufficient combustion air Chimney draught too low Poor chimney draught...
  • Page 21: Instructions For Commissioning Protocol

    Note Please return 1 completed protocol for putting into service to Warranty terms RIKA Innovative Ofentechnik GmbH, Müllerviertel 20, 4563 Difference between warranty (statutory) and guarantee (voluntary), Micheldorf, Austria� terms of guarantee, determination of wearing parts, reference to pellet quality to be used and the consequences of poor quality�...
  • Page 22 Please contact your warranty partner for any warranty questions or claims� This is your dealer or installation company� No warranty claims can be accepted without proper putting into operation, proper operation according to the operating instructions and the supplements in this information sheet� Protocol for putting into operation for RIKA pellet and combi stoves Date:____________________ Installation address...
  • Page 23: Warranty

    In case of doubt as well as missing or incorrect translations, the German version is the only valid one� For the purpose of timely damage limitation the claimant is required to file the warranty claim with the RIKA dealer in writing, submitting the invoice and stating the purchase date, model name, serial number and reason for complaint�...
  • Page 24 German version is the only 4563 Micheldorf / AUSTRIA valid one. Technical and design changes, as well Tel.: +43 (0)7582/686 - 41, Fax: -43 as typesetting and printing errors reserved. E-Mail: verkauf@rika.at www.rika.at © 2019 | RIKA Innovative Ofentechnik GmbH...