Specifications - Friedrich VPR VRP07K Installation & Operation Manual

Variable refrigerant packaged heat pump
Table of Contents

Advertisement

General Specifications
Nomenclature
V
R
P
Series
VRP Heat Pump
Nominal Capacity (Btu /Hr.)
07 = 3800 - 10000 Operating Range
Voltage
K = 230/208 V
R = 265 V
Heater Watts
25 = 2.5 kW
34 = 3.4 kW
Model
Cooling Performance Data (Cooling Standards: 95°F DB/75°F WB outdoor, 80°F DB/67°F WB indoor)
Voltage
Cooling Btu (Rated)
Cooling Btu (Min. - Max)
Outdoor Operating Range (°F )
Power (W)
EER
IEER*
Sensible Heat Ratio
Cooling Amps
Heat Pump Performance Data
Voltage
Heating Btu ( Rated @ 47° F )
Heating Btu ( @ 17° F )
Heating Btu (Min. - Max.)
Heat Pump Outdoor Operating Range (°F )
COP
Heating Power (W)
Heat Pump Amps
*Integrated Energy Efficiency Ratio (IEER) is calculated based on AHRI Standard 390 - 2021
0
7
K
2
5
S
S
D
S= Standard
R= Reheat
Outdoor Air/ Ventilation
S= Standard No FreshAire™
F= Single OA Fan 35 CFM
230/208
230/208
S
A
Marketing
Revision
S= Standard
L= Basepan Heat
Plenum and Louver Configuration
D= Standard (VRP07 Only)
VRP07K / VRP07R
265
7000
3800 - 10000
55 - 115
636
11.0
19.1
0.77
3.2
265
7000
3500
2800 - 9000
0 - 70
3.3
621
3.2
-A00
Engineering
Revision
4