General Specifications
Nomenclature
V
R
P
Series
VRP Heat Pump
Nominal Capacity (Btu /Hr.)
36 = 20,000 - 36,000
Voltage
K = 230/208 V
Heater watts
00 = 0.0 kW
10 = 10.0 kW
15 = 15.0 KW
Model
Cooling Performance Data (Cooling Standards: 95°F DB/75°F WB outdoor, 80°F DB/67°F WB indoor)
Voltage
Cooling Btu (Rated)
Cooling Btu (Min. - Max)
Outdoor Operating Range (°F )
Power (W)
SEER
EER
Sensible Heat Ratio
Cooling Amps
Heat Pump Performance Data
Voltage
Heating Btu ( Rated @ 47° F )
Heating Btu ( @ 17° F )
Heating Btu (Min. - Max.)
Heat Pump Outdoor Operating Range (°F )*
COP ( Rated @ 47° F )
HSPF
Heating Power (W)
Heating Amps
Due to continuing research in new energy-saving technology, specifications are subject to change without notice.
3
6
K
0
0
S
S
S= Standard
Outdoor Air/ Ventilation** S= Standard unit. No FreshAire™
F= Single OA Fan Powered FreshAire System 80 CFM
D= Dual OA Fans Powered FreshAire System 130 CFM
VRP36K
230/208
20,000 - 36,000
55 - 115
230/208
16,000 - 30,000
C
S
-A
Engineering code
S - Standard
L = Low Ambient Heat
Plenum and louver configuration
C= Only for 36000 Btu units
33,400
2990
15.5
11.0
0.76
14.2
28,500
18,300
0 - 70
3.25
8.6
2570
12.26
4