Electrical Data - Friedrich VPR VRP07K Installation & Operation Manual

Variable refrigerant packaged heat pump
Table of Contents

Advertisement

Electrical Data

VRP Model
Voltage
230
208
230
VRP07K
208
230
208
VRP07R
265
MCA = Minimum Circuit Ampacity
MOP / MOCP - Maximum Overcurrent Protection / Breaker Size
Minimum Circuit Amps (MCA) and MOCP values in the above table are calculated in accordance with The NEC.Article 440
Electrical Requirements
Wire Size
Use ONLY wire size recommended for
single outlet branch circuit.
Use ONLY type and size fuse or HACR cir-
Fuse/Circuit
Breaker
cuit breaker indicated on unit's rating guide.
Proper over current protection to the units is
the responsibility of the owner.
Grounding
Unit MUST be grounded from branch circuit
to unit, or through separate ground wire
provided on permanently connected units.
Ensure that branch circuit or general pur-
pose outlet is grounded.
Wire Sizing
Use recommended wire size given in tables
and install a single branch circuit. All wiring
must comply with local and national codes.
NOTE: Use copper conductors only.
NOTE: All field wiring must comply with NEC and local codes. It is the installer's responsibility to ensure that the electrical codes are
met.
Electric
Electric
Heater
Heating
ID Blower
Watts
Btu
Amps
0
0
0
0
2500
8530
2045
6980
3400
11600
2780
9490
0
0
2500
8530
3400
9490
Total
Electric
OD Blower
Heating
Amps
Amps
0.7
0.5
3.2
0.7
0.5
3.2
0.7
0.5
11.5
0.7
0.5
10.6
0.7
0.5
15.4
0.7
0.5
14.1
0.5
0.5
4.8
0.5
0.5
9.9
0.5
0.5
13.3
Electrical Rating Table
NOTE: Use copper conductors ONLY. Wire sizes are per NEC.
Recommended Branch Circuit Sizes*
Nameplate Maximum Circuit Breaker Size
15A
20A
AWG - American Wire Gauge
* Single circuit from main box.
** Based on 100' or less of copper, single insulated conductor at 60˚ C
MCA
MOP / MOCP
8.1
15
14.4
15
19.3
20
7.9
15
12.5
15
16.7
20
AWG Wiring Size**
14
12
6

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vpr vrp07r