The actual time of restart is the network reconnection period times the number of reconnections. No special requirements
suggest using the factory default parameters.

3.6.2 Timeout restart function

Support the timeout restart function (default: 300 seconds), which is mainly used to ensure the long-term stable operation
of the device. If the device does not receive data within the set timeout restart time, the device will restart operation, so as to
avoid the impact of abnormal conditions on communication.
When the timeout restart function is turned on, the timeout restart time setting parameter range is (60-65535) seconds.

3.6.3 Configuration tool software settings

Open the configuration tool software, search the device, double-click the identified device, and pop up the parameter query
configuration interface. You can customize the relevant parameters according to the requirements, and then save the
configuration, restart the device, and complete the parameter modification.
[pour]:
Do not use multiple upper computer in the same LAN environment, multi-network card industrial control machine should
be temporarily disabled without using the network card, otherwise the upper computer will be abnormal (the same equipment
displayed for many times, the equipment can not be found)
The upper computer blocks the wireless network card, so it must be connected to the network cable to use the upper
computer. The wireless network card can be configured through the web page.

3.6.4 Short connection function

In client mode, short network connection is supported (this function is turned off by default). TCP short connection is
mainly used to save server resource overhead, and is generally applied to multi-point (multi-client) point-to-point (server)
scenarios.
The TCP short connection function is applied to TCP Client mode. After the short connection function is enabled, the
server only requests the connection when the connection is sent. After the connection is successful, the serial port does not
receive the guide data or the network port has no data within the set time, and the device will automatically disconnect.
When the short connection function is on, the short connection time is (2-255) seconds.

3.6.5 Connect the empty cache function

The device is in client mode, and when the TCP connection is not established, the data received by the serial port will be