Set Range Sorting Method: >Lm,Sr,X*<Cs><Cr - Safran LRF 6742 Manual

Table of Contents

Advertisement

LRF 6742 Integrator Manual
8.7.10 Set Range Sorting Method: >LM,Sr,x*<CS><CR>
This command sets the sorting method to range measurement commands.
The parameter x can take the following values:
 x=0  sort by signal strength (default setting, strongest target first)
 x=1  sort by range descending (farthest target first)
 x=2  sort by range ascending (closest target first)
The sorting method selected is permanently stored in memory.
Set Range Sorting Method command and response
Command
Inputs
>LM,Sr,x*<CS><CR>
>LM,Sr,0*E6<0D>
Response
Outputs
Example of a Set Range Sorting Method command transaction:
Host  LRF Module
Command frame:
LRF Module  Host
Acknowledge frame:
Prompt
INTEGRATOR MANUAL LRF 6742 918574A
Confidential & Proprietary  SAFRAN VECTRONIX AG – All rights reserved
Description
Set range sorting method for all range relevant commands.
Example with parameter 0.
Description
No response expected.
Table 3: Set Range Sorting Method
>LM,Sr,1*E7<0D>
>AC*84<0D>
<
Public: 04.2023
Page: 51/63