9. Calibration

With this menu, you can calibrate the device's colors.
01) While in main menu, press the UP/DOWN buttons to choose CALIBRATION. C.
02) Press the ENTER button to open the menu.
03) Insert the password in order to access the menu. Press the buttons in the following order:
UP,DOWN,UP,DOWN and press the ENTER button to confirm.
04) Press the UP/DOWN buttons to toggle through WHITE (white color calibration), CALIBRATION.R (reset
default settings white colors) and RGB TO W (RGBW calibration).

9.1. White Color Calibration

With this menu you can adjust the temperature of the built-in white color presets.
01) If you have chosen WHITE, press the ENTER button to open the menu.
02) Press the UP/DOWN buttons to choose one of the 13 white color presets: 2700K–10000K.
03) Once you have chosen the desired preset, press the ENTER button to open the submenu.
04) Press the UP/DOWN buttons to toggle through RED, GREEN, BLUE and WHITE.
05) Press the ENTER button to enter the desired color.
06) Press the UP/DOWN buttons to increase/decrease the intensity of the chosen color. The adjustment
range of each color is between 0-255, from OFF to FULL ON.

9.2. Reset White Color Calibration

With this menu you can reset the white colors to default settings.
01) If you have chosen CALIBRATION.R, press the ENTER button to open the menu.
02) Insert the password in order to access the menu. Press the buttons in the following order:
UP,DOWN,UP,DOWN and press the ENTER button to confirm.
03) When the process is finished, the display will show OK. The white colors will be set to default settings.

9.3. RGBW Calibration

With this menu you can adjust the temperature of the white color by means of RGB colors.
01) If you have chosen RGB TO W, press the ENTER button to open the menu.
02) Press the UP/DOWN buttons to toggle through RED, GREEN and BLUE.
03) Once you have chosen the desired color, press the ENTER button to edit.
04) Press the UP/DOWN buttons to set the color intensity. The adjustment range is between 0-255, OFF to
FULL ON.