SHOWTEC City Painter 9000 LED Manual
SHOWTEC City Painter 9000 LED Manual

SHOWTEC City Painter 9000 LED Manual

Wahers outdoors

Advertisement

MANUAL
ENGLISH
City Painter 9000 LED
V1
Ordercode: 40910
Highlite International B.V. – Vestastraat 2 – 6468 EX – Kerkrade – the Netherlands

Advertisement

Table of Contents
loading

Summary of Contents for SHOWTEC City Painter 9000 LED

  • Page 1 MANUAL ENGLISH City Painter 9000 LED Ordercode: 40910 Highlite International B.V. – Vestastraat 2 – 6468 EX – Kerkrade – the Netherlands...
  • Page 2: Table Of Contents

    Installation ................................... 9 Set Up and Operation ............................... 9 Control Modes ................................9 One City Painter 9000 LED (Static colors and Auto Mode) ................10 Multiple City Painters 9000 LED (Master/Slave control) ..................10 Multiple City Painters 9000 LED (DMX Control) ....................11 Fixture Linking ................................12...
  • Page 3: Ordercode: 40910

    City Painter 9000 LED Product Specifications ..............................27 Dimensions ..................................28 Notes ....................................29 Ordercode: 40910...
  • Page 4: Warning

    City Painter 9000 LED Warning Unpacking Instructions Immediately upon receiving this product, carefully unpack the carton and check the contents to ensure that all parts are present, and have been received in good condition. Notify the dealer immediately and retain packing material for inspection if any parts appear damaged from shipping or the carton itself shows signs of mishandling.
  • Page 5 • If your Showtec device fails to work properly, discontinue the use immediately. Pack the unit securely (preferably in the original packing material), and return it to your Showtec dealer for service.
  • Page 6: Operating Determinations

    Always let the installation be carried out by an authorized dealer ! Procedure: • If the City Painter 9000 LED is lowered from the ceiling or high joists, professional trussing systems have to be used. • Use a clamp to mount the City Painter 9000 LED, with the mounting bracket, to the trussing system.
  • Page 7: Connection With The Mains

    City Painter 9000 LED The City Painter 9000 LED can be placed on a flat surface or mounted to any kind of truss with a clamp. Improper installation can cause serious injuries and/or damage of property! Connection with the mains Connect the device to the mains with the power-plug.
  • Page 8: Return Procedure

    City Painter 9000 LED Return Procedure Returned merchandise must be sent prepaid and in the original packing, call tags will not be issued. Package must be clearly labeled with a Return Authorization Number (RMA number). Products returned without an RMA number will be refused. Highlite will not accept the returned goods or any responsibility.
  • Page 9: Description Of The Device

    City Painter 9000 LED Description of the device Features The Showtec City Painter 9000 LED is an extremely bright LED based fixture, powerful enough to illuminate large architectrural facades or entire stage areas.  High Lightoutput  RGBWA colormixing ...
  • Page 10: Overview

    04) 4-digit LED display + menu buttons Installation Remove all packing materials from the City Painter 9000 LED. Check if all foam and plastic padding is removed. Connect all cables. Do not supply power before the whole system is set up and connected properly.
  • Page 11: One City Painter 9000 Led (Static Colors And Auto Mode)

    City Painter 9000 LED One City Painter 9000 LED (Static colors and Auto Mode) 01) Place the effect light on a flat surface. Leave at least 0,5 meter on all sides for air circulation. 02) Plug the end of the electric mains power cord into a proper electric power supply socket.
  • Page 12: Multiple City Painters 9000 Led (Dmx Control)

    City Painter 9000 LED Multiple City Painters 9000 LED (DMX Control) 01) Place the effect light on a flat surface. Leave at least 0,5 meter on all sides for air circulation. 02) Use a 3-pin XLR cable to connect the City Painters and other devices.
  • Page 13: Fixture Linking

    43612) or the included special 3-pin to DMX IN / 3-pin to DMX OUT cables to connect with regular DMX data cables. The City Painter 9000 LED can be operated with a controller in control mode or without the controller in stand-alone mode.
  • Page 14: Control Panel

    City Painter 9000 LED Control Panel A) LED display MENU button C) SET button D) UP button DOWN button Fig. 04 Control Mode The fixtures are individually addressed on a data-link and connected to the controller. The fixtures respond to the DMX signal from the controller. (When you select the DMX address and save it, the controller will display the saved DMX address, next time.)
  • Page 15: Menu Overview

    City Painter 9000 LED Menu Overview Ordercode: 40910...
  • Page 16 City Painter 9000 LED Ordercode: 40910...
  • Page 17: Main Menu Options

    City Painter 9000 LED Main Menu Options Manual Mode (Static Color Mode) Built-in and custom programs Mode DMX address Master/ slave mode DMX configuration Settings Edit mode Calibration menu 1 Calibration menu 2 Optional Wireless DMX mode Keylock mode 1. Static Colors With this menu you can set the static colors.
  • Page 18: Built-In And Custom Programs

    City Painter 9000 LED 2. Built-in and custom programs With this menu you can set the built-in programs or choose your edited custom programs. 01) Press the MENU button on the device until the display shows 02) Press the SET button to open the menu.
  • Page 19: Settings

    City Painter 9000 LED 01) Press the MENU button until the display shows 02) Press the SET button to open the menu. 03) Press the UP/DOWN buttons to toggle between the following DMX channel modes: TOUR: 11 channels AR3.S: 7 channels ARC.1:...
  • Page 20: Color

    City Painter 9000 LED 6.4 Color With this menu you can adjust the color calibration functions. 01) Press the UP/DOWN buttons until the display shows 02) Press the SET button to open the menu. 03) Press the UP/DOWN buttons to toggle between the following 3 options:...
  • Page 21: How To Make Your Own Custom Program

    City Painter 9000 LED 7.1. How to make your own custom program 01) First, start with PR.01 and add the desired settings in scene 1 (SC.01), then scene 2 (SC.02) , etc. 02) In this way you can add a maximum of 30 scenes.
  • Page 22: Dmx Channels

    City Painter 9000 LED DMX Channels 11 channels TOUR Channel 1 – Master Dimmer intensity 0-255 Gradual adjustment, f rom dark to brightest 0-100% Channel 2 – Red Dimmer intensity (CH1 must be set between 001-255 0-255 Gradual adjustment Red from 0 – 100% Channel 3 –...
  • Page 23: Channels Arc.1

    City Painter 9000 LED Channel 9 – Auto program and Custom programs (CH1 must be set between 001-255 0-40 No function 41-50 AUTO01 51-60 AUTO02 61-70 AUTO03 71-80 AUTO04 81-90 AUTO05 91-100 AUTO06 101-110 AUTO07 111-120 AUTO08 121-130 AUTO09 131-140...
  • Page 24: Channels Ar1.D

    City Painter 9000 LED 4 channels AR1.D Channel 1 – Master Dimmer intensity 0-255 Gradual adjustment, f rom dark to brightest 0-100% Channel 2 – Red Dimmer intensity (CH1 must be set between 001-255 0-255 Gradual adjustment Red from 0 – 100% Channel 3 –...
  • Page 25: Channels Ar3.S

    City Painter 9000 LED 7 channels AR3.S Channel 1 – Master Dimmer intensity 0-255 Gradual adjustment, f rom dark to brightest 0-100% Channel 2 – Red Dimmer intensity (CH1 must be set between 001-255 0-255 Gradual adjustment Red from 0 – 100% Channel 3 –...
  • Page 26: Maintenance

    03) If all of the above appears to be O.K., plug the unit in again. 04) If you are unable to determine the cause of the problem, do not open the City Painter 9000 LED, as this may damage the unit and the warranty will become void.
  • Page 27 City Painter 9000 LED Problem Probable cause(s) Solution No power to the fixture • Check if power is switched on and One or more cables are plugged in fixtures do not function at all Fixtures reset The controller is not connected.
  • Page 28: Product Specifications

    City Painter 9000 LED Product Specifications Model: Showtec City Painter 9000 LED Input Voltage: 100-240V, 50/60Hz Power consumption: 300W max (full output) DMX linking: 30pcs Dimensions: 784 x 252 x 310 mm (LxWxH) Weight: 24,0 kg Operating and Programming: Signal pin OUT:...
  • Page 29: Dimensions

    City Painter 9000 LED Dimensions Weight flightcase: 17 kg Ordercode: 40910...
  • Page 30: Notes

    City Painter 9000 LED Notes Ordercode: 40910...
  • Page 31 City Painter 9000 LED Ordercode: 40910...
  • Page 32 ©2016 Showtec...

This manual is also suitable for:

40910

Table of Contents