During the POST (Power-On Self-Test) routines, which are performed each time
the system is powered on, errors may occur.
Non-fatal errors are those which, in most cases, allow the system to continue the
boot-up process. The error messages normally appear on the screen.
Fatal errors are those which will not allow the system to continue the boot-up
procedure. If a fatal error occurs, you should consult with your system manufacturer
for possible repairs.
These fatal errors are usually communicated through a series of audible beeps. The
numbers on the fatal error list (on the following page) correspond to the number
of beeps for the corresponding error. All errors listed, with the exception of Beep
Code 8, are fatal errors.
A-1 AMIBIOS Error Beep Codes
Beep Code
Error Message
1 beep
Refresh
5 short beeps and 1
Memory error
long beep
5 beeps
No Con-In or No
Con-Out devices
1 beep per device
Refresh
1 continuous beep
System overheat
Appendix A
BIOS Error Beep Codes
Description
Circuits have been reset (Ready to power up)
No memory detected in the system
Con-In: USB or PS/2 keyboard, PCI or Serial Console
Redirection, IPMI KVM or SOL
Con-Out: Video Controller, PCI or Serial Console Redirection,
IPMI SOL
1 beep for each USB device
X9 IPMI Error Codes
System overheat