Appendix D - ADM Event and Error Codes Overview
Error
Code
Error Name
Error Description
Invalid
The requested controlling
WSC0
Setpoint
value (pressure or flow) is
Request
outside the limits of the system
The shot that was entered for
Invalid Gel
the gel timer is not a valid shot.
WSD0
Timer
This must be fixed before the
Definition
gel timer will function properly
70
Error
Type
Cause
System incorrectly setup
Deviation
Shot incorrectly defined
Gel timer shot is below
the minimum dispense
amount or set for a
invalid pressure/flow
The MCM has
Deviation
determined that the gel
timer shot will not be able
to be executed based
parameters entered in
the ADM
Solution
On the ADM go into the setup screens -> System->
and ensure that all pages have properly defined
values
Redefine shot with control parameters within the limits
of the system
Select a different shot or modify existing shot data
If you are certain that the shot is within parameters,
try running the Learn Mode routine found in the setup
screen Calibration. If the error persists, a gel shot with
reduced control parameters is required.