Graco VRM Instructions Manual page 54

Hydraulic, plural-component, variable-ratio proportioner
Table of Contents

Advertisement

Appendix B - ADM Setup Screens Overview
Conditioning #3
NOTE: The VRM does not use Night mode conditioning.
Do not enable night mode.
This screen allows the user to configure Night Mode
operation. In Night Mode, the system will cycle on and
off periodically to maintain fluid temperature.
When the system is in Night Mode and in an "On" cycle,
the system will circulate in low pressure. The installed
conditioning zones will be on and controlling to their
respective setpoints.
When the system is in Night Mode and in an "Off" cycle,
the system will be idle. The system will not be circulat-
ing, and the conditioning zones will not be actively con-
trolling temperature.
Advanced #1
This screen allows the user to set the language, date
format, current date, time, setup screens password,
screen saver delay, and turn on or off silent mode.
54
Advanced #2
This screen allows the user to set the units of measure.
Advanced #3
This screen allows the user to control the availability of
some key system features.
Disable Dispensing From Display: Check this box
to disable dispensing from the ADM. A footswitch,
dispense valve trigger, or other external signal will
be the only way to initiate a dispense.
Disable Modifying Temp Setpoint: Check this box
to disable modifying temperature setpoints from the
Run screens. This is only applicable if temperature
control items are installed and enabled.
Disable Operator Mode Adjustments: When this
box is checked, the user will not be able to adjust
the dispense settings in Operator Mode.
Low Heater Temp Disables Dispense: When this
box is checked, the system will reject dispense
requests when any enabled heat zones are below
their setpoint.
High Chiller Temp Disables Dispense: When this
box is checked, the system will disable dispensing
when any enabled chiller zones are above their set-
point.
313873C