Main work
–
Position the motorcycle upright.
–
Place an appropriate container under the water pump cover.
–
1
Remove screw
–
Completely drain the coolant.
–
Mount and tighten screw
Guideline
Coolant drain plug
S04351-11
–
Completely fill the radiator with coolant.
Coolant (
p. 117)
–
3
Loosen screw
–
Mount and tighten screw
Guideline
Screw, radiator bleed-
ing
–
Mount radiator cap
Danger
V00870-10
Danger of poisoning Exhaust gases are toxic and inhaling
them may result in unconsciousness and death.
–
Always make sure there is sufficient ventilation when
running the engine.
–
Use effective exhaust extraction when starting or run-
ning the engine in an enclosed space.
–
Allow the engine to warm up and cool down again.
–
Check the coolant level. (
Finishing work
–
Check the cooling system for leaks.
COOLING SYSTEM 14
2
. Take off radiator cap
.
1
with a new seal ring.
M6
8 Nm (5.9 lbf ft)
until coolant escapes without bubbles.
3
.
M6
8 Nm (5.9 lbf ft)
2
.
p. 88)
91