Optional 4-Sided Faceplate Installation - Regency Fireplace Products Panorama P33CE Series Owners & Installation Manual

Zero clearance direct vent gas fireplace
Table of Contents

Advertisement

installation
|
40

OPTIONAL 4-SIDED FACEPLATE INSTALLATION

If installing the optional faceplate ensure the combustible
and non combustible material around the unit are installed
flush with the unit. (See Diagram 1 below).
The faceplate cannot be installed if materials are not flush.
Combustible
Material
Non-combustible Material (3-1/2" x 36")
Nailing Strip -1/2" back from unit face
Combustible
Material
Diagram 1- Materials flush w/unit.
1. Install 2 middle screws on unit face - do not tighten. Slide
bracket over screws then tighten. Install 2 outer screws .
Diagram 2 -Bracket screw locations on unit.
2. Install four (4) wood screws, two (2) on each side of the
bracket into the wall studs as shown below.
Diagram 3 -Bracket screw locations.
40 |
P33CE-10 Direct Vent Gas Fireplace
Install middle 2 screws on
to unit first
3. Line up the middle rib on backside of faceplate with middle indent on bracket.
This will centre the faceplate and allow 1/16" adjustment from side to side.
Diagram 4 -Line up faceplate and bracket.
4. Lift faceplate up and lower gently onto bracket.
Diagram 5 -Hang faceplate on bracket
Diagram 6 -Final Install
Middle Rib on Faceplate

Advertisement

Table of Contents
loading

This manual is also suitable for:

Panorama 3ce-ng10Panorama 3ce-lp10