maintenance
|
52
REMOVING VALVE
1. Shut off the gas supply.
2. Remove the safety screen and flush glass door–see instructions in
manual.
3. Remove the burner/grate assembly by removing the two screws
and then lift the burner assembly out.
Diagram 1: Remove the left and right screws and then lift out the
burner/grate assembly.
4. Remove the rear log stand by removing the 2 screws.
screws
5. Disconnect the inlet gas line.
6. Disconnect the EV1, EV2, and ground wires from the valve - as shown below.
Diagram 3
52 |
P33CE-10 Direct Vent Gas Fireplace
Rear Log Stand
Ground
Diagram 2
EV1
EV2
7. Remove the 12 screws securing the valve tray assembly in place
(Diagram 4) and then lift the entire assembly out.
Diagram 4 Valve Tray Assembly
8. Remove valve tray assembly.
Diagram 5: Lift out Valve Tray Assembly
INSTALLING VALVE
1. Install new valve assembly.
2. Reverse steps 7-1.