Electrical System - Follett L78614 Installation, Operation And Service Manual

Ice and water dispensers
Table of Contents

Advertisement

Access to electrical box and control board
The 12 series electrical box has been designed to slide out for easy access to the control board and more
convenient troubleshooting.
1. Remove top and front panels of dispenser
(for panel removal instructions see page 12).
2. Remove electrical box cover.
3. Pull electrical box toward front of unit.

Electrical system

ATTENTION!
To prevent circuit breaker overload, wait 15 minutes before restarting this unit. This allows the
compressor to equalize and the evaporator to thaw.
Normal control board operation
The PC board indicator lights provide all the information necessary to determine the machine's status. Green
indicator lights generally represent "go" or normal operation; Yellow indicators represent normal off conditions; Red
indicators generally represent alarm conditions, some of which will lock the machine off.
A flashing green light labeled POWER indicates power to the machine. All other normal operation status indicators
are covered as follows:
Ice machine disposition
Legend:
ON
1.
Ice machine is making ice.
2. Ice machine is not making ice.
18
12CI425A, 12HI425A
Operating conditions
OFF
ON or OFF
1.
2. Normal time delay. When the bin fills with ice, the LOW BIN
Fig. 16
electrical box
electrical
cover
FLASHING
Normal running.
light goes out momentarily and the refrigeration and auger
drive systems immediately shut down. (Note: The fan motor
will continue to run for 10 minutes to cool condenser) The TIME
DELAY light comes on, initiating the time delay period. When
the time delay expires, the machine will restart provided that the
LOW BIN light is on.

Advertisement

Table of Contents
loading