Diagnostic Stages - Follett L78614 Installation, Operation And Service Manual

Ice and water dispensers
Table of Contents

Advertisement

Start
Relay
Capacitor
OR
YELLOW
Water Sensors

Diagnostic stages

High gearmotor amps – Stage 1
The HI AMPS error and TIME DELAY LEDs are on indicating that the control board has sensed an over-torque
condition at the P4 terminal (more than 3 amps from the gearmotor) or no current draw (0A) and shut the ice
machine down (strike one). The HI AMPS and TIME DELAY LEDs will remain on for 60 minutes after an over-
torque condition has occurred. The ice machine will remain off as long as these two LEDs are on. After the
60 minute time delay, these LED lights turn off, and the control board will try to go through a normal start-up
sequence.
Start
Capacitor
Relay
OR
YELLOW
A B C D
Water Sensors
T.O.L.
R
S
C
Compressor
2
RED
Start
Relay
5
Compressor
Electrical Box
WHITE
Drain
Fill
4
Valve
Valve
3
2
BLACK
R
S
C
Gearmotor
A B C D
T.O.L.
R
S
C
Compressor
2
1
RED
Start
Relay
5
Compressor
Electrical Box
WHITE
Drain
Fill
4
Valve
Valve
3
2
BLACK
R
S
C
Gearmotor
Fan
1
WHITE
N
L1
L1
RED
P6
P21
BROWN
P20
P19
BLACK
P3
P22
BLUE
AUGER
Bin T-Stat
Fan
WHITE
N
N
L1
L1
RED
P6
P21
P20
BROWN
P19
BLACK
P3
P22
BLUE
AUGER
Bin T-Stat
High
Pressure
Switch
POWER
N
P15
LOW BIN
BLACK
MAKING ICE
SLEEP CYCLE
HI PRS
TIME DELAY
1 2 3 4 5 6 7 8
LOW WATER
MAINTENANCE
RESET
SERVICE
HI AMPS
WATER LEVELS
HI PRESSURE
P11
BIN
P4
CLEANER FULL
Clean Switch
High
Pressure
Switch
POWER
P15
LOW BIN
BLACK
MAKING ICE
SLEEP CYCLE
HI PRS
TIME DELAY
LOW WATER
1 2 3 4 5 6 7 8
MAINTENANCE
RESET
SERVICE
HI AMPS
WATER LEVELS
HI PRESSURE
BIN
P11
P4
CLEANER FULL
Clean Switch
12CI425A, 12HI425A
29

Advertisement

Table of Contents
loading

Table of Contents