B. Gas Distribution
The single gas used is internally split into plasma
and secondary gases.
The plasma gas flows into the torch through
the negative lead, through the starter cartridge,
around the electrode, and out through the tip
orifice.
The secondary gas flows down around the outside
of the torch starter cartridge, and out between the
tip and shield cup around the plasma arc.
C. Pilot Arc
When the torch is started a pilot arc is established
between the electrode and cutting tip. This pilot
arc creates a path for the main arc to transfer to
the work.
D. Main Cutting Arc
DC power is also used for the main cutting arc.
The negative output is connected to the torch
electrode through the torch lead. The positive
output is connected to the workpiece via the work
cable and to the torch through a pilot wire.
Manual 0-5404
All manuals and user guides at all-guides.com
INTRODUCTION
ESAB CuTmASTEr 100
E. Parts - In - Place (PIP)
The torch includes a 'Parts - In - Place' (PIP) cir-
cuit. When the shield cup is properly installed, it
closes a switch. The torch will not operate if this
switch is open.
Torch Switch
To Control
Cable Wiring
PIP Switch
A-02997
Parts - In - Place Circuit Diagram for Hand Torch
Remote Pendant
PIP Switch
To ATC
CNC Start
PIP Switch
To ATC
Automation Torch
PIP Switch
To ATC
Parts - In - Place Circuit Diagram for Machine Torch
Torch Trigger
Shield Cup
Shield Cup
Shield Cup
Shield Cup
2T-3