ESAB Cutmaster 100 Operating Manual page 42

Plasma cutting system
Hide thumbs Also See for Cutmaster 100:
Table of Contents

Advertisement

ESAB CuTmASTEr 100
Type Torch: SL100 With Shielded Tip
Type Plasma Gas: Air
Thickness
Tip
Output
Inches mm
(Cat. No.)
Volts(VDC)
0.060 1.5
9-8211
128
0.120 3.0
9-8211
126
0.135 3.4
9-8211
128
0.188 4.8
9-8211
128
0.250 6.4
9-8211
131
0.375 9.5
9-8211
134
0.500 12.7
9-8211
136
0.625 15.9
9-8211
145
0.750 19.1
9-8211
144
0.875 22.2
9-8211
149
1.000 25.4
9-8211
162
Type Torch: SL100 With Shielded Tip
Type Plasma Gas: Air
Thickness
Tip
Output
Inches mm (Cat. No.) Volts(VDC)
0.060 1.5
9-8211
110
0.120 3.0
9-8211
115
0.135 3.4
9-8211
113
0.188 4.8
9-8211
114
0.250 6.4
9-8211
116
0.375 9.5
9-8211
123
0.500 12.7 9-8211
133
0.625 15.9 9-8211
135
0.750 19.1 9-8211
144
0.875 22.2 9-8211
137
1.000 25.4 9-8211
140
Type Torch: SL100 With Shielded Tip
Type Plasma Gas: Air
Thickness
Tip
Output
Inches
mm (Cat. No.) Volts(VDC)
0.06
1.5
9-8211
115
0.12
3.0
9-8211
120
0.188 4.8
9-8211
120
0.250 6.4
9-8211
124
0.375 9.5
9-8211
138
0.500 12.7 9-8211
141
0.625 15.9 9-8211
142
0.750 19.1 9-8211
150
0.875 22.2 9-8211
156
1.000 25.4 9-8211
164
4T-16
All manuals and user guides at all-guides.com
Amperage Speed (Per Minute)
Standoff
(Amps)
Inches
Meters
Inches
80
280
7.11
0.19
80
203
5.16
0.19
80
182
4.62
0.19
80
137
3.48
0.19
80
100
2.54
0.19
80
40
1.02
0.19
80
36
0.91
0.19
80
21
0.53
0.19
80
14
0.36
0.19
80
11
0.28
0.19
80
8
0.20
0.19
Amperage Speed (Per Minute)
Standoff
(Amps)
Inches
Meters
Inches mm
80
340
8.50
0.125 3.2
80
260
6.50
0.125 3.2
80
250
6.25
0.125 3.2
80
170
4.25
0.125 3.2
80
85
2.13
0.125 3.2
80
45
1.13
0.125 3.2
80
18
0.45
0.125 3.2
80
16
0.40
0.125 3.2
80
8
0.20
0.125 3.2
80
8
0.20
0.125 3.2
80
8
0.20
0.125 3.2
Amperage Speed (Per Minute)
Standoff
(Amps)
Inches
Meters
Inches mm
80
320
8.13
0.13
80
240
6.10
0.13
80
165
4.19
0.13
80
100
2.54
0.13
80
60
1.52
0.19
80
36
0.91
0.19
80
26
0.66
0.19
80
18
0.46
0.19
80
8
0.20
0.19
80
6
0.15
0.19
OPERATION
Type Material: Mild Steel
Type Secondary Gas: Single Gas Torch
Plasma Gas Press
Flow (CFH)
mm
psi*
bar
Plasma Total** Delay (Sec) Inches mm
4.8
65
4.5
115
340
4.8
65
4.5
115
340
4.8
65
4.5
115
340
4.8
65
4.5
115
340
4.8
65
4.5
115
340
4.8
65
4.5
115
340
4.8
65
4.5
115
340
4.8
65
4.5
115
340
4.8
65
4.5
115
340
4.8
65
4.5
115
340
4.8
65
4.5
115
340
Type Material: Stainless Steel
Type Secondary Gas: Single Gas Torch
Plasma Gas Press
Flow (CFH)
psi*
bar
Plasma Total** Delay (Sec) Inches
65
4.5
115
340
65
4.5
115
340
65
4.5
115
340
65
4.5
115
340
65
4.5
115
340
65
4.5
115
340
65
4.5
115
340
65
4.5
115
340
65
4.5
115
340
65
4.5
115
340
65
4.5
115
340
Type Material: Aluminum
Type Secondary Gas: Single Gas Torch
Plasma Gas Press
Flow (CFH)
psi*
bar
Plasma Total** Delay (Sec) Inches mm
3.2
65
4.5
115
340
3.2
65
4.5
115
340
3.2
65
4.5
115
340
3.2
65
4.5
115
340
4.8
65
4.5
115
340
4.8
65
4.5
115
340
4.8
65
4.5
115
340
4.8
65
4.5
115
340
4.8
65
4.5
115
340
4.8
65
4.5
115
340
Pierce
Pierce Height
0.00
0.2
5.1
0.10
0.2
5.1
0.10
0.2
5.1
0.20
0.2
5.1
0.30
0.2
5.1
0.50
0.2
5.1
0.60
0.2
5.1
0.75
0.2
5.1
NR
NR
NR
NR
NR
NR
NR
NR
NR
Pierce
Pierce Height
mm
0.00
0.2
5.1
0.10
0.2
5.1
0.10
0.2
5.1
0.20
0.2
5.1
0.30
0.2
5.1
0.40
0.25
6.4
0.75
0.25
6.4
1.00
0.25
6.4
NR
NR
NR
NR
NR
NR
NR
NR
NR
Pierce
Pierce Height
0.00
0.25
6.4
0.10
0.25
6.4
0.20
0.25
6.4
0.30
0.25
6.4
0.40
0.25
6.4
0.60
0.25
6.4
0.75
0.25
6.4
NR
NR
NR
NR
NR
NR
NR
NR
NR
Manual 0-5404

Advertisement

Table of Contents
loading

Table of Contents