Bosch SCT 815 S5 Original Operating Instructions page 15

Adjustment device
Table of Contents

Advertisement

1 m
4712008-12_shd
(1) Area where SCT 815 S5/S6 is set up
(2) SCT 815 S5/S6 resting surface (example)
---
Calibration environment
Metallic objects interfere with front radar sensor
calibration.
• The area between the vehicle and SCT 815 S5/S6
must not contain metallic any objects.
• The area within a radius of 2 m around
SCT 815 S5/S6 must not contain any metallic ob‐
jects.
4712008-12_shd
1
(1) Manufacturer-specific area between the vehicle and
SCT 815 S5/S6 (see brief instructions)
(2) Area around SCT 815 S5/S6
(3) SCT 815 S5/S6
---
Diagnostic software
• Diagnostic software for calibrating the front radar
sensor
• If [ESI]tronic 2.0 is used as diagnostic software: info
type SD (control unit diagnosis) and KTS
---
2.5
Laser range finder GLM 100-25 C
Only GLM 100-25 C may be used as a laser range
finder for aligning SCT 815 S5/S6.
The laser range finder GLM 100-25 C is used to posi‐
tion SCT 815 S5/S6 in front of the vehicle and to adjust
the height of the prismatic reflector.
The following properties of the laser range finder
GLM 100-25 C ensure that SCT 815 S5/S6 can be posi‐
tioned precisely as specified in the brief instructions
specific to the vehicle:
• Continuous distance measurement
• Display of inclination angle
• Rear edge as reference point for distance measure‐
ment
---
Robert Bosch GmbH
5 m
1
2
3
2
2.6
Functional description
The front radar sensor for the makes Mazda, Honda,
Toyota, Kia and Hyundai must be calibrated using a
prismatic reflector. For the front radar sensor to be
calibrated, the prismatic reflector must be positioned
in front of the vehicle at a distance and height specific
to that vehicle. The adjustment device SCT 815 S5/S6
is used to put the prismatic reflector in that vehicle-
specific position.
As soon as the prismatic reflector is in its vehicle-spe‐
cific position, the calibration must be started using di‐
agnostic software. The front radar sensor emits signals
focused and reflected back to the front radar sensor by
the prismatic reflector. The calibration will be success‐
ful if the prismatic reflector is precisely aligned. The
calibration may fail if the prismatic reflector is not pre‐
cisely aligned or the measurement bay requirements
are not met.
---
3.
Initial commissioning
3.1
---
SCT 815 S5/S6 installation
1. Make sure all components specified in the scope of
delivery are present.
2. Position the guide tubes with the tube connectors
(1)
over the holes in the base plate.
4 Nm
1 1
3
4
2
(1) Guide tube with tube connectors
(2) Base plate
(3) Hex socket head cap screw
(4) Washer
3. Use the hex socket head cap screws
(4)
to secure the tube connectors on the base plate
at 4 Nm.
4. Slide the preassembled tool holder
guide tubes, and use the knurled screw
it.
SCT 815 S5/S6 | 15 | en
(3)
and washers
(1)
onto the
(2)
to secure
1 689 989 475 | 2023-06-28