5.2 Combining units and options
5.2.1 Possible combinations of indoor unit and outdoor unit
5.2.2 Possible options for the outdoor unit
5.2.3 Possible options for the indoor unit
ERLA03DAV3 + EHFZ03S18DJ3V
Daikin Altherma 3 R F
4P596821-1B – 2021.10
Model identification
Example: E HF Z 03 S 18 DJ 3V
Code
E
European model
HF
Floor-standing indoor unit with integrated tank
Z
Dual-zone model
03
Capacity class
S
Integrated tank material: Stainless steel
18
Integrated tank volume
DJ
Model series
3V
Backup heater model
INFORMATION
Certain options may NOT be available in your country.
Outdoor unit
ERLA03DAV3
Bottom plate heater (EKBPHT03D)
▪
Prevents freeze-up of the bottom plate.
▪
Recommended in areas with low ambient temperature and high humidity.
▪
Required in areas with ambient temperatures between –7°C and –15°C when the
outdoor unit is installed between 1000 m and 2000 m altitude. See
"7.1.2 Additional installation site requirements of the outdoor unit in cold
4
climates" [
51] for more information.
▪
For installation instructions, see the installation manual of the bottom plate
heater.
User interface (EKRUDAL1)
A main user interface –required for operation– is delivered with the unit as
accessory. Additionally, an optional user interface can be connected to have both:
▪
Control close to the indoor unit (by the main user interface)
▪
Room thermostat functionality in the principal space to be heated (by the
optional user interface)
EKRUDAL1 contains following languages: English, French, Dutch, Italian.
5
About the units and options
|
Description
Indoor unit
EHFZ03S18DJ3V
O
Installer reference guide
27