To Connect The Domestic Hot Water Pump - Daikin EHFZ03S18DJ3V Installer's Reference Manual

Hide thumbs Also See for EHFZ03S18DJ3V:
Table of Contents

Advertisement

9.3.6 To connect the domestic hot water pump

ERLA03DAV3 + EHFZ03S18DJ3V
Daikin Altherma 3 R F
4P596821-1B – 2021.10
A
B
A
B
3 Fix the cable with cable ties to the cable tie mountings.
Wires: (2+GND)×0.75 mm²
DHW pump output. Maximum load: 2 A (inrush), 230 V AC, 1 A
(continuous)
[A.2.2] Options > [A.2.2.A] DHW pump
[7.3] Set schedules > [7.3.7] DHW pump
1 Open the following (see
1 Top panel
2 Upper front panel
3 Upper switch box cover
2 Connect the domestic hot water pump cable to the appropriate terminals as
shown in the illustration below.
S3S
S2S
3
4
5
6
3 4 5 6
"7.2.4 To open the indoor
9
Electrical installation
|
X5M
4
unit" [
 55]):
Installer reference guide
1
3
2
101

Advertisement

Table of Contents
loading

This manual is also suitable for:

Altherma 3 r fErla03dav3Erla-dvEhfz-d3v

Table of Contents