Table 2-1
Working Environment Requirements
Operating Temperature
-40° C to 65° C (-40° F to 149° F)

Waterproof Requirement

Seal the unused ports using the connector plugs or cable glands to ensure that the access point is watertight.
The cable glands must be used for all cables that are threaded through the ports to prevent exposing the
access point interior to environmental elements. See

Grounding Requirement

A proper grounding system is the basis for stable and reliable running and is indispensable for preventing
lightning strikes and interference. Carefully check the grounding conditions at the installation site according to
the grounding specifications, and complete grounding properly based on the actual situation.

Anti-interference Requirements

Keep the access point as far away from the lightning prevention equipment and grounding equipment of the
power device as possible.
Keep the access point far away from radio stations, radar stations, high-frequency high-current devices, and
microwave ovens.
2.3

Tools

Table 2-2
Tools
Common
Tools
Special Tools
Meters
Other Tools
Note
The tool kit is not included in the package contents. The tool kit is customer-supplied.
Phillips screwdriver, Hex screwdriver, power cords, Ethernet cables, fastening bolts,
diagonal plier, and binding straps
Anti-static wrist strip, wire stripper, crimping plier, wire cutter, waterproof tape
Multimeter
PC, display, and keyboard
Operating Humidity
0% to 100% RH (non-condensing)
Installing the Ethernet Cable