Chapter 3 Appendix
SNMP
1500
When installing an OS
Service Control Manager
7023
When installing an OS
Service Control Manager
7030
When installing an OS
Microsoft-Windows-
WinRM
10149
When installing an OS
Application Event Log
Microsoft-Windows-WMI
24
When applying Starter Pack or driver for
InfiniBand card for the first time after OS
installation
Microsoft-Windows-
Security-SPP
1014
When installing an OS
Microsoft-Windows-
Security-SPP
1015
When installing an OS
Microsoft-Windows-
Security-SPP
1058
When installing an OS
The SNMP Service encountered an error while accessing the registry
key
Error
SYSTEM\CurrentControlSet\Services\SNMP\Parameters\TrapConfigur
ation.
If this event is logged only when SNMP is enabled and does not occur
repeatedly, there is no problem with system operation.
Go to the following Microsoft website for details.
http://support.microsoft.com/kb/2002303/
The IP Helper service terminated with the following error:
Error
The service cannot be started, either because it is disabled or because
there are no enabled devices associated with it.
If this event is logged only when installing an OS and does not occur
repeatedly, there is no problem in system operation.
Printer Extensions and Notifications service is marked as interactive
Error
service. However, the system is not allowed to use interactive service.
Thus, this service might not work correctly.
If this event is logged only when installing an OS and does not occur
repeatedly, there is no problem in system operation.
Warning
The WinRM service is not listening for WS-Management requests.
If this event is logged together with ID 7036 "Service Control Manager
(Windows Remote Management (WS-Management) service has
stopped.), there is no problem in system operation.
Also, if WinRM event 10148 (WinRM service is listening
WS-Management requests.) is output immediately after this event, there
is no problem in system operation.
Event provider MLNXProvider attempted to register query "select * from
MLNX_NetAdapterStatusEvent" whose target class
Error
"MLNX_NetAdapterStatusEvent" in //./root/standardcimv2/mlnx
namespace does not exist. The query will be ignored.
This event does not affect system operation.
Failed to obtain end-user license.
Error
hr=0x80072EE7
If this event is logged only when installing an OS and does not occur
repeatedly, there is no problem in system operation.
Detailed information of HRESULT
Warning
Returned hr=0xC004F022, original hr=0x80049E00
If this event is logged only when installing an OS and does not occur
repeatedly, there is no problem in system operation.
Failed to obtain certificate of purchase from ACPI table.
Error
Error code: 0xC004F057
This event does not affect system operation.