NEC EXP803 Maintenance Manual page 191

Express server
Hide thumbs Also See for EXP803:
Table of Contents

Advertisement

Chapter 3 Appendix
(3) Error messages on a virtual LCD
You can confirm the error messages by the EXPRESSSCOPE Engine 3 web browser window. See
EXPRESSSCOPE Engine 3 User's Guide for details.
The table below shows the error messages displayed on upper and lower lines, cause, and solution.
Messages displayed on an upper LCD line
BIOS Message
on Upper LCD Line
XX POST Started...
XX BIOS Rev YYYY
POST Completed Successfully POST completes normally.
POST ERROR XXXX
No Available Memory in System No available memory is implemented.
Error Pause in POST
Entering BIOS SETUP MENU
Waiting for normal
temperature
BIOS Recovery Running
BIOS Updater Running
System Configuration change
is detected
PCI Bus System Error 1
PCI Bus Parity Error 1
CPUx_DIMMx Correctable Error
(x: DIMM number)
Memory DIMM Sparing Fail-over
on CPUx (x: CPU socket number)
Memory Mirroring Fail-over on
CPUx (x: socket number)
Cause
This message appears while POST is
running.
"XX" means a POST code in progress.
This message appears while POST is
running.
"XX" means a POST code in progress,
and "YYYY" means the system BIOS
version.
Error XXXX occurred during POST.
POST detected an error and paused.
Starting up BIOS SETUP MENU.
A temperature abnormality was
detected inside the server.
BIOS recovery is in progress.
BIOS update is in progress.
The CPU or memory configuration has
changed since the previous startup.
A system error was detected in PCI
bus.
A parity error was detected in PCI bus.
A frequent occurrence of correctable
memory error was detected.
Memory Sparing feature failed over to
standby memory.
Memory Mirroring feature failed over to
standby memory.
Express5800/R120f-1E Maintenance Guide
1. POST Error Message
Message displayed on
upper LCD line
Message sent from BIOS
Message displayed on lower
LCD line
Message sent from BMC
Solution
This is not an error.
Check the message displayed on LCD,
and take an appropriate action.
Make sure that the memory is correctly
implemented.
Check the message displayed on LCD,
and take an appropriate action.
This is not an error. This message will
disappear when SETUP operation is
completed.
Lower the room temperature or turn off
the power to cool the server to room
temperature before starting up the
server. If this abnormality continues to
occur, check if a fan has failed. If the
same error still continues to occur,
contact your representative.
This is not an error. Wait until BIOS
update is completed.
If this message appears even when no
configuration change has been made,
contact your sales representative
Contact your sales representative.
191