F1 Setting Of Out1 - SMC Networks ZSE10(F) Operation Manual

Digital pressure switch
Table of Contents

Advertisement

■[F 1] Setting of OUT1
Set output method of OUT1.
The output turns on when the pressure exceeds the set value. The default setting of the output set value is
the central value between the atmospheric pressure and the upper limit of the rated pressure range.
For the operation of each setting, refer to "List of output modes" on page 27.
<Operation>
Press the
or
button in function selection mode to display [F 1].
Select output mode
or
Press the
button to select output mode.
Press the
button to set.
Select reversed output
or
Press the
button
to select reversed output.
Press the
button to set.
Pressure Setting
Set the pressure based on the setting procedure on page 21.
"P" becomes "n" when reversed output is selected.
([P_1] → [n_1])
Hysteresis mode: [P_1]
Window comparator mode: [P1L][P1H]
Press the
button to set.
Press the
button.
Move on to setting of reversed
output.
Move on to setting of pressure.
Move on to setting of hysteresis.
-25-
Move on to setting of output mode.
[oFF] (unused) selected.
Press the
Move on to setting of display
colour.
button to set.
No.PS※※-OMM0005-J