APPENDIX B: 'PIECE BY PIECE' INSTALLATION
Removing the Top Motor/Fan Assembly:
The cooler electronics enclosure is located between the front
and RHS side panels.
Disconnect the exhaust motor communications and power and
remove all cables from the cable holders (holding the exhaust
motor and pump cables).
Remove the electronics enclosure splash cover.
ILL3114-A
Cable Clamps
ILL3117-A
Unclip the bottom tab.
Swing the cover out from the
bottom, then pull the cover
down to disengage the top tab
from the mount bracket slot.
ILL3132-A
Disconnect the cables labelled 'Top Motor' and 'Top Motor
Signal' from the control board ONLY.
CHLORINATOR
DRAIN
SOLENOID
COMMS
COMMS
ON / OFF
TOP
Remove any cable ties above the enclosure to free the 2 cables
to the top exhaust motor then free these cables. Remove the
single centre screw holding the electronics enclosure to the
mount plate.
Leave any remaining wires and hoses connected within the
electronics enclosure. Rest the electronics enclosure on the
tank in a drained and dry position.