INSTALLATION
For installations which require the power cable to pass down
the inside of the supply duct, guide the free end into the corner
recess slot on the transition and down into the supply duct.
Identify the white dropper transition straps which
protrude out from the tank. These straps are flared
outwards and should fall outside the edges of
the supply duct transition as the cooler is being
lowered.
Once fitted correctly, the white dropper transition straps should
align with the pre-drilled pilot holes in the supply duct. Some
transition straps may need to be pulled down to meet with pilot
holes in the supply duct.
14 |
859741-L CW3 INSTALLATION MANUAL
WARNING! BE EXTREMELY CAREFUL NOT TO TRAP
HANDS IN BETWEEN THE COOLER AND TRANSITION.
DO NOT POSITION ANY PART OF YOUR BODY
UNDERNEATH THE COOLER WHILE IT IS SUSPENDED BY
CRANE.
BE EXTREMELY CAREFUL NOT TO DAMAGE THE
TRANSITION STRAPS, COMMUNICATION OR MAINS
POWER CABLES.
ILL3036-B
Secure the cooler to the transition using the screws provided.
A total of twelve (12) screws are required. Only use the screws
provided.
ILL3030-A
ILL3125-A
ILL2786-A