Ricoh AP204 Operator's Manual page 102

Ricoh ap204: quick start
Table of Contents

Advertisement

Important
Exposing the photoconductor unit
to light for too long can reduce its
performance. Replace the unit as
quickly as possible.
Do not touch the surface of the
photoconductor unit. If you do, it
may damage the photoconductor
unit and reduce the print quality.
Do not expose the photoconductor
unit to a light source greater than
800 luxes for more than two min-
utes. If you do, the photoconductor
unit will be damaged and the print
quality might be reduced.
Note
Before removing the photo-
conductor unit from the printer,
spread paper or some other mate-
rial around the area you are work-
ing to keep toner from making floor
dirty.
Display of the "Change PCU" mes-
sage is based on a printed page
counter kept internally by the
printer. It is meant as a general
guide to photoconductor unit life
only. Actual photoconductor unit
life depends on the printing condi-
tions.
A
Make sure that the Data In indica-
tor is not lit or flashing, press the
printer's power switch to turn off
power.
B
Open the front cover by pulling
the front cover open lever and
open the top cover by pulling the
top cover open lever.
Important
Be sure to open both the top and
front cover before removing the
photoconductor unit. Failure to
do so can result in damage to the
surface of the photoconductor
unit.
C
Stand up the green lock levers to a
vertical position.
D
Hold the inset grip of the photo-
conductor unit, pull it straight up,
and remove it from the printer.