Dealing With Malfunctions - Nibe EMINENT E/CU/R 35 Installation And Maintenance Instructions Manual

Table of Contents

Advertisement

Available languages

Available languages

Dealing with malfunctions

NOTE!
Electrical installation and service must be
carried out under the supervision of a qual-
ified electrician.
If the power cable is damaged, in order to
prevent a hazard it must be replaced by the
manufacturer, its authorised service agent
or other qualified person.
Check the installation's fuses as well as the thermostat
and mixer valve settings.
Wait a few hours without tapping any hot water and
then check whether the temperature level has risen. If
there is still no hot water, contact the installation engi-
neer.
Resetting the temperature limiter
If the temperature limiter (5) tripped, the water heater
must cool for at least one hour before it can be reset.
1. Remove the plastic cover (2).
2. Press the button on the temperature limiter lightly,
max 15 N (approx. 1.5 kg).
5
6
Max 15 N (approx. 1.5 kg)
Reconnecting sensors
If the immersion heater has been replaced, the sensors
for the thermostat and temperature limiter must be re-
installed in the order displayed in the image.
2
Max. 15N
K
L E
K
L E
K
L E
K
L E
Service
For service, contact the installer. The serial number (95),
(14 digits) and installation date should always be stat-
ed. Only electrical equipment supplied by NIBE AB in
Markaryd may be used.
EMINENT
Maintenance
GB
17

Advertisement

Table of Contents
loading

This manual is also suitable for:

Eminent e/cu/r 55Eminent e/cu/r 100Eminent e/cu/r 120

Table of Contents