Download Print this page

Configuration Chart - Altronix T2RM7CK1 Installation Manual

Altronix/mercury wired rack kits

Advertisement

Altronix Trove Mercury rack kits are pre-assembled and consist of Trove enclosures/backplanes with factory installed Altronix power supply/charger
and sub-assemblies. All kits accommodate a variety of Mercury modules for up to eight doors in a single enclosure.
Altronix
Model
Number
T2RM7CK1
4.5
T2RM7CK1D
Wiring methods shall be in accordance with the National Electrical Code/NFPA 70/ANSI, and with all local codes and authorities having jurisdiction.
These products are for indoor use only and must be installed within the protected premises.
Note: First assemble and Install Z Bracket Wire Management Accesory (refer to Z Bracket Installation pg. 3)
1. Remove backplane from enclosure prior to installing into rack cabinet (do not discard hardware).
2. In order to mount included cUL Listed tamper switch (Tane Model 3/8 ASH FM WH or equivalent),
turn the enclosure upside down and locate mounting holes (Fig. 1, pg. 2).
Insert the tamper switch flying leads into the center knockout of the three (3) holes from outside of the
drawer with the button facing outwards, make sure tamper switch is inserted properly then secure it
with the two (2) screws (supplied). Connect tamper switch wiring to the Access Control Panel input or
the appropriate UL Listed reporting device. To activate alarm signal open the rack drawer.
3. Slide the rack enclosure into an open 2U location in the four post rack cabinet.
4. Utilizing proper fasteners attach front ears to the rack rails (Rack drawer, pg. 8).
5. Attach the rear of the adjustable slides to the rear rails of the rack cabinet with the proper fasteners.
6. Secure the rack cover (Fig. 2a, pg. 3) and rack drawer (Fig. 2b, pg. 3) to earth ground.
7. Ensure that all internal cofigurations (voltage selection, switch settings, etc.) are completed before
mounting backplane back into Trove rack enclosure.
Fig. 2
Fig. 2b
- 2 -

Configuration Chart:

Nominal DC
Output Voltage
[DC]
[Aux]
Output
Output
Range
Range
(VDC)
(VDC)
6.3A/
15A/
20.17-
20.28-
250V
32V
26.4
Installing Trove2R into Rack Tower:
Overview:
Maximum Supply
Current for Main
and Aux. Outputs on
Power Supply board
and ACMS8(CB)
Access Power
Controller's outputs
24VDC @ 9.2A
26.4
15A/
3A/
2.5
32V
32V
8
2.0
9A
2.5A
Fig. 1
Back of the drawer,
viewed from outside.
Tamper Switch
mounting location
Fig. 2a
10A/
3A/
32V
32V
9A
2.5A
T2RM7CK1(D) Installation Guide

Advertisement

loading

This manual is also suitable for:

T2rm7ck1d