6.

TECHNICAL DATA

HiArc
Connection voltage
Rated power at max. current
Supply current
Output 40 °C
Fuse (delayed)
Open circuit voltage
Power factor at 60%
Efficiency at 100%
Welding range
External dimensions
Weight
EMC class
Degree of protection
Gas heater connection
© Kemppi Oy / 1445
M 350A
3~, 50/60 Hz
380 V (-10%...+15%)
60% ED
14.3 kVA
100% ED
10 kVA
I
22 A
1max
I
17 A
1eff
60% ED
350 A / 31.5 V
100% ED
270 A / 27.5 V
20 A
50...60 V
0.88
87%
13...35 V
L x W x H
647 x 385 x 485 mm
36 kg
This product is classified as a Class A EMC
IP23S
36 V/150 W
M 500A
380 V (-10%...+15%)
24.5 kVA
17 kVA
37 A
29 A
500 A / 39.0 V
390 A / 33.5 V
35 A
60...70 V
0.92
87%
13...50 V
716 x 385 x 485 mm
41 kg
IP23S
36 V/150 W