Graco PR-Xv Instructions Manual page 34

Variable ratio metering system
Table of Contents

Advertisement

HMI Display Operation and Identification
Reload type setup
The selected reload type is showed as green color.
Reload after each job: In this mode, the metering
rods retract after every shot. This is the default
setup.
Reload after multi jobs: In this mode, the metering
rods retract only when the metering rods reach the
reload request position and the operator closes the
'Job Start' signal.
Custom signal reload: In this mode, the metering
rods retract only when the metering rods reach the
reload request position and the operator sends
'Reload' signal.
34
Purge Setup Screen
F
. 31 Purge Setup Screen
IG
On the Purge Setup Screen, press 'F1' or select
display the System Main Screen. Press 'F7' or select
to return to the previous screen. Press 'F8' or
select
to continue to the next screen.
The content and functions of this screen are as follows:
Auto purge setup
: This shows that auto purge is open.
That is, the system automatically starts to execute
purge after jobs. Click at this to disable auto purge.
: This shows that auto purge is closed.
The operator needs to execute manual purge. Click
at this to enable auto purge.