Powering On/Off The Various Scanner Operating Modes - Raymarine E120W Reference Manual

E-series networked display
Hide thumbs Also See for E120W:
Table of Contents

Advertisement

146

7.3 Powering on/off the various scanner operating modes

To control the power to the radar:
The scanner icon in the data bar indicates the chosen status and is described as:
Radar
Mode
Transmit
(TX)
Standby
(STDBY)
Off
Timed
transmit
Notes: (1) When an open array antenna is fitted, the system stops the antenna in
(2) Dual radar support will only allow one radar to be active at any one
SCANNER
SCANNER
ON
Switch scanner ON
or OFF
Radar status
Status description/use
icon
Scanner on and transmitting.
When SCANNER set to ON, select this mode to activate scan-
ner. This is the usual mode of operation
(Rotating icon)
Scanner on but not transmitting and antenna not
rotating.
Antenna does not rotate, the scanner does not transmit and
the radar data is removed from the screen. This is a power
(static icon)
save mode used when radar not needed for short time peri-
ods. When you return to transmit mode, the magnetron does
not need to warm up. This is the default mode.
Scanner powered off
When radar not required but display in use for other applica-
tions e.g. chart.
When selected, system countdowns - during this time you
(grayed-out icon)
cannot re-power the scanner.
Scanner switches between on/transmitting &
standby mode
Power save mode when constant use of radar not required.
To set up this option, see
(rotating/static icon)
the forward facing position when Standby mode is selected.
time. You cannot set up two radar windows, each using a different
scanner.
E-Series Networked Display Reference Manual
OFF
RADAR
TX
Select required
operating mode
page 170
.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

E80E120

Table of Contents