  • Page 1 Classroom Audio System  Classroom Audio System Installation and Operating Manual V 1.7...
  • Page 2 To protect your hearing, please avoid high pressure level on earphones. Adjust to a lower and convenient level. If any detailed information needed, please contact your local retailer or TAIDEN service center in your region.  Any feedback, advice and suggestion about the products are appreciated.
  • Page 3 TAIDEN Service Center. The apparatus should be connected to the MAINS 20. All TAIDEN products are guaranteed for definite time socket-outlet with protective earth. (see the WARRANTY CARD for details) excluding the Clean only with dry cloth.
  • Page 4 Important Safety Instructions WARNING: These apparatuses shall not be exposed to dripping or splashing and no objects filled with liquids, such as vases shall be placed on the apparatus. WARNING: To reduce the risk of electric shock, DO NOT expose units to rain or moisture.
  • Page 5 Lithium battery safety precautions To change battery please power off and take off the battery immediately. Keep the battery away from heat sources to prevent fire or explosion. Do not use a battery that is leaking, deformed, discolored or overheats. Take extra precautions to keep a leaking battery from fire.
  • Page 6: Table Of Contents

    1.4.1 Position away from lighting equipment ........................3 1.4.2 Avoid direct intense light .............................. 3 1.4.3 Example for planning the receiver ..........................3 Chapter 2 TES-5680 Series Classroom Audio System .............. 4 2.1 Overview ..................................4 2.2 Functions and indications ............................5 2.2.1 TES-5680M+TES-5680BX ............................
  • Page 7 3.5.1 TES-5600MAU series ..............................37 3.5.2 TES-5600MRN series ............................... 42 3.5.3 TES-5600BX series ..............................49 3.6 USB LINK .................................. 50 3.6.1 Installation of USB LINK ............................50 3.6.4 Remote PPT Click Function ............................50 3.6.5 Digital Laser Pointer ..............................50 3.6.2 Digital audio output ..............................
  • Page 8 6.1 Overview ..................................76 6.2 Functions and indicators ............................77 6.3 Installation .................................. 78 6.4 Operation ................................... 78 Chapter 7 Hanging microphone....................79 7.1 Overview ..................................79 7.2 Functions and indicators ............................80 7.2.1 TES-5675 series Hanging Microphone ........................80 7.2.2 TES-5675BX Hanging Microphone Control Pannel ....................
  • Page 9: Installation & User Guide

    About this manual: This manual is a comprehensive guide to the Chapter 7 Hanging Microphone installation and operation of TAIDEN Classroom Audio System. It includes the detailed description of the Detailed description of functions and operation of function and interface of the classroom audio system TES-5675 series hanging microphone.
  • Page 10 Installation & User Guide This manual is applicable to:  TES-5680 Series Classroom Audio System analog audio input/output, built-in audio power amplifier and integrated loudspeakers, RJ45 interface for extending TES-5680M/30 receiver) Interactive Audio Recording System Receiver (with built-in array microphone, high performance DSP with...
  • Page 11 Installation & User Guide TES-5600BX2/30 TES-5690MB Digital Infrared Classroom Audio System Control Box Digital Infrared Classroom Audio System Main Unit (with RJ45 interface, supports 2 wireless microphones, (supports 2 wireless microphones, with DSP, built-in built-in audio power amplifier can be connected to 4 audio power amplifier 2×200 W, network control) loudspeakers, can connect to TES-5600 series Wired TES-5690MC...
  • Page 12 Installation & User Guide TES-5600CSMN  Neck Lanyard Wired Desktop Microphone (standard stem microphone: 60cm, optional: 50/70cm; with a lockable charging station TES-5600NS_W Neck Lanyard (adjustable length) for one TES-5604 series microphone, can be unlocked TES-5600CLP Clip via central control system or via network management system;...
  • Page 13 Installation & User Guide  Cable Splitter  Speaker TES-0104C Wall Mounted Speaker (8 Ω, 40W) HPA-2240 Serial port Splitter (1 input & 4output (3 RS232+1 HCL-1090 RS485)) Line Array Column Loudspeaker (6 Ω, 60 W, black, TES-0104T/30 with adjustable installation brackets or fixed ones) 1×4 Cable Splitter (RJ45 interface, for extending HCL-1090B TES-5600RN/30)
  • Page 14: Chapter 1 System Introduction

    Chapter 1 System introduction 1.1 Overview 1.2 Functions and features In 2015, TAIDEN introduced its worldwide pioneering 1. World leading technology digital infrared technology into the field of multimedia Audio transmission and control based on proprietary teaching and released successively a series of classroom...
  • Page 15: System Technology

    1.3 System technology 1.3.1 IR radiation technology 1.3.2 Carriers and channels The core of the TAIDEN digital infrared classroom audio TAIDEN classroom audio system adopts 1-8 MHz wave system – dirATC (digital infrared Audio Transmitting and band. This wave band is suitable for the transmission of Control technologies) - is a new technology originated by wide band audio and corresponding signals.
  • Page 16: Position Planning Of The Digital Infrared Receiver

    1.4 Position planning of the digital infrared receiver 1.4.1 Position away from lighting equipment 1.4.3 Example for planning the receiver Although TAIDEN classroom audio system has good The reception angle of the digital infrared receiver is anti-interference performance to ambient light, the 150°...
  • Page 17: Chapter 2 Tes-5680 Series Classroom Audio System

    Chapter 2 TES-5680 Series Classroom Audio System 2.1 Overview TES-5680 series includes classroom audio system and TES-5685MB/30 digital infrared wireless classroom audio system. Digital Infrared Classroom Audio System Main Unit (with digital infrared receiver, supports 2 wireless microphones, analog audio input/output, built-in audio power amplifier...
  • Page 18: Functions And Indications

    2.2 Functions and indications 2.2.1 TES-5680M+TES-5680BX Side of TES-5680M/30 Top of TES-5608M/30 Rear panel of TES-5680BX Front panel of TES-5680BX Interactive audio recording system Figure 2.1 Figure 2.1: 1. RECEIVER interfaces (RJ45) 11. REC. volume knob  Connect to TES-5680BX for transmitting signals and 12.
  • Page 19: Tes-5685 System

    2.2.2 TES-5685 system Side of TES-5685MA/30 Button Side of TES-5685MB/MC TES-5685BX series TES-5685BXP series Figure 2.2 TES-5685 Series Classroom audio system Figure 2.2: Microphone indicator (only TES-5685MA)  Display the status of array microphone (on or AUDIO I/O interface (RJ45) ...
  • Page 20 13. Switch IR frequency Auto. Fade/ Broadcast mode AFC function Auto. Fade/ AUTO FADE Remote mode 14. Line in volume knob 15. Speaker volume knob 16. IR indicator 17. USB interface  For firmware upgrade  Connect to PC for remote PPT click function 18.
  • Page 21: Installation

    2.3 Installation 2.3.1 Ceiling mounted of TES-5680M 2.3.1.1 Ceiling mounted 1 Figure 2.3 Ceiling mounted 1 Mounting steps: Step 1: Install the ceiling mounting kit at the top of the TES-5680M; Step 2: Drill a hole with 98 mm diameter into the ceiling (for mounting and heat elimination during operation); WARNING: ...
  • Page 22 2.3.1.2 Ceiling mounted 2 Figure 2.4 Ceiling mounted 2 Mounting steps: Step 1: Position the mounting bracket on the ceiling according to the installation location of the TES-5680M and mark the positions of the drilling holes. Drill two holes (5 mm diameter, 30 mm depth) into the ceiling. Step 2: Put the included rubber plugs into the mounting holes on the ceiling;...
  • Page 23: Suspensing Mounted Of Tes-5680M

    2.3.2 Suspensing mounted of TES-5680M Figure 2.5 Suspensing mounted Mounting steps: Step 1: Position the mounting bracket on the ceiling according to the installation location of the TES-5680M and mark the positions of the drilling holes. Drill two holes (5 mm diameter, 30 mm depth) into the ceiling. Step 2: Put the included rubber plugs into the mounting holes on the ceiling;...
  • Page 24: Ceiling Mounted Of Tes-5685M

    2.3.3 Ceiling mounted of TES-5685M Figure 2.6 Ceiling mounted of TES-5685M Mounting steps: Step 1: Use the Ceiling Bracket as a template, mark 2 hole locations on the diagonal. Fix the ceiling bracket in the ceiling with M6 wedge concrete anchors; Step 2: Align the slot on the top of TES-5685M to the snap-fit joint and push TES-5685M in the direction of the arrow until the tapped spacer and the screw hole are aligned;...
  • Page 25: Suspension Mounted Of Tes-5685M

    2.3.4 Suspension mounted of TES-5685M Figure 2.7 Suspension mounted of TES-5685M Mounting steps: Step 1: Use the suspension tube as a template to mark 2 hole locations on the diagonal. Insert M6 wedge concrete anchor into the concrete surface; Step 2: Loop the safety wire around the M6 wedge concrete anchors. Route the opposite end of the safety wire through the hole on the suspension tube;...
  • Page 26: Connection

    2.4 Connection 2.4.1 Interactive audio recording system interface (TES-5600MIC or TES-5600CSM series), Interactive audio recording system integrates digital infrared technology, DSP technology with array connect to device like amplifier for output balance microphone which can realize the “3A” algorithm (ANC, audio via LINE BAL, connect to recording device via AEC, AGC) and support detect the sound direction for REC.,...
  • Page 27: Tes-5685Ma Interactive Audio Recording System

    2.4.2 TES-5685MA interactive audio recording system TES-5685MA Interactive Audio Recording System interface (RJ45), connect to extern audio device via PC IN (PC) or USB interface ( TES-5600MIC or integrates speakers, control main unit, digital infrared receiver and amplifier, built-in DSP technology with TES-5600CSM series)...
  • Page 28: Tes-5685Mb/Mc Digital Infrared Classroom Audio System

    2.4.3 TES-5685MB/MC digital infrared classroom audio system TES-5685MB/MC Digital Infrared Classroom Audio interface (RJ45), connect to extern audio device via PC IN (PC) or USB interface ( TES-5600MIC or integrates speakers, control main unit, digital System infrared receiver and amplifier, supports 1 or 2 digital TES-5600CSM series), connect to recording device IR microphones.
  • Page 29: Operation

    2.5 Operation All operation of TAIDEN Classroom Audio System will be introduced one by one in this section. 2.5.1 TES-5680M+TES-5680BX 1. Speaker volume 6. Function switcher Adjust the speaker via the “VOL.” knob on the Setting the function parameters via the dip switcher TES-5680BX control box.
  • Page 30  Network Setting  Setting the IP address, netmask and gateway, reboot the device after setting. Click the DHCP can get the address automatically.  Apply: apply the setting  Set Default: click the button to default the device; user can also continuously flip the AFC DIP switch on the TES-5680BX control box twice within 5 seconds to default the device.
  • Page 31 9. USB link Interactive audio recording system has a built-in USB LINK (2 channels, 16bit, 48kHz) which can be connected to the computer through USB cable (software requirement: Win7 or higher) for digital audio input/output. Cooperating with the TES-560x microphone can realize remote control PPT slide. In the following we take Win7 system as an example to introduce the function and operation of the USB LINK.
  • Page 32 Figure 2.13 Adjusting microphone volume Note:  High volume may lead to distortion, user can confirm a suitable volume by recording and playback when necessary;  When recording, the audio quality may be affected if using unsuitable sampling rate or resolution so it is suggested to select 48 kHz or its multiple for the sampling rate and 16 bit for the resolution;...
  • Page 33 Note:  Please select the TES-5680 USB LINK as the current device on playback. Usually, TES-5680 USB LINK will be activated after connecting to the computer, instead of the default audio device. If there is an error in playback, please select the TES-5680 USB LINK manually in case there is a mistake in audio device selection.
  • Page 34: Tes-5685M+Tes-5685Bx

    TES-5685MA combo unit connects to PC via LAN interface, input the IP address of Classroom Audio 4. Function switcher System (see the IP address via “TAIDEN Device Setting the function parameters via the switcher (switch Discovery” software) into web browser to search the...
  • Page 35  Noise Suppression Level: adjust the noise reduce range (0 to 3 level) of the array microphone, the smaller the value, the more the noise but the farer the working distance, vice versa.  Auto Dodge (effective when the AUTO FADE switcher on the TES-5680BX is on): ...
  • Page 36: Chapter 3 Tes-5600 Series Classroom Audio System

    Chapter 3 TES-5600 Series Classroom Audio System 3.1 Overview TAIDEN TES-5600 series based on digital infrared TES-5600MRN technology provides an ideal audio solution for Digital Infrared Classroom Audio System Main Unit teaching environment thanks to its capabilities of (with RJ45 interface, built-in webserver, can be setup...
  • Page 37: Functions And Indications

    3.2 Functions and indications TES-5600RN/30 series TES-5600RN/30 series Front panel of TES-5600BX/30 series Rear panel of TES-5600BX/30 series Front panel of TES-5600MAU/30 Rear panel of TES-5600MAU/30 Front panel of TES-5600MRN Rear panel of TES-5600MRN Front panel of TES-5600MHN Rear panel of TES-5600MHN Figure 3.1 TES-5600 series classroom audio system...
  • Page 38 31. ETHERNET (RJ45) 19. Menu display  For connection to PC, with built-in webserver  128×36 OLED, displays main unit status and  Universal match TAIDEN Smart Classroom System configuration menu. Management Platform 20. Knob  For connection to central control system, supports ...
  • Page 39: Installation

    3.3 Installation 3.3.1 TES-5600RN series ceiling mounted 1 ① PA3x18 screw ② Fixing bracket ③ Rubber plug ④ Hard ceiling (such as concrete ceiling) ⑤ TES-5600RN series digital infrared receiver Figure 3.2 TES-5600RN digital infrared receiver ceiling mounted 1 Mounting steps: Step 1: Position the fixing bracket on the ceiling according to the installation location of the TES-5600RN and mark the positions of the drilling holes.
  • Page 40: Tes-5600Rn Series Ceiling Mounted 2

    3.3.2 TES-5600RN series ceiling mounted 2 ① PM4x20 screw ② Fixing bracket ③ Nut ④ Ceiling ⑤ TES-5600RN series digital infrared receiver TES-5600RN Figure 3.3 digital infrared receiver ceiling mounted 2 Mounting steps: Step 1: Position the fixing bracket on the ceiling according to the installation location of the TES-5600RN and mark the positions of the drilling holes.
  • Page 41: Tes-5600Rn Series Tripod-Mounted

    3.3.3 TES-5600RN series tripod-mounted ① Tripod-mounted stator ② M3 screw ③ Nut ④ Fixing bracket ⑤ TES-5600RZJ (with flexible tube) ⑥ TES-5600ZJ2 Figure 3.4 TES-5600RN digital infrared receiver tripod mounted Mounting steps: Step 1: Fix the fixing bracket onto the TES-5600RZJ with M3 screws; Step 2: Fix the tripod-mounted stator onto the other end of the TES-5600RZJ with M3 screws;...
  • Page 42: Tes-5600Rn Series Wall-Mounted (Adjustable Angle)

    3.3.4 TES-5600RN series wall-mounted (Adjustable angle) ① Tripod-mounted stator ② M3 screw ③ Nut ④ Fixing bracket ⑤ TES-5600RZJ (with flexible tube) ⑥ Wall TES-5600RN Figure 3.5 digital infrared receiver tripod mounted Mounting steps: Step 1: Fix the fixing bracket onto the TES-5600RZJ with M3 screws; Step 2: Put the slots of TES-5600R digital infrared receiver into the fixing bracket and fix it with clockwise rotation;...
  • Page 43: Connection

    Features include power controlling, system PA volume external device (such as recorder) via LINE OUT, and controlling and controlling of various electric devices, speakers connection via SPEAKER OUTPUT. such as DVD, recorder, etc. RS-232C interface is Also, TAIDEN TES-5600MAU/30 digital infrared wireless available. classroom audio system...
  • Page 44: Tes-5600Mrn Series

    3.4.2 TES-5600MRN Series 3.4.2.1. Connecting to Digital IR RECEIVER select the corresponding "Audio Scene" through operation menu (3.5.2.10). TES-5600MRN / TES-5600MHN main unit connects to TES-5600RN/30 series via IR RECEIVER interfaces, it supports 1 or 2 digital infrared wireless microphone. Figure 3.9 Connecting to wired/hanging microphone Figure 3.7 Connecting to TES-5600RN/30 3.4.2.4.
  • Page 45 TES-5600MRN / TES-5600MHN main unit, and both via the TSW-5600MN Parameter Setting Tool or built-in the central control system and charging station can be webserver. It can also be universal adapt to TAIDEN coupled to one system which can realize unlock TES-5600SW...
  • Page 46 System connection: Figure 3.8 System connection for TES-5600MRN (Scene:IR+MIC2(T)+M3) Figure 3.9 System connection for TES-5600MHN (Scene:IR+MIC2(S)+M3)
  • Page 47 Audio scenes: The TES-5600MRN/TES-5600MHN main unit supports 5 audio scenarios: IR+M2(T)+M3, IR+M2(T)+M1(T), IR+M2(T)+M1(S), IR+M2(S)+M1(S) and IR+M2(S)+M3. You need to select "Audio Scene" in the setting menus on front panel (see details in section 3.5.2.10 Audio Scene) according to actual system connection. Scene 1 IR+M2(T)+M3:...
  • Page 48 Scene 4 IR+M2(S)+M1(S): When the system adopts 1~2 TES-560x digital infrared wireless microphone, both MIC1 and MIC2 interfaces connect with TES-5675S hanging microphones. Please setup Audio Scene as "IR+M2(S)+M1(S)" in the operation menus on front panel. The relationship between audio input and output is as the below table: Audio input Line in TES-560x...
  • Page 49: Tes-5600Bx Series

    3.4.3 TES-5600BX series The TES-5600BX/30 series control box features built-in or TES-5600MIC wired microphone can connect to the amplifier, microphone control and volume adjustment. A type USB interface for audio transmission, audio TES-5600BX/30 series connects to TES-5600RN/30 output to external device (such as amplifier) via LINE series via RECEIVER interfaces, and external audio BAL, and speakers connection via SPEAKER.
  • Page 50: Configuration And Operation

    3.5 Configuration and operation 3.5.1 TES-5600MAU series TES-5600MAU series Digital infrared wireless system main unit can be configured and set up through menu operation with knob. All menu items operation will be introduced one by one in this section.  Rotate the knob to switch submenus one by one;...
  • Page 51 3.5.1.2 Line In Vol. Adjust the volume of Line In, range: -∞ (mute), -30 dB to 0 dB. 3. Rotate the knob to adjust the EQ, range: -10 dB to +10 dB; 4. Press the knob to confirm. 1. Press the knob to enter the line in selection interface; 3.5.1.5 Auto Fade Select the trigger signal sources of LINE IN fade.
  • Page 52 3.5.1.7 Line In 1 Set. 3.5.1.9 Mic Low Cut Set the low cut of microphone. 1. Press the knob to enter the setting interface; 1. Press the knob to enter the setting interface; 2. Rotate the knob to select a type between Line In, Mic In and USB Mic, if select “Line In”...
  • Page 53 3.5.1.12 Child Lock 3.5.1.15 About Set the child lock function. Display the version of the device. 1. Press the knob to enter the setting interface; In this interface, user also can see the information of the microphone in use, see and change the receivable frequencies of the main unit.
  • Page 54 Note:  Please receivable frequencies changing function restrainedly for keeping normal use;  Factory reset invalid receivable frequencies changing. Protection  IR receiver protection: activated when the IR receiver short circuit or other unusual circumstance happens, the OLED displays “IR Receiver Abnormal!” ...
  • Page 55: Tes-5600Mrn Series

    3.5.2 TES-5600MRN series TES-5600MRN Digital infrared wireless system main unit can be configured and set up through menu operation with knob. All menu items operation will be introduced one by one in this section. A) Starting initialization Switch on and press the "POWER" button, the TES-5600MRN digital infrared wireless system main unit will start initialization: ...
  • Page 56 1. Press the knob to enter the setting interface; 3.5.2.2 Line In Vol. Adjust the volume of Line In, range: -∞ (mute), -30 dB to 0 dB. 2. Rotate the knob to select a fade way among Off, Low Voice, High Voice and IR Signal. ...
  • Page 57 3.5.2.6 Line Out 2 Set. 3. Rotate the knob to adjust the volume and then press the knob to confirm. 1. Press the knob to enter the setting interface; 2. Rotate the knob to select function for interface Line 3.5.2.9 IR Ctrl. Vol. out2 between "Line Out"...
  • Page 58 or IR+M2(S)+M3 according to actual system connection, and then press the knob to confirm. 2. Rotate the knob to select and then press the knob to Digital Infrared Wireless Microphone TES-5675 series hanging microphone confirm. connected to MIC1 interface TES-5675 series hanging microphone connected to MIC2 interface TES-5600CSM series wired microphone connected to Type A USB interface...
  • Page 59 1. Press the knob to enter the setting interface; 1. Press the knob to enter the maximum gain selection interface; 2. Rotate the knob to select cursor speed, the adjustable range is -2 ~ +2. Then press the knob to confirm. 2.
  • Page 60 PC. Enter the IP address of the main unit in the address bar of the browser, and enter the password (default "TAIDEN-5600") in the login interface to access the built-in webserver. The built-in webserver has multiple functions, such as 3.5.2.21 About...
  • Page 61 Manually set the host IP address, subnet mask and gateway, and also support DHCP to automatically obtain network settings.  Check "Set Server Parameter" to set the IP address and service port number of the TAIDEN TES-5600SW Digital Wireless Classroom Audio Management Platform.  Apply: apply settings;...
  • Page 62: Tes-5600Bx Series

    3.5.3 TES-5600BX series 3.5.3.1. Speaker volume 3.5.3.5. Function switcher Adjust the volume of speakers and LINE OUT via the Setting the function parameters via the switcher (switch “VOL.” knob on the TES-5600BX/30 control box, range up is 1, switch down is 0) -30 dB to 0 dB.
  • Page 63: Usb Link

    3.6 USB LINK 3.6.5 Digital Laser Pointer TES-5600MAU series TES-5600MRN series When TES-5600MAU series / TES-5600MRN series / TES-5600BX series main unit can use as a HD keyboard TES-5600BX series main unit is connected to a PC via B-type / device and can support remote PPT function and digital C-type USB interface, and the TSW-5608B digital laser pointer laser...
  • Page 64: Digital Audio Input

    current device on recording or communication. Note:  Please select the TES-5600M USB LINK as the Usually, TES-5600M USB LINK will be automatically activated after connecting to the computer, instead of current device on playback. Usually, TES-5600M the default audio device. If there is error in recording, USB LINK will be activated after connecting to the please select the sound card manually in case there computer, instead of the default audio device.
  • Page 65: Chapter 4 Tes-5690 Series Classroom Audio System

    Chapter 4 TES-5690 Series Classroom Audio System 4.1 Overview TAIDEN TES-5690 series digital infrared classroom audio system integrated main unit and professional digital audio power amplifier, which can connect to speakers, support 2 IR microphone for interaction of teacher and students. It with central control interface for realizing centralized control.
  • Page 66: Functions And Indications

    4.2 Functions and indications Front panel of TES-5690M TES-5690MA Rear panel of TES-5690MB Rear panel of Rear panel of TES-5690MC Figure 4.1 TES-5690 series classroom audio system Figure 4.1: 1. Power button 5. B type USB interface  For firmware upgrade 2.
  • Page 67 8. Phantom power indicator 9. MIC1/LINE1 IN and volume konb  3P phoenix interface, for analog balanced audio input, with phantom power 10. Priority IN and volume konb  3P phoenix interface, for stereo analog audio input 11. CTL trigger interface ...
  • Page 68: Connection

    4.3 Connection The TES-5690M series Digital Infrared Classroom trigger is enabled, the audio of priority will be routed to Audio System Main Unit connects to TES-5600RN/30 all the outputs with all other inputs muted. series Digital Infrared Receiver which features built-in TES-5690M main unit is also equipped with a B type amplifier, microphone control and volume adjustment.
  • Page 69: Configuration And Operation

    4.4 Configuration and operation TES-5690M series Digital infrared wireless system main 4.4.1 IR Mic Sens. unit can be configured and set up through menu operation Adjust the sensitivity of the digital infrared wireless with knob. All menu items operation will be introduced microphones.
  • Page 70: Mute By Ir Mic

    4.4.4 Mute by IR Mic 4.4.8 Network If select “On”, the wired microphone will be mute when Set the IP address, subnet mask, gateway of the system.  the digital IR wireless microphone is on. IP address Rotate the knob to select On or Off, then press the knob 1.
  • Page 71: Fb Suppress

    4.4.10 FB Suppress 4.4.12 About Set a FB (feedback) suppress level. Display the version of the device. Rotate the knob to select a level among Off, High and Low, then press the knob to confirm after adjusting. 4.4.13 Return Note: Press the knob to return to the Initial interface.
  • Page 72: Usb Link

    4.5 USB LINK TES-5690 series main unit built-in USB Audio (2 channels, 16bit, 48 kHz) which can be connected to the computer through USB cable (software requirement: Win7 or higher) for digital audio input/output. The main unit cooperating with the TES-560x microphone can realize remote PPT click function In the following we take Win7 system as an example to introduce the function and operation of the USB LINK.
  • Page 73: Digital Audio Input

    4.5.4 Digital audio input The TES-5690M main unit can be connected to the computer for digital audio input. Please adjust and test the TES-5690M USB LINK to a suitable volume when using for the first time. Adjust method: open the control panel-sound (or right click the volume icon on the taskbar and select sound), and select the speakers (TES-5690M USB LINK) and modify its setting in the Playback dialog box, as shown in the following figure: 4.5.5 Digital audio output...
  • Page 74 Figure 4.6: Adjusting playback volume Note:  Please select the TES-5690M USB LINK as the current device on playback. Usually, TES-5690M USB LINK will be activated after connecting to the computer, instead of the default audio device. If there is an error in playback, please select the TES-5690M USB LINK manually in case there is a mistake in audio device selection.
  • Page 75: Webserver

    Web server interface. As shown below: Figure 4.8 Login Select the interface language and password (default password is TAIDEN-5690), then click 'login' button to enter the main interface. Figure 4.9 Main interface (Main Unit Info.) On the left side of the webserver, it shows navigation menu, including 5 menu items: Main Unit Info., Main Unit State,...
  • Page 76 (1) Main Unit Info. Main unit Info. is the default main interface, and click navigation menu on the left side can also enter the interface as below: Figure 4.9 Main Unit Info.  Main Unit Info. : show information of the main unit, including machine type, hardware version, software version, web version, Mac address and manufacture date ...
  • Page 77  Phantom Power: set the phantom power supply function of MIC1/LINE1 interface;  Infrared Mic Mute External Mic: if it is enable, the microphone or USB microphone will be mute when the infrared microphone is turned on;  Infrared Mic Low cut: turn on / off the low cut function of the infrared microphone; ...
  • Page 78 Figure 4.12 Add Scene Delete: Choose a record from the scene list and click ' – Delete' button , the record will be deleted immediately; Rename: Choose a record from the scene list and click ' Remane' button, then edit the name for the scene; Parameter save: Choose a record from the scene list and click ' Save' button, all audio parameter will be store in the scene, and can be recalled any time.
  • Page 79  Limiter: click to enter the pressure limiter settings of SPEAKER OUT. Figure 4.15 Limiter of SPEAKER OUT Click “ " to adjust the pressure limit, the Threshold, Attack Time and Decay Time can be set.  Delay: click to enter the delay settings of SPEAKER OUT, range :0 to 30 ms. Figure 4.16 Delay of SPEAKER OUT ...
  • Page 80: Chapter 5 Digital Infrared Wireless Microphone

    Chapter 5 Digital infrared wireless microphone 5.1 Overview TES-560x series digital infrared wireless microphone is ergonomically compact and of elegant design, can be held in hand hung around the neck via a nice strap or fit into the shirt pocket. Functions can be realized: speak, frequency selection, remote volume control, etc.
  • Page 81: Functions And Indicators

    5.2 Functions and indicators Front of TES-5604N_W Top and button of TES-5604N Front of TES-5608AN Back of TES-5608AN Top and bottom of Top and bottom of TES-5608BN/20 TES5608CN/20 Front of TES-5608BN/20, TES-5608CN/20 Figure 5.1 Digital infrared wireless microphone...
  • Page 82 Figure 5.1: 1. Microphone 16. “F” button  Switch between PPT mode and MIC mode; 2. MIC indicator  Adjusting parameters with other button 3. L/M indicator  For adjusting the parameters 17. Laser pointer button  Press and hold on it to open the laser pointer, and Microphone on/off button release to close it (TES-5608CN/20 only);...
  • Page 83: Infrared Light Coverage

    5.3 Infrared light coverage Infrared light is directional invisible light. Infrared wireless microphone gets best sensitivity when it directly faces a receiver. The infrared transmitter on TES-560x series digital infrared wireless microphone is designed to be at its best position to guarantee maximum emission angle and to ensure the most effective infrared signal transmission. The vertical transmission angle is 90°, and the horizontal transmission angle for TES-5604N_W and TES-5608AN is 120°, while for TES-5602A_G is 360°.
  • Page 84: Operation

    5.4 Operation 2. External audio input External audio devices (such as CD player) can be 5.4.1 TES-5602A_G (handheld type) connected via theφ3.5 mm AUDIO IN interface and the microphone will be muted automatically; TES-5602A_G handheld type digital infrared wireless microphone combines speaking, mute, and working mode 3.
  • Page 85: Tes-5604N_W

    5.4.2 TES-5604N_W Volume control Mic. On/Off and frequency channel selection Press the “…” to select volume control function, the  Keep pressing the microphone on/off button about 2 MIC indication will turn on; seconds to power on and turn on the microphone, the Adjust the volume by the “+/-”...
  • Page 86 Audio input Fitting the microphone External audio devices (such as MP3) or microphone can Put the hanging piece of the TES-5600NS series neck be connected via the Ø3.5 mm AUDIO IN interface and lanyard into the slot, adjust the length of the neck lanyard the microphone will be muted automatically.
  • Page 87: Tes-5608Bn/20,Tes-5608Cn/20

    5.4.3 TES-5608BN/20,TES-5608CN/20 Volume control Mic. On/Off and frequency channel selection Adjust the volume by the “+/-” buttons. The volume will be  Keep pressing the microphone on/off button about 2 increased/decreased (MIC indicator flashes) until it seconds to power on and turn on the microphone, the reaches the maximum/minimum.
  • Page 88  This function should be used with a main unit that supports the digital laser pointer function.  For switching the mode of the digital laser pointer, it needs to run the TAIDEN Presentation software; otherwise you can only use the default "mouse cursor" mode. For more details, see "TAIDEN Presentation...
  • Page 89: Chapter 6 Wired Microphone

    Chapter 6 Wired microphone 6.1 Overview Types: TES-5600MIC Wired Desktop Microphone (standard stem microphone: 60cm, optional: 50/70cm) TES-5600CSM Wired Desktop Microphone (standard stem microphone: 60 cm, optional: 50/70 cm; with a charging station for two TES-5604/5608N series microphones, with TES- ADP5V power adapter) TES-5600CSML Wired Desktop Microphone (standard stem microphone:...
  • Page 90: Functions And Indicators

    6.2 Functions and indicators Front of TES-5600MIC Front of TES-5600CSM series Bottom Side Figure 6.1 Wired microphone Figure 6.1: 1. Dismountable microphone socket 2. Microphone on/off button 3. Touch key  For unlocking wireless microphone 4. Charging station  TES-5600CSML/CSMN with a lockable charging station for one TES-5604 /5608N series microphone ...
  • Page 91: Installation

    Digital Infrared Wireless Presenter, user can use the “TES-5600” APP to scan QR code for unlocking microphone. Note:  Please scan the QR code on www.taiden-edu.com to install the “TES-5600” APP. 5. Network control TES-5600CSMN series weird microphone connects to...
  • Page 92: Chapter 7 Hanging Microphone

    Chapter 7 Hanging microphone 7.1 Overview Types: TES-5675T Hanging Microphone (Gray, round, 14mm Cardioid unidirectional microphone used to pick up the audio of the teachers' lecture) TES-5675S Hanging Microphone (Gray, round, omnidirectional microphone, used to pick up students' interactive audio) TES-5675H Hanging Microphone...
  • Page 93: Functions And Indicators

    7.2 Functions and indicators 7.2.1 TES-5675 series Hanging Microphone Front of TES-5675T/S Side of TES-5675T/S Rear of TES-5675T/S Side of TES-5675H Front / Rear of TES-5675H Front / Rear of TES-5675HS Side of TES-5675HS Figure 7.1 Hanging microphone Figure 7.1: Microphone identification Connect terminal (require phantom power 48 V) ...
  • Page 94: Tes-5675Bx Hanging Microphone Control Pannel

    interface of TES-5600MRN / TES-5600MHN main unit  TES-5675HS microphone has a audio cable with a 3-PIN Phoenix connector, the red, white and black wires are corresponding to Signal + / Signal- and Ground. Work indicator  The indicator light is green under normal status, is off when not connected to main unit 7.2.2 TES-5675BX Hanging Microphone Control Box Side of TES-5675BX...
  • Page 95: Installation

    7.3 Installation 7.3.1 TES-5675T / TES-5675S Figure 7.1 Hanging mounting for TES-5675T / TES-5675S Mounting steps: Step 1: Drill 4 holes (Ø 5 mm, 30 mm depth); Step 2: Thread the wire from the hole to the trunking and wipe it in the bar; Step 3: Fix MA-120P retractable hanging bar;...
  • Page 96: Tes-5675H

    7.3.2 TES-5675H Figure 7.2 Hanging mounting for TES-5675H Mounting steps: Step 1: Drill 4 holes (Ø 5 mm, 30 mm depth); Step 2: Thread the wire from the hole to the trunking and wipe it in the bar; Step 3: Fix MA-120P retractable hanging bar; Step 4: Fix TES-5675H;...
  • Page 97: Tes-5675Hs

    7.3.2 TES-5675HS Figure 7.3 Hanging mounting for TES-5675HS Mounting steps: Step 1: Drill 4 holes (Ø 5 mm, 30 mm depth); Step 2: Thread the wire from the hole to the trunking and wipe it in the bar; Step 3: Fix MA-120P retractable hanging bar; Step 4: Fix TES-5675HS;...
  • Page 98: Chapter 8 Accessories

    Chapter 8 Accessories 8.1 Power Adapter  TES-ADP5V power adapter  TES-ADP24V power adapter Used for charging TES-560x series digital infrared Used to power for TES-5600MAU/ TES-5680BX/ wireless microphone TES-5604CS series, 8Ω/40W TES-5600BX/ TES-5630MA connecting with 2 × TES-5604CHG/01 charging station. speakers Figure 8.4 TES-ADP5V power adapter ...
  • Page 99: Dedicated Cable

    8.2 Dedicated Cable  RG-59 Coaxial-cable  CBLRJ45 Ethernet Extension Cable CBL-SPK speaker cable is used for connection between CBLRJ45 Ethernet Extension Cable is used to connect the TES-5600R and the digital IR wireless system between TES-5600RN/30 receiver control box/combo unit. TES-56xxM classroom audio...
  • Page 100 TES-5600CSN Figure 8.12 charging station Note:  Please scan the QR code on www.taiden-edu.com Figure 8.15 TES-5604CHG/09 charging station to install the “TES-5600” APP. 5600CSN charging station can be fixed to the desktop through the positioning hole at the bottom. The...
  • Page 101: Microphone

    8.4 Microphone 8.5 TES-5600ZJ2  TES-1021 clip microphone Used for TES-5604/07 series microphones. ■ Ø 3.5 mm stereo plug with a 0.3-meter cable ■ Weight: 10 g Figure 8.16 TES-1021  TES-1022 single-ear microphone Used for TES-5604/07 series microphones. ■ Ø...
  • Page 102: Ma-120P Retractable Hanging Bar

    8.7 MA-120P retractable hanging bar Used mounting TES-5675 series hanging microphone ■ Length: 0.6 meter, can be adjusted up to 1.2 meter ■ Weight: 320 g Figure 8.23 TES-5600M Cabinet Installation Accessories (single unit)  TES-5600M Cabinet Installation Accessories (two units) Used for installing two TES-5600M Series Digital Infrared Wireless System Main Unit to cabinet.
  • Page 103: Cable Splitter

     TES-5600CLP Used for TES-560x series microphones, ■ Direction adjustable ■ Weight: 6 g. Figure 8.29 1 ×2 BNC cable splitter  SB-408C3 (third-party fitting) Figure 8.27 TES-5600CLP Used for extending TES-5600R ■ One input and four output interfaces ■ 5 F interfaces, used with RG-6/U cable 8.11 Cable Splitter ■...
  • Page 104: Speaker

    8.13 Speaker  HPA-2240(A/B) wall-mounted speaker  HSC-106E 6.5-inch Ceiling Loudspeaker Components: 1×6.5" woofer unit + 1×0.75" tweeter Ceiling-mount Wall-mounted, equipped with U bracket; ABS panel + metal box Power consumption: 8 Ω, 40 W; Coaxial structure 6 Ω, 40 W (HPA-2240B); Frequency Range: 90 Hz –...
  • Page 105  HCL-1090B line array column loudspeaker Coverage pattern: Horizontal: 150°, vertical: 30°; Max. SPL: 120 dB (speech mode) 117 dB (music mode); Power consumption: 200 W (800 W peak), 2 hrs 120 W (480 W peak), 100 hrs; Impedance: 6 Ω; Frequency response: 80 Hz~18 kHz (-10 dB);...
  • Page 106   HCL-404E 4 Units Two-way Column Loudspeaker HCL-404EJ 4 Units Two-way Column Loudspeaker Components: 4×4" complex carbon fiber diaphragm Components: 4×4" complex carbon fiber diaphragm midwoofer units + 12×0.75" nano carbon midwoofer units + 12×0.75" nano carbon fiber diaphragm tweeters fiber diaphragm tweeters Enclosure Material: Birch + black polyurea finish Enclosure Material: Birch + black polyurea finish...
  • Page 107: Chapter 9 Technical Data

    Chapter 9 Technical data 9.1 System specification System performance System environmental conditions Conforms to IEC 60914, the international standard for Working conditions fixed/stationary/transportable conference systems Temperature range: - Transport: -40 °C to +70 °C - Operating: 0 °C to +45 °C Transmission characteristics Max.
  • Page 108: Tes-5680 Classroom Audio System

    9.2 TES-5680 classroom audio system Type TES-5680M/30 TES-5680BX/30 Power supply by DC 24 V 2.7 A Power TES-5680BX/30 (TES-ADP24V adapter) Cable CBLRJ45 Ethernet Extension Cable Line in Nominal value: +2 dBu; maximum value: +11 dBu 22 kΩ Line in impedance Line out Nominal value: +2 dBu;...
  • Page 109: Tes-5685 Series Classroom Audio System

    9.3 TES-5685 series classroom audio system Type TES-5685MA/30 TES-5685MB/30 TES-5685MC/30 TES-5685BX/30 Power 100-240V 50/60 Hz Power supply by TES-5685M Cable CBLRJ45 Ethernet Extension Cable Line in Nominal value: +2 dBu; maximum value: +10 dBu 22 kΩ Line in impedance Line out Nominal value: +11 dBu;...
  • Page 110: Tes-5600 Series Digital Infrared Wireless Classroom Audio System

    9.4 TES-5600 series digital infrared wireless classroom audio system Type TES-5600RN series TES-5600MAU/30 TES-5600BX/30 Supplied from TES-5600BX series Power 24V DC, 2.7 A (TES-ADP24V) /TES-5600MAU series CBLRJ45 Ethernet Extension Cable Cable Nominal value: +2 Nominal value: +6 Line in dBu; maximum value: dBu;...
  • Page 111 Type TES-5600MRN / TES-5600MHN Power 24V DC, 2.7 A (TES-ADP24V) Cable CBLRJ45 Ethernet Extension Cable (for connection to TES-5600RN/30 series) Line in Nominal value: +2 dBu; maximum value: +12 dBu Line out Nominal value: +4 dBu; maximum value: +14 dBu; 100 Ω...
  • Page 112: Tes-5690 Classroom Audio System

    9.5 TES-5690 classroom audio system Type TES-5690MA TES-5690MB TES-5690MC Power AC 100-240 V, 3.0-1.5A AC 100-240 V, 2.3-1.2A Line in Nominal value: +6 dBu; maximum value: +12 dBu Single-ended input :10 kΩ; differential input :20 kΩ Line in impedance Line out Nominal value: -20 dBu;...
  • Page 113: Digital Infrared Wireless Microphone

    9.6 Digital infrared wireless microphone Type TES-5602A_G TES-5604N_W TES-5608/20 √ Remote volume control Power USB supply (5 V 2A) ≤290 mA ≤320 mA Current consumption Wavelength 870 nm (AM: Brightness modulation) Modulation DQPSK method Carrier frequency Audio channel 1/2/3/4/5:1.00 /1.67/ 2.33/ 3.00/ 3.67 MHz Vertical: 0°~ 90°, Horizontal: 120°...
  • Page 114: Hanging Microphone

    9.7 Hanging microphone TES-5675HS Type TES-5675S TES-5675T TES-5675H Power Phantom power 11 ~ 52 V,2mA Dimensions (mm) 47 g Weight 140 g 140 g 140 g Black Color Gray Gray Black Omnidirectional Microphone type 14 mm Cardioid unidirectional microphone microphone Sensitivity -32 dBV/Pa -30 dBV/Pa...
  • Page 115: Power Adapter

    9.8 Power adapter TES-ADP24V Type TES-ADP24VA TES-ADP5V6A TES-ADP5V TES-ADP19V AC 100-240 V, 50 /60 Hz Mains voltage 24 V DC, 2.7 A 24 V DC, 3.75 A Output 5 V DC, 6.0 A 5 V DC, 2.0 A 19 V DC, 3.42 A Cable Length 2.8 m 1.0 m...
  • Page 116: Connection Details

    Type TES-5600CSL TES-5600CSN Voltage 5 V DC, 2.0 A (TES-ADP5V) Dimensions (mm) Weight 0.3 kg Color White Type TES-5604CHG/09 TES-5604CHG/01 TES-5604CHG/02 Voltage 5 V DC, 6.0 A (TES-ADP5V6A) 5 V DC, 2.0 A (TES-ADP5V) Dimensions (mm) Weight 0.8 kg 0.1 kg 0.2 kg Color White...
  • Page 117: Appendix

    Appendix...