Page 1
Classroom Audio System Installation and Operating Manual V 1.4...
Page 2
To protect your hearing, please avoid high pressure level on earphones. Adjust to a lower and convenient level. If any detailed information needed, please contact your local retailer or TAIDEN service center in your region. Any feedback, advice and suggestion about the products are appreciated.
Page 3
TAIDEN Service Center. The apparatus should be connected to the MAINS 20. All TAIDEN products are guaranteed for definite time socket-outlet with protective earth. (see the WARRANTY CARD for details) excluding the Clean only with dry cloth.
Page 4
Important Safety Instructions WARNING: These apparatuses shall not be exposed to dripping or splashing and no objects filled with liquids, such as vases shall be placed on the apparatus. WARNING: To reduce the risk of electric shock, DO NOT expose units to rain or moisture.
Page 5
Lithium battery safety precautions To change battery please power off and take off the battery immediately. Keep the battery away from heat sources to prevent fire or explosion. Do not use a battery that is leaking, deformed, discolored or overheats. Take extra precautions to keep a leaking battery from fire.
1.4.1 Position away from lighting equipment ........................3 1.4.2 Avoid direct intense light .............................. 3 1.4.3 Example for planning the receiver ..........................3 Chapter 2 TES-5680 Series Classroom Audio System .............. 4 2.1 Overview ..................................4 2.2 Functions and indications ............................5 2.2.1 TES-5680M+TES-5680BX ............................
Page 7
3.5.1 Mic Sens................................... 40 3.5.2 Line In Vol................................. 41 3.5.3 EQ Setting ................................. 41 3.5.4 Auto Fade .................................. 41 3.5.5 FB Suppress ................................41 3.5.6 Line In 1 Set................................42 3.5.7 Remote Ctrl................................42 3.5.8 Mic Low Cut ................................42 3.5.9 Music/Voice ................................
Installation & User Guide About this manual: This manual is a comprehensive guide to the installation and operation of TAIDEN Classroom Audio System. It includes the detailed description of the function and interface of the classroom audio system components, system connection and installation, system set-up and operation.
Page 10
Installation & User Guide This manual is applicable to: TES-5680 Series Classroom Audio System TES-5685MCP/30 TES-5680M/30 Digital Infrared Classroom Audio System Main Unit (with Interactive Audio Recording System Receiver (with digital infrared receiver, supports 1 wireless microphone, built-in array microphone, high performance DSP with...
Page 11
Installation & User Guide TES-5600BX2/30 TES-5606 Digital Infrared Classroom Audio System Control Box Digital Infrared Wireless Microphone (white, built-in (with RJ45 interface, supports 2 wireless microphones, rechargeable lithium battery, excl. adapter, used with built-in audio power amplifier can be connected to 4 TES-5600NS_W neck lanyard or TES-5600CLP clip) loudspeakers, can connect to TES-5600 series Wired TES-5607...
Page 12
Installation & User Guide TES-5600CSN CBLRJ45-10 Charging Station (with a lockable charging station for 10 m Ethernet Extension Cable (with drain wire and one TES-5604 series microphone, can be unlocked via shielded RJ45 plug) central control system or via network management CBLRJ45-20 system;...
Chapter 1 System introduction 1.1 Overview 1.2 Functions and features In 2015, TAIDEN introduced its worldwide pioneering 1. World leading technology digital infrared technology into the field of multimedia Audio transmission and control based on proprietary teaching and released successively a series of classroom...
1.3 System technology 1.3.1 IR radiation technology 1.3.2 Carriers and channels The core of the TAIDEN digital infrared classroom audio TAIDEN classroom audio system adopts 2-6 MHz wave system – dirATC (digital infrared Audio Transmitting and band. This wave band is suitable for the transmission of Control technologies) - is a new technology originated by wide band audio and corresponding signals.
1.4 Position planning of the digital infrared receiver 1.4.1 Position away from lighting equipment 1.4.3 Example for planning the receiver Although TAIDEN classroom audio system has good The reception angle of the digital infrared receiver is anti-interference performance to ambient light, the 150°in vertical and 360°in horizontal.
Chapter 2 TES-5680 Series Classroom Audio System 2.1 Overview TES-5680 series includes classroom audio system and digital infrared wireless classroom audio system. TES-5685MB/30 Digital Infrared Classroom Audio System Main Unit (with digital infrared receiver, supports 2 wireless microphones, Types: analog audio input/output, built-in audio power amplifier...
2.2 Functions and indications 2.2.1 TES-5680M+TES-5680BX Side of TES-5680M/30 Top of TES-5608M/30 Rear panel of TES-5680BX Front panel of TES-5680BX Interactive audio recording system Figure 2.1 Figure 2.1: 1. RECEIVER interfaces (RJ45) 11. REC. volume knob Connect to TES-5680BX for transmitting signals and 12.
2.2.2 TES-5685 system Button of TES-5685M Side of TES-5685MA series Side of TES-5685MB/MC/30 Side of TES-5685MCP/30 TES-5685BX series TES-5685BXP/30 Rear panel of TES-5685PA/30 Front panel of TES-5685PA/30 Figure 2.2 TES-5685 Series Classroom audio system Figure 2.2: Microphone indicator (only TES-5685MA) 4 Speakers (A/B/C/D) ...
Page 19
For firmware upgrade ETHERNET (RJ45) For connection to Ethernet to see the system status 32. Reset button Press it 3 times continuously to restore the factory and adjust the system parameters For upgrade settings REC. interface (Ø 3.5mm) and volume knob 33.
2.3 Installation 2.3.1 Ceiling mounted of TES-5680M 2.3.1.1 Ceiling mounted 1 Figure 2.3 Ceiling mounted 1 Mounting steps: Step 1: Install the ceiling mounting kit at the top of the TES-5680M; Step 2: Drill a hole with 98 mm diameter into the ceiling (for mounting and heat elimination during operation); WARNING: ...
Page 21
2.3.1.2 Ceiling mounted 2 Figure 2.4 Ceiling mounted 2 Mounting steps: Step 1: Position the mounting bracket on the ceiling according to the installation location of the TES-5680M and mark the positions of the drilling holes. Drill two holes (5 mm diameter, 30 mm depth) into the ceiling. Step 2: Put the included rubber plugs into the mounting holes on the ceiling;...
2.3.2 Suspension mounted of TES-5680M Figure 2.5 Suspension mounted Mounting steps: Step 1: Position the mounting bracket on the ceiling according to the installation location of the TES-5680M and mark the positions of the drilling holes. Drill two holes (5 mm diameter, 30 mm depth) into the ceiling. Step 2: Put the included rubber plugs into the mounting holes on the ceiling;...
2.3.3 Ceiling mounted of TES-5685M Figure 2.6 Ceiling mounted of TES-5685M Mounting steps: Step 1: Use the Ceiling Bracket as a template, mark 2 hole locations on the diagonal. Fix the ceiling bracket in the ceiling with M6 wedge concrete anchors; Step 2: Align the slot on the top of TES-5685M to the snap-fit joint and push TES-5685M in the direction of the arrow until the tapped spacer and the screw hole are aligned;...
2.3.4 Suspension mounted of TES-5685M Figure 2.7 Suspension mounted of TES-5685M Mounting steps: Step 1: Use the suspension tube as a template to mark 2 hole locations on the diagonal. Insert M6 wedge concrete anchor into the concrete surface; Step 2: Loop the safety wire around the M6 wedge concrete anchors. Route the opposite end of the safety wire through the hole on the suspension tube;...
2.4 Connection 2.4.1 Interactive audio recording system interface (TES-5600MIC or TES-5600CSM series), Interactive audio recording system integrates digital infrared technology, DSP technology with array connect to device like amplifier for output balance microphone which can realize the “3A” algorithm (ANC, audio via LINE BAL, connect to recording device via AEC, AGC) and support detect the sound direction for REC.,...
2.4.2 TES-5685MA interactive audio recording system TES-5685MA Interactive Audio Recording System interface (RJ45), connect to extern audio device via PC IN (PC) or USB interface ( TES-5600MIC or integrates speakers, control main unit, digital infrared receiver and amplifier, built-in DSP technology with TES-5600CSM series)...
2.4.3 TES-5685MB/MC digital infrared classroom audio system TES-5685MB/MC Digital Infrared Classroom Audio interface (RJ45), connect to extern audio device via PC IN (PC) or USB interface ( TES-5600MIC or integrates speakers, control main unit, digital System infrared receiver and amplifier, supports 1 or 2 digital TES-5600CSM series), connect to recording device IR microphones.
Page 28
system Figure 2.11 TES-5685MCP digital infrared classroom audio...
2.5 Operation All operation of TAIDEN Classroom Audio System will be introduced one by one in this section. 2.5.1 TES-5680M+TES-5680BX 1. Speaker volume 6. Function switcher Adjust the speaker via the “VOL.” knob on the Setting the function parameters via the dip switcher TES-5680BX control box.
Page 30
Network Setting Setting the IP address, netmask and gateway, reboot the device after setting. Click the DHCP can get the address automatically. Apply: apply the setting Set Default: default the device, user can also switch the AFC on the TES-5680BX control box four times in 5 seconds to default the device.
Page 31
9. USB link Interactive audio recording system has a built-in USB LINK (2 channels, 16bit, 48kHz) which can be connected to the computer through USB cable (software requirement: Win7 or higher) for digital audio input/output. Cooperating with the TES-560x microphone can realize remote control PPT slide. In the following we take Win7 system as an example to introduce the function and operation of the USB LINK.
Page 32
Figure 2.14 Adjusting microphone volume Note: High volume may lead to distortion, user can confirm a suitable volume by recording and playback when necessary; When recording, the audio quality may be affected if using unsuitable sampling rate or resolution so it is suggested to select 48 kHz or its multiple for the sampling rate and 16 bit for the resolution;...
Page 33
Note: Please select the TES-5680 USB LINK as the current device on playback. Usually, TES-5680 USB LINK will be activated after connecting to the computer, instead of the default audio device. If there is an error in playback, please select the TES-5680 USB LINK manually in case there is a mistake in audio device selection.
TES-5685MA combo unit connects to PC via LAN interface, input the IP address of Classroom Audio 4. Function switcher System (see the IP address via “TAIDEN Device Setting the function parameters via the switcher (switch Discovery” software) into web browser to search the...
2.5.3 TES-5685MCP+TES-5685PA Noise Suppression Level: adjust the noise 1. Speaker volume reduce range (0 to 3 level) of the array TES-5685MCP combo unit integrates four speakers microphone, the smaller the value, the more the (A/B/C/D) which be divided into 2 groups (A+B and C+D), noise but the farer the working distance, vice adjust the two groups of speakers via the “VOL.”...
Page 36
Apply: apply the setting. Set Default: default the device. b. TES-5685PA TES-5685PA control box connects to PC via LAN interface. Use the “TAIDEN Device Discovery” software to search the IP address of TES-5685PA, as shown below: How to enter Web server: ...
Page 37
Four icons at the top-right of Web interface are ”Audio Setting( )”, "Device Management ( )", "Regional Group Management ( )" and “Device Parameters( )”. (1) Audio Setting The interface includes the audio parameters of PA in, Line in, PA out, Monitor out; and the setting of audio input/output at the right side.
Page 38
Figure 2.18 PEQ setting GEQ: 31 segment graphical equalization, drag pushers to adjust equilibrium parameter. It is only for output channel. You can also enable/disable low-cut and high-cut features, and set their frequency point. Figure 2.19 GEQ setting DRC: DRC (dynamic ratio compressor) interface is shown as below. It is only for output channel. Threshold, Ratio, Attack Time and Decay Time can be set.
Page 39
Figure 2.20 DRC setting Audio input/output setting LINE IN: green background display when enable. It cannot be selected when the PA trigger is enabled. Monitor out: select the channel of monitor out. PA out setting: mode of PA out, includes: Single Device, Grouping, All Devices and Stop Broadcasting. ...
Page 40
Figure 2.21 Device management Click of a device to enter its Web server interface; Click of a device to see its basic setting, the device name and optional group can be adjusted, and then click the “Return” button to save and return to device management interface.
Page 41
The “Regedit” in the upper right corner of the interface can enter the search and add device page: the interface shows the existing and the new discovery devices, click “+” on existing devices bar to add a new device, click “×” on the upper right corner of a device to delete the device.
Page 42
Click on the bottom of a group to enter the group management settings interface: regional group name can be changed; added devices can be displayed and click “×” to delete it; click “+” on the button of a device in No Added Deveices bar to add it to current group. Click the “Return” button to return to the previous page. (4) Device Parameters Setting the parameters of TES-5685PA.
Chapter 3 TES-5600 Series Classroom Audio System 3.1 Overview TAIDEN TES-5600 series based on digital infrared technology provides an ideal audio solution for teaching environment thanks to its capabilities of anti-interference, privacy assurance, easy-manageability and audio clarity, etc. The system consists of one digital infrared wireless control box, digital infrared receivers, and digital infrared wireless microphones.
3.2 Functions and indications TES-5600RN/30 series TES-5600RN/30 series Front panel of TES-5600BX/30 series Rear panel of TES-5600BX/30 series Front panel of TES-5600MAU/30 Rear panel of TES-5600MAU/30 Figure 3.1 TES-5600 series classroom audio system Figure 3.1: 1. Fixing bracket 8. PC IN (Ø 3.5 mm) and volume konb 2.
Page 45
17. Speaker interface 18. Power supply interface 19. Menu display 128×36 OLED, displays main unit status and configuration menu. 20. Knob For menu operation; For master volume control. 21. B type USB interface For firmware upgrade ...
3.3 Installation 3.3.1 TES-5600RN series ceiling mounted 1 ① M3 screw ② Fixing bracket ③ Rubber plug ④ Hard ceiling (such as concrete ceiling) ⑤ TES-5600RN series digital infrared receiver TES-5600RN Figure 3.2 digital infrared receiver ceiling mounted 1 Mounting steps: Step 1: Position the fixing bracket on the ceiling according to the installation location of the TES-5600RN and mark the positions of the drilling holes.
3.3.2 TES-5600RN series ceiling mounted 2 ① M3 screw ② Fixing bracket ③ Nut ④ Ceiling ⑤ TES-5600RN series digital infrared receiver TES-5600RN Figure 3.3 digital infrared receiver ceiling mounted 2 Mounting steps: Step 1: Position the fixing bracket on the ceiling according to the installation location of the TES-5600RN and mark the positions of the drilling holes.
3.3.3 TES-5600RN series tripod mounted ① Tripod-mounted stator ② M3 screw ③ Nut ④ Fixing bracket ⑤ TES-5600RZJ (with flexible tube) ⑥ TES-5600ZJ2 Figure 3.4 TES-5600RN digital infrared receiver tripod mounted Mounting steps: Step 1: Fix the fixing bracket onto the TES-5600RZJ with M3 screws; Step 2: Fix the tripod-mounted stator onto the other end of the TES-5600RZJ with M3 screws;...
3.3.4 TES-5600RN series wall mounted (Adjustable angle) ① Tripod-mounted stator ② M3 screw ③ Nut ④ Fixing bracket ⑤ TES-5600RZJ (with flexible tube) ⑥ Wall TES-5600RN Figure 3.5 digital infrared receiver tripod mounted Mounting steps: Step 1: Fix the fixing bracket onto the TES-5600RZJ with M3 screws; Step 2: Put the slots of TES-5600R digital infrared receiver into the fixing bracket and fix it with clockwise rotation;...
3.4 Connection 3.4.1 TES-5600BX series The TES-5600BX/30 series control box features built-in or TES-5600MIC wired microphone can connect to the amplifier, microphone control and volume adjustment. A type USB interface for audio transmission, audio TES-5600BX/30 series connects to TES-5600RN/30 output to external device (such as amplifier) via LINE series via RECEIVER interfaces, and external audio BAL, and speakers connection via SPEAKER.
Features include power controlling, system PA volume external device (such as recorder) via LINE OUT, and controlling and controlling of various electric devices, speakers connection via SPEAKER OUTPUT. such as DVD, recorder, etc. RS-232C interface is Also, TAIDEN TES-5600MAU/30 digital infrared wireless available. classroom audio system...
3.5 Configuration and operation of TES-5600MAU/30 TES-5600MAU/30 Digital infrared wireless system main unit can be configured and set up through menu operation with knob. All menu items operation will be introduced one by one in this section. A) Starting initialization Switch on and press the "POWER"...
3.5.2 Line In Vol. 3.5.4 Auto Fade Adjust the volume of Line In, range: -∞ (mute), -30 dB to Select the trigger signal sources of LINE IN fade. LINE 0 dB. IN volume will be reduced 18 dB after triggering. 1.
3.5.6 Line In 1 Set. 3.5.8 Mic Low Cut Set the low cut of microphone. 1. Press the knob to enter the setting interface; 1. Press the knob to enter the setting interface; 2. Rotate the knob to select a type between Line In, Mic In and USB Mic, if select “Line In”...
In the “About” interface, power on a microphone or an icon “ ” will display and the menu interface is locked. The prompt interface as below: press the “MUTE” button on the microphone, its version and frequency will be displayed. ...
Page 56
D) Protection IR receiver protection: activated when the IR receiver short circuit or other unusual circumstance happens, the OLED displays “IR Receiver Abnormal!” Alarm function: activated when a high level being input to the phoenix interface or the controllable microphone or central control system send an alarm signal to the main unit, the OLED displays “Alarm On!”.
3.6 USB LINK TES-5600MAU/30 series main unit and TES-5600BX series control box have a built-in USB Audio (2 channels, 16bit, 44.1kHz) which can be connected to the computer through USB cable (software requirement: Win7 or higher) for digital audio input/output. The main unit cooperating with the TES-560x microphone can realize remote PPT-page switch control.
3.6.2 Digital audio output When the TES-5600MAU/30 main unit is connected to computer with USB cable, lossless sound can be recorded during class on computer. Using the recording software or the third party communication software, such as recorder, Skype and so on, functions like recording, remote instruction, remote communication can be implemented.
Figurer 3.11: Adjusting playback volume Note: Please select the TES-5600M USB LINK as the current device on playback. Usually, TES-5600M USB LINK will be activated after connecting to the computer, instead of the default audio device. If there is an error in playback, please select the TES-5600M USB LINK manually in case there is a mistake in audio device selection.
3.7 Operation of TES-5600BX series 1. Speaker volume 6. PPT Slide Adjust the volume of speakers and LINE OUT via the TES-5600BX/30 control box connects to PC via a Micro “VOL.” knob on the TES-5600BX/30 control box, range USB interface, cooperates with the TES-560x series -30 dB to 0 dB.
Chapter 4 TES-5690 Series Classroom Audio System 4.1 Overview TAIDEN TES-5690 series digital infrared classroom audio system integrated main unit and professional digital audio power amplifier, which can connect to speakers, support 2 IR microphone for interaction of teacher and students. It with central control interface for realizing centralized control.
4.2 Functions and indications Front panel of TES-5690M TES-5690MA Rear panel of TES-5690MB Rear panel of Rear panel of TES-5690MC Figure 4.1 TES-5690 series classroom audio system Figure 4.1: 1. Power button 5. B type USB interface For firmware upgrade 2.
Page 63
8. MIC1/LINE1 IN and volume konb 3P phoenix interface, for analog balanced audio input, with phantom power 9. Priority IN and volume konb 3P phoenix interface, for stereo analog audio input 10. CTL trigger interface System output the audio of priority interface when it is short circuiting.
4.3 Connection The TES-5690M series Digital Infrared Classroom trigger is enabled, the audio of priority will be routed to Audio System Main Unit connects to TES-5600RN/30 all the outputs with all other inputs muted. series Digital Infrared Receiver which features built-in TES-5690M main unit is also equipped with a B type amplifier, microphone control and volume adjustment.
4.4 Configuration and operation TES-5690M series Digital infrared wireless system main 4.4.1 IR Mic Sens. unit can be configured and set up through menu operation Adjust the sensitivity of the digital infrared wireless with knob. All menu items operation will be introduced microphones.
4.4.4 Mute by IR Mic 4.4.8 Network If select “On”, the wired microphone will be mute when Set the IP address, subnet mask, gateway of the system. the digital IR wireless microphone is on. IP address Rotate the knob to select On or Off, then press the knob 1.
4.4.10 FB Suppress 4.4.12 About Set a FB (feedback) suppress level. Display the version of the device. Rotate the knob to select a level among Off, High and Low, then press the knob to confirm after adjusting. 4.4.13 Return Note: ...
4.5.2 Digital audio output When the TES-5690M main unit is connected to computer with USB cable, lossless sound can be recorded during class on computer. Using the recording software or the third party communication software, such as recorder, Skype and so on, functions like recording, remote instruction, remote communication can be implemented.
Figurer 4.6: Adjusting playback volume Note: Please select the TES-5690M USB LINK as the current device on playback. Usually, TES-5690M USB LINK will be activated after connecting to the computer, instead of the default audio device. If there is an error in playback, please select the TES-5690M USB LINK manually in case there is a mistake in audio device selection.
4.6 Webserver ETHERNET interface of TES-5690 connected to PC through switch, input the device address in the browser Web address bar to open the Web server interface. As shown below: Figurer 4.8 Login Select the interface language and click login to enter the main interface. TES-5690M Web server include Main Unit State, Audio Settings, System Info.
Page 72
infrared microphone is turned on; Infrared Mic Low cut: turn on / off the low cut function of the infrared microphone; Current Carrier Setting: displays the current frequency; Infrared Mic FB Suppression: with OFF/ LOW / HIGH three steps. The higher the FB suppress level, the better the FB suppress effect.
Page 73
Adjustable the input gain (range: mute, 0 to 60 dB). Click “ " to adjust the PEQ (parameter equalization). The channel frequency response curve displays on the interface. There are five filters available, the type (parameter filter, low shelf, elevated), quality factor (Q), frequency point (F0) and amplification low cut (Boost) of each filter can be set.
Page 74
Output: Set the output volume, including LINE OUT and SPEAKER OUT. Click the icon on the left horn of an channel to mute it, click a output channel to enter its volume adjustment interface, drag the push to adjust the volume, range :0 to -30 dB.
Chapter 5 Digital infrared wireless microphone 5.1 Overview TES-560x series digital infrared wireless microphone is ergonomically compact and of elegant design, can be held in hand hung around the neck via a nice strap or fit into the shirt pocket. Functions can be realized: speak, frequency selection, remote volume control, etc.
5.2 Functions and indicators Top and button of TES-5604C Front of TES-5604C Side of TES-5604C Front of TES-5604N Top and button of TES-5604N Front of TES-5605 Side of TES-5605 Front and bottom of TES-5606 Side of TES-5606 Front of TES-5607 Rear of TES-5607 Figure 5.1 Digital infrared wireless microphone...
Page 77
Figure 5.1: 1. Microphone 16. “F” button Switch between PPT mode and MIC mode; 2. MIC indicator Adjusting parameters with other button 3. L/M indicator For adjusting the parameters Note: 4. Microphone on/off button TES-5607 with touch button which is on the top Note: of the blind spot.
5.3 Infrared light coverage 5.4 Operation Infrared light is directional invisible light. Infrared wireless The TES-560x series digital infrared wireless microphone microphone gets best sensitivity when it directly faces a combines functions including speaking, working mode receiver. The infrared transmitter on TES-560x series setting, volume control and PowerPoint slide control.
Page 79
all signal indicators shall flicker in turn twice; 3.0 MHz Switch the mode by pressing the “…”/”F” button. The 3.67 MHz signal indicators indicates the current working mode : TES-5606 Auto. shut Frequency down mode 1.0 MHz TES-5604 Series 1.67 MHz 2.33 MHz 3.0 MHz TES-5605/06...
Page 80
Keep pressing the “…” button to adjust audio input mode, Charging status PWR indicator L/M indicator indicates the current working mode: Charging Green (blink) Input mode Full Green (on) MIC IN Error Yellow (blink) LINE IN TES-5607 TES-5605/06 TES-5607 microphone without battery, it can be power TES-5605/06 microphone comes with an audio cable supplied by connecting to TES-5607PB power bank via...
6.2 Functions and indicators Front of TES-5600MIC Front of TES-5600CSM series Bottom Side Figure 6.1 Wired microphone Figure 6.1: 1. Dismountable microphone socket 2. Microphone on/off button 3. Touch key For unlocking wireless microphone 4. Charging station TES-5600CSML/CSMN with a lockable charging station for one TES-5604 series microphone ...
TES-5604 series microphone, user can use the “TES-5600” APP to scan QR code for unlocking microphone. Note: Please scan the QR code on www.taiden-edu.com to install the “TES-5600” APP. 4. Network control TES-5600CSMN series weird microphone connects to...
Chapter 7 Accessories 7.1 Power Adapter TES-ADP19V power adapter TES-ADP24V power adapter Used for the classroom audio system with 4 speakers. Connect the TES-ADP24V to the power adapter interface at the rear panel of theTES-5680/5600BX control box. Figure 7.4 TES-ADP19V power adapter Figure 7.1 TES-ADP24V power adapter 7.2 Power Bank ...
CLB-SPK speaker cable CBL-SPK speaker cable is used for the HCL-1200 line array column loudspeaker. ■ Length of per roll:305 meter ■ Weight of per roll: 14.1 kg ■ Color: pearl white Power bank bag Figure 7.6 Note: Please make sure that the battery is fully charged at least every three months.
Powered by TES-ADP5V adapter Dimensions: 58×97×58 mm Color: white Weight: 0.3 kg Figure 7.16 TES-5604CHG/09 charging station TES-5600CSN Figure 7.13 charging station Note: Please scan the QR code on www.taiden-edu.com to install the “TES-5600” APP.
7.5 Microphone 7.6 TES-5600ZJ2 TES-1021 clip microphone Used for TES-5604/07 series microphones. ■ Ø 3.5 mm stereo plug with a 0.3- meter cable ■ Weight: 10 g Figure 7.17 TES-1021 TES-1022 single-ear microphone Used for TES-5604/07 series microphones. ■...
7.8 TES-5685P Series Suspension 7.10 Cable Splitter Used for TES-5685M series classroom audio system. TES-0104T/30 Length: 0.5/1.0/1.5 m. Used for extending TES-5600RN/30 series receiver, with 1 input and 4 output RJ45 interfaces. Weight: 68 g Figure 7.25 TES-0104T/30 1 ×2 BNC cable splitter Figure 7.22 TES-5685P suspension Used for extending TES-5600R series receiver, with 1...
Chapter 8 Technical data 8.1 System specification System performance System environmental conditions Conforms to IEC 60914, the international standard for Working conditions fixed/stationary/transportable conference systems Temperature range: - Transport: -40 °C to +70 °C - Operating: 0 °C to +45 °C Transmission characteristics Max.
8.2 TES-5680 classroom audio system Type TES-5680M TES-5680BX/30 DC 24 V 2.7 A Power Power supply by TES-5680BX (TES-ADP24V adapter) Cable CBLRJ45 Ethernet Extension Cable Line in Nominal value: +2 dBu; maximum value: +11 dBu 22 kΩ Line in impedance Line out Nominal value: +2 dBu;...
8.3 TES-5685 series classroom audio system Type TES-5685MA/30 TES-5685MB/30 TES-5685MC/30 TES-5685BX series Power 100-240V 50/60 Hz Power supply by TES-5685M Cable CBLRJ45 Ethernet Extension Cable Line in Nominal value: +2 dBu; maximum value: +10 dBu 22 kΩ Line in impedance Line out Nominal value: +11 dBu;...
Page 94
Type TES-5685MCP/30 TES-5685PA/30 Power 100-240V 50/60 Hz DC 24V, 1.5 A Cable CBLRJ45 Ethernet Extension Cable Nominal value: +2 dBu; PC/PA in Max. +20 dBu maximum value: +10 dBu 22 kΩ Line in impedance Nominal value: +11 dBu; Line out maximum value: +17 dBu 100 Ω...
8.4 TES-5600 series digital infrared wireless classroom audio system Type TES-5600RN series TES-5600MAU/30 TES-5600BX/30 Supplied from Power 24V DC, 2.7 A (TES-ADP24V) TES-5600BX/TES-5600MAU CBLRJ45 Ethernet Extension Cable Current consumption Nominal value: +2 Nominal value: +6 Line in dBu; maximum dBu; maximum value: +12 dBu value: +12 dBu Nominal value: +8...
8.5 TES-5680 classroom audio system Type TES-5690MA TES-5690MB TES-5690MC Power AC 100-240 V, 3.0-1.5A AC 100-240 V, 3.0-1.5A Line in Nominal value: +6 dBu; maximum value: +12 dBu Single-ended input :10 kΩ; differential input :20 kΩ Line in impedance Line out Nominal value: -20 dBu;...
8.7 Power adapter Type TES-ADP24V TES-ADP5V6A TES-ADP5V TES-ADP19V Mains voltage AC 100-240 V, 50 /60 Hz Output 24 V DC, 2.7 A 5 V DC, 6.0 A 5 V DC, 2.0 A 19 V DC, 3.42 A Cable Length 2.8 m 1.0 m 1.5 m Dimensions (mm)
Type TES-5600CSL TES-5600CSN Voltage 5 V DC, 2.0 A (TES-ADP5V) Dimensions (mm) Weight 0.3 kg Color White Type TES-5604CHG/09 TES-5604CHG/01 TES-5604CHG/02 Voltage 5 V DC, 6.0 A (TES-ADP5V6A) 5 V DC, 2.0 A (TES-ADP5V) Dimensions (mm) Weight 0.8 kg 0.1 kg 0.2 kg Color White...