Taiden HCS-4100MA/50 Installation And Operating Manual

Taiden HCS-4100MA/50 Installation And Operating Manual

Fully digital congress system hcs-4100/50 series
Table of Contents

Advertisement

HCS-4100/50 Series Fully Digital Congress System
Fully Digital Congress System
Installation and Operating Manual
V 1.8

Advertisement

Table of Contents
loading

Summary of Contents for Taiden HCS-4100MA/50

  • Page 1 HCS-4100/50 Series Fully Digital Congress System Fully Digital Congress System Installation and Operating Manual V 1.8...
  • Page 2  To protect your hearing, avoid high pressure level on earphones. Adjust to a lower and convenient level. If any detailed information is needed, please contact your local agent or TAIDEN service center in your region.  Any feedback, advice and suggestion about the products is appreciated TAIDEN is the registered trademark of TAIDEN Co., Ltd.
  • Page 3: Important Safety Instructions

    19. For service, please contact the nearest TAIDEN The MAINS plug serving as a disconnection device, Service Center. 20. All TAIDEN products are guaranteed for definite time should be easy to operate. The apparatus should be connected to the MAINS...
  • Page 4 Important Safety Instructions The exclamation mark within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance (servicing) instructions in the literature accompanying the appliance. WARNING: To reduce the risk of fire or electric shock, DO NOT expose units to rain or moisture.
  • Page 5: Table Of Contents

    Contents Installation & User Guide ......................VIII Chapter 1: Introduction ....................... 1 1.1 Summary ................................1 1.2 System technology ............................2 1.3 Functions ................................6 1.4 Features ................................8 Chapter 2: Congress main unit (CMU) ..................10 2.1 Fully Digital Congress System Main Unit ......................11 2.1.1 Functions and instructions ............................
  • Page 6 3.7 HCS-4360/61/62/63 series congress unit ..................... 116 3.7.1 Functions and indications ............................116 3.7.2 Installation ................................119 3.7.3 Connection ................................120 3.7.4 Operation ................................122 3.8 HCS-4338N/50 series congress unit ......................126 3.8.1 Functions and indications ............................126 3.8.2 Connection ................................128 3.8.3 Operation ................................
  • Page 7 Chapter 4: Interpreter unit ...................... 214 4.1 HCS-4385U/50 .............................. 215 4.1.1 Functions and indications ............................215 4.1.2 Installation ................................218 4.1.3 Connection ................................219 4.1.4 Setup ..................................221 4.1.5 Operation ................................226 4.2 HCS-8385/60 ..............................228 4.2.1 Functions and indications ............................228 4.2.2 Installation ................................
  • Page 8 8.3 Congress unit ..............................269 8.3.1 HCS-48U6 series congress unit ..........................269 8.3.2 HCS-48U7/U8/U9 series congress unit ........................271 8.3.3 HCS-48U10 series congress unit ..........................273 8.3.4 HCS-4886/87/88 series congress unit ........................274 8.3.5 HCS-4380/82/70/71 series congress unit ........................ 275 8.3.6 HCS-4360/61/62/63 series congress unit ........................
  • Page 9: Installation & User Guide

    Installation & User Guide About this manual This manual is a comprehensive guide to the Chapter 6:Peripheral equipment and accessories TAIDEN installation and operation of the HCS-4100/50 An introduction to the HCS-4100/50 peripheral Fully Digital Congress System. It includes the detailed...
  • Page 10 Flush-mounting Loudspeaker Panel (HCS-48U6SELM  Congress main units HCS-48U6MICM needed, black) HCS-4100MA/50 Fully Digital Congress System Main Unit (discussion, voting, 64 HCS-48U7 series congress units: CHs, multi-mode optical fiber interface) HCS-48U7CMIC HCS-4100MA/FS/50 Fully Digital Congress System Chairman Unit (flush-mounting, Fully Digital Congress System Main Unit (discussion, voting, 64...
  • Page 11 Installation & User Guide HCS-4340DUN/52 HCS-48U10 series congress units: Multi-function Connector (for HCS-48U7 series, for connection to HCS-48U10CVS 1 delegate unit + 1 loudspeaker, can be connected with E-ink Fully Digital Congress System Chairman Unit (flush-mounting, 3 electronic nameplate, black) voting keys, contactless IC-Card reader, 64 CHs, OLED, black) HCS-48U10CVSN HCS-48U8 series congress units:...
  • Page 12 Installation & User Guide HCS-4888DE/50 HCS-4338N series congress units: HCS-4888DE/52 HCS-4338NCVS/50 Fully Digital Congress System Delegate Unit (tabletop, 5 voting Fully Digital Congress System Chairman Unit (tabletop, 3 voting keys) keys, 64 CHs, OLED) HCS-4886NX_S/50 HCS-4338NDVS/50 HCS-4886NX_G/52 Fully Digital Congress System Delegate Unit (tabletop, 3 voting Fully Digital Congress System Operator Unit (tabletop, 256x32 keys, 64 CHs, OLED) HCS-4338NDV/50...
  • Page 13 Installation & User Guide HCS-4866CS/50 HCS-4860/2M series congress units: Fully Digital Congress System Chairman Unit (tabletop, 64 CHs, HCS-4860CS/50/2M OLED) Fully Digital Congress System Chairman Unit (tabletop, 64 CHs, HCS-4866DS/50 OLED, rectangular columnar metal microphone, main Fully Digital Congress System Delegate Unit (tabletop, 64 CHs, microphone + backup microphone, silver microphone + black OLED) base)
  • Page 14 Installation & User Guide HCS-4841ND/50 HCS-4325/26/27 series congress units: Fully Digital Congress System Delegate Unit (flush-mounting, HCS-4325U/50 HCS-4340/50 needed) Dual 64-Channel Selector (flush-mounting, black) HCS-4841CU/50 HCS-4325(N)/50 Fully Digital Congress System Chairman Unit (flush-mounting, Dual 64-Channel Selector (flush-mounting) HCS-4340/50 needed) HCS-4325(N)W/50 HCS-4841DU/50 Dual 64-Channel Selector (flush-mounting, contactless IC-Card Fully Digital Congress System Delegate Unit (flush-mounting,...
  • Page 15 Installation & User Guide HCS-4368DFW/50 HCS-4340HDAF/50P Fully Digital Voting System Delegate Unit (tabletop, 5 voting keys, Multi-function Connector (for connection to 1 condenser 256x32 LCD, waterproof, antistatic 12000 V, contactless IC-Card microphone + 1 5-key voting unit + 1 channel selector, +48 V reader) phantom power, charcoal gray) HCS-4368CF/FM/50...
  • Page 16: Chapter 1: Introduction

    30 Hz to 20 kHz frequency digital technologies, audio technologies and network response. techniques. Furthermore, with perfect integration of HCS-4100/50 Fully Digital Congress System consists TAIDEN Conference Sign-in System and Central congress main unit, contribution units Control System, HCS-4100/50 system takes the application software.
  • Page 17: System Technology

    CPU as the kernel of the chip of discussion unit and interpreter advanced technology infrastructure. unit TDN: Dedicated digital communication chip for TAIDEN digital congress system networking DAC: Digital-to-analog conversion chip RISC: Central processing chipset of congress main...
  • Page 18 Figure 1.1.4 MCA-STREAM data stream format  Modular system structure  Duplicate and backup connection via “Closed Loop - Daisy Chain” connection Any kind of configuration can be set up just by daisy-chaining HCS-4100/50 fully digital congress units. For important meetings, especially those which The modular system structure of HCS-4100/50 is consider connection reliability as their leading point, applicable to any kind of congress and provides an...
  • Page 19 compatible wireless LAN techniques (802.11) - such as HCS-8300 and HCS-4100/50 series congress units, PDAs - which can be used to control a conference convenient for wiring and installation. system wirelessly. The import of network topology also All congress units of HCS-8300 and HCS-4100/50 makes the conference system merge with intelligent series (except HCS-8338 and HCS-8348 series) are building networks.
  • Page 20  Installation and transportation Easy installation another vital feature HCS-4100/50 Series Fully Digital Congress System. All HCS-4100/50 series digital congress units equipped with a 1.5-meter - 6P-DIN cable (with a male connector) and a 0.6-meter - 6P-DIN cable (with a female connector) except HCS-4330/50 series which has a 2.1-meter - 6P-DIN cable (with a male connector) and a socket on the housing.
  • Page 21: Functions

    (YES/NO/ABSTAIN) can be implemented even to talk without a PC. The result is displayed on the LCD  VIP unit configurable: of every contribution unit.  By using TAIDEN conference management  Cooperating with corresponding software system software, a maximum of 32 delegate...
  • Page 22 System LCD show: The seamless integration of HCS-4100/50 Series Fully  Active microphone amount, request amount, Digital Congress System with the TAIDEN Conference delegates’ signed-in and voting results, etc. Sign-in System and the Central Control System  Messages provides comprehensive congress system solutions.
  • Page 23: Features

    1.4 Features  System reliability With a PC and TAIDEN conference management system software, more functions can be achieved, System reliability, as described below, has always been including enhanced microphone control, simultaneous the guiding principle while designing HCS-4100/50 interpretation, delegate...
  • Page 24  System maintenance TAIDEN application software provides testing functions for online testing the operating conditions such as validity of the keys, LCD and microphones. A detailed test report is issued for quick and simple...
  • Page 25: Chapter 2: Congress Main Unit (Cmu)

    378 interpreter units, 4096 discussion/voting units and an infinite number of channel selectors. Product types: HCS-4100MA/50 Fully Digital Congress System Main Unit (discussion, voting, 64 CHs, multi-mode optical fiber interface) HCS-4100MA/FS/50 Fully Digital Congress System Main Unit (discussion, voting, 64...
  • Page 26: Fully Digital Congress System Main Unit

    2.1 Fully Digital Congress System Main Unit 2.1.1 Functions and instructions 2.1.1.1 Front panel Figure 2.1.1 Front panel of HCS-4100M/50 CMU Figure 2.1.1  Electric level adjustment knob 1. Power light a. Switches to red in standby mode; b. Switches to blue when operating. 8.
  • Page 27 Figure 2.1.2 Rear panel of HCS-4100M/50 CMU Figure 2.1.2 14. Fiber interface 17. Contribution units ring connection LED  HCS-4100MA/50: multi-mode optical fiber, SC  When output works properly (≥ 1 contribution unit connector; connected), LED will flash;  HCS-4100MA/FS/50: single-mode optical fiber, ...
  • Page 28: Installation

    27. RS-232C port x 2  “COM” port is used for connecting to a central control system for central controlling, as well as for system diagnosis;  “TEST” port is used for updating and monitoring. 2.1.2 Installation The CMU can be fixed in a standard 19-inch cabinet. The CMU is equipped with a pair of fixing brackets ①.
  • Page 29: Connection

    2.1.3 Connection 2.1.3.1 To congress units HCS-4100/50 series CMU has 2 outlet (6P-DIN) trunk-line cable sockets for connecting to congress units. HCS-4100/50 series congress units are equipped with a cable with a standard 6P-DIN male connector. When connecting the CMU to the congress units, just connect the male connector of the first unit to the socket of the CMU.
  • Page 30 3-cord XLR balanced output to PA Figure 2.1.7 CMU connecting to PA 2.1.3.3 To fiber device HCS-4100MA/50 has a pair of fiber interfaces, and can be connected to the HCS-4100MA/50, HCS-8300 series CMU/EMU, to the Audio Input Interface and to the Audio Output Device.
  • Page 31: Configuration And Operation

    2.1.4 Configuration and operation After installation and connection and prior to the meeting, the CMU should be configured through the dialog menu and button. The term “interface” used hereinafter means the information displayed on the LCD as the “user” interface. The menu structure is shown in the following figure: Figure 2.1.9 LCD menu structure of the congress main unit...
  • Page 32 A) Starting initialization active microphone (including chairman and VIP Switch press “STANDBY” button, unit) reaches 6, turning on another microphone will HCS-4100M/50 CMU will start initialization: switch off the delegate microphone which turned on first. “Voice”: The delegate’s microphone is activated when spoken into.
  • Page 33 C) Access main menu 2.1.4.1 Network Pressing the “MENU” button under initial user interface “Network” includes three submenus: will go to the main menu, which includes nine menu “IP Address” items: “Subnet Mask” “Network” “Gateway” “Simultaneous Interpretation” “System Status” “Test” “System Setting”...
  • Page 34 2.1.4.2 Simultaneous interpretation “Simultaneous Interpretation” submenu, Use the “/” button to switch among 0 - 63. Usually, following parameters need to be setup: one language will take one booth.  “Select Number of Channel(s):”  If “0” is selected, it stands for no SI function, use the ...
  • Page 35 1). Use the “/” button to switch between the interlock modes;  “OVERRIDE” mode enables an interpreter in a booth to override an occupied channel in the same booth, but supplying the same channel. 3). If ALL is selected for C then press the “/” ...
  • Page 36 2.1.4.3 System status “System status” submenu includes: “Unit status” “Interpretation status” 3). Press the “/” button to select auto-relay booth and press the “MENU” button to confirm, then the corresponding booth number will be highlighted and set as auto-relay booth. Press the “/” button to select next auto-relay booth until all auto-relay booths have been set;...
  • Page 37 2.1.4.4 Test (cannot work under “Voice” and “PTT” mode) “Test” submenu includes: “Microphone” “LCD” Under channel state interface, press the “MENU” “Button” button to select the channel number or parameter and “Loudspeaker” press the “/” button to change the number or “LED”...
  • Page 38 d). When the first time line scan is finished, press any c). When the loudspeaker of every congress unit has button to start the second time line scan; been tested, press the “” or the “EXIT” button to e). When the second time line scan is finished, press exit loudspeaker test interface.
  • Page 39 2.1.4.5 System setting Loudspeaker Mute Setting “Setting” submenu includes: Mute/Not mute loudspeaker of congress units (except interpreter units). a). Press the “/” button to select mute or not; b). Press the “MENU” button to save and return to the upper level menu. LINE IN 1 Mode Setting Select LINE IN 1 mode from “Line input”...
  • Page 40 b). Press the “MENU” button to save and return to the LINE IN 2 Volume Setting upper level menu. Adjust LINE IN 2 input volume, range: mute, -30 dB - 0 Note:  “Down” and “downlink” used in 5./6. and 7. indicate the signal transmission direction from the main unit to the congress units.
  • Page 41 If it is not ok then keep the microphone switched on a). Press the “/” button to select “Set All Mics” or and got to “Set Active” setting in the CMU and increase “Single”; or decrease the microphone gain. b). Press the “MENU” button to go to the next step: Continue with the next microphone.
  • Page 42 a). Press the “/” button to select monitor channel; b). Press the “/” button to select priority mode b). Press the “MENU” button to save and return to the between “All Mute” and “All Off”;  “All Mute”: when chairman presses and holds upper level menu.
  • Page 43 a). Press the “/” button to set auto turn off time 18. Time Setting (press and hold the “/” button will adjust Set system clock. numeric value quickly); range: 300 ms /600 ms /1 s - 15 s. b). Press the “MENU” button to save and return to the upper level menu.
  • Page 44 At this instant, all contribution units with an LCD will a). Press the “/” button to select “Yes” or “No”; prompt the number on their LCD; contribution units b). Press the “MENU” button to save and return to the without LCD will activate the corresponding LED. upper level menu.
  • Page 45 a). Press the “/” button to select “Master Mode” or frequency is 30 Hz - 16 kHz. “Slave Mode”:  If “Master Mode” is selected, press the “MENU” button to confirm and return to the upper level menu;  If “Slave Mode” is selected, press the “MENU” a).
  • Page 46 a). Press the “/” button to select “Yes” or “No”; a). Press the “/” button to select “Yes” or “No”; b). Press the “MENU” to save and return to the upper b). Press the “MENU” button to save and return to the level menu.
  • Page 47 d). Press any button to return to the main menu. a). Press the “/” button to select “On” or “Off”; b). Press the “MENU” button to save and return to the upper level menu. 34. Mic. LED Setting Control the illuminated ring (green) of the stem 36.
  • Page 48 LineOut; 40. DDS Units Setting  Sync. Line Out1 Mixer: Adjust the audio Set work mode for HCS-xxxxDDS: parameters (Conference Management System - Setup - Audio Output Setup) of LineOut1 and the floor signal via Mixer 1 synchronously, see figure 2.1.12.
  • Page 49 d). Press the “MENU” button to confirm the operation 44. Line out1 Noise Gate Setting and return to the upper level menu. Enable Line out1 noise gate to reduce background noise. 42. Alarm Setting Enable the “ALARM” interface in the backside of HCS-8300M series congress unit.
  • Page 50 Figure 2.1.10 Floor mode setting - Normal Mode Figure 2.1.11 Floor mode setting - Insert Mode...
  • Page 51 Figure 2.1.12 Floor mode setting - Sync. Line Out1 Mixer...
  • Page 52 2.1.4.8 Machine rename 2.1.4.6 Operation language setting Set alias for the HCS-4100M/50 with a maximum length of 16 characters or less. It is convenient to identify them on the operation of room combiner. Select LCD display language from simplified Chinese, Traditional Chinese and English.
  • Page 53 2.1.4.11 Power Management 2.1.4.13 Configuration and operation - slave mode Press and hold the “STANDBY” button to enter power management interface, as shown as the following When dual main unit hot spare or conference room figure: combination occurs, the spare main unit or the main unit in the slave conference room works in slave mode.
  • Page 54: Extension Main Unit

    2.2 Extension Main Unit 2.2.1 Functions and instructions Front panel Backside of HCS-8300ME/FS Backside of HCS-8300ME Figure 2.2.1 HCS-8300 series extension main unit Figure 2.2.1: 1. Overload indicator 6. Fiber output (with switch)  Normal: turn off;  Single-mode optical fiber, SC connector. ...
  • Page 55: Installation

    2.2.2 Installation The extension main unit (EMU) can be fixed in a standard 19-inch cabinet. The EMU is equipped with a pair of fixing brackets ①. First unscrew the lateral screws ② from the housing. Then fasten the brackets with these screws and put the EMU in the cabinet. Finally fix the four holes ③...
  • Page 56: Connection

    2.2.3 Connection HCS-8300 series CMU has two 6P-DIN output Each extension main unit has an extension input port interfaces; the power capacity of each 6P-DIN interface for connecting to extension interface of the congress is limited. If the actually needed power of the system main unit, another...
  • Page 57: Chapter 3: Congress Units

    Chapter 3: Congress units 3.1 Overview Congress unit is the common name to describe the HCS-48U6DVOTTW units used by the attendees to contribute to a congress. Fully Digital Voting Unit (flush-mounting, 3 voting keys, The term includes discussion unit (chairman/delegate), contactless IC-Card reader, HCS-48U6SELM or HCS-48U6MICM voting unit, channel selector etc.
  • Page 58 HCS-4340CU/50 HCS-48U9DFFN/52 Multi-function Connector (for HCS-48U7 series, for connection to Fully Digital Congress System Delegate Unit (flush-mounting, 5 1 chairman unit + 1 loudspeaker, black) voting keys, contactless IC-Card reader, 64 CHs, 256x32 LCD, HCS-4340CUN/52 can be connected with E-ink electronic nameplate, black) HCS-48U9DVP Multi-function Connector (for HCS-48U7 series, for connection to 1 chairman unit + 1 loudspeaker, can be connected with E-ink...
  • Page 59 HCS-4887DW/50 HCS-4363D/50 HCS-4887DW/52 Fully Digital Congress System Delegate Unit (flush-mounting, Fully Digital Congress System Delegate Unit (tabletop, 5 voting cover, charcoal gray) keys, contactless IC-Card reader, 256x32 LCD) HCS-4888DE/50 HCS-4338N series congress units: HCS-4888DE/52 HCS-4338NCVS/50 Fully Digital Congress System Delegate Unit (tabletop, 5 voting Fully Digital Congress System Chairman Unit (tabletop, 3 voting keys) keys, 64 CHs, OLED)
  • Page 60 HCS-4860/2M series congress units: HCS-4866DS/50 Fully Digital Congress System Delegate Unit (tabletop, 64 CHs, HCS-4860CS/50/2M OLED) Fully Digital Congress System Chairman Unit (tabletop, 64 CHs, HCS-4866C/50 OLED, rectangular columnar metal microphone, main Fully Digital Congress System Chairman Unit (tabletop) microphone + backup microphone, silver microphone + black HCS-4866D/50 base) Fully Digital Congress System Delegate Unit (tabletop)
  • Page 61 HCS-4325/26/27 series congress units: HCS-4841ND/50 Fully Digital Congress System Delegate Unit (flush-mounting, HCS-4325U/50 HCS-4340/50 needed) Dual 64-Channel Selector (flush-mounting, black) HCS-4841CU/50 HCS-4325(N)/50 Fully Digital Congress System Chairman Unit (flush-mounting, Dual 64-Channel Selector (flush-mounting) HCS-4340/50 needed) HCS-4325(N)W/50 HCS-4841DU/50 Dual 64-Channel Selector (flush-mounting, contactless IC-Card Fully Digital Congress System Delegate Unit (flush-mounting, reader) HCS-4340/50 needed)
  • Page 62 HCS-4368DFW/50 HCS-4340HDAF/50P Fully Digital Voting System Delegate Unit (tabletop, 5 voting keys, Multi-function Connector (for connection to 1 condenser 256x32 LCD, waterproof, antistatic 12000 V, contactless IC-Card microphone + 1 5-key voting unit + 1 channel selector, +48 V reader) phantom power, charcoal gray) HCS-4368CF/FM/50 HCS-4340B/50...
  • Page 63: Hcs-48U6 Series Congress Unit

    3.2 HCS-48U6 series congress unit 3.2.1 Functions and indications HCS-48U6CMICM flush-mounted chairman unit HCS-48U6DMICM flush-mounted delegate unit HCS-48U6CMICMS flush-mounted chairman unit HCS-48U6DMICMS flush-mounted delegate unit HCS-48U6SELM flush-mounted channel selector HCS-48U6SPK HCS-48U6DVOTTW flush-mounted voting unit HCS-48U6DVOTFW flush-mounted voting unit Bottom of HCS-48U6MICM Bottom of HCS-48U6MICMS Bottom of HCS-48U6SELM Bottom of HCS-48U6DVOT...
  • Page 64 Figure 3.2.1: 1. Stem microphone socket 7. Earphone volume control 8. Multi-function keys with indicating light (3 keys): 2. Priority key with indicating light (for the  In different modes, the corresponding indicating chairman unit only):  According to the priority mode configuration on the lights blink;...
  • Page 65 Table 3.2.1 List of multi-functional keys - 3 keys Function Keys ABSTAIN Numbering Number Sign-in Sign-in Parliamentary ABSTAIN For/Against Against Satisfied/ Basically satisfied/ Unsatisfied/ 3 keys voting Qualified/ Basically qualified/ Unqualified/ Competent Basically competent Incompetent Satisfied/ Unsatisfied/ 2 keys voting Qualified/ Unqualified/ Competent...
  • Page 66: Installation

    3.2.2 Installation 3.2.2.1 Stand-alone installation ■ Installation a. Make holes on the table according to the dimensional diagram; b. Fix the fixed iron plates with self tapping screws (KA3×12) according to the holes; c. Hook up the unit onto the fixed iron plates. Figure 3.2.4 Disassembly caution of HCS-48U6 series flush-mounted congress unit Figure 3.2.2 Positioning diagram of HCS-48U6 series...
  • Page 67 Figure 3.2.6 Installation diagram of HCS-48U6SPK...
  • Page 68 3.2.2.2 Assembly installation a. Cut holes in the table for the first unit according to the positioning diagram (figure 3.2.7); b. Make sure that the distance between the center of the two adjacent holes is more than 100 mm; and distance center between...
  • Page 69: Connection

    3.2.3 Connection 3.2.3.1 Connecting to the CMU or the EMU Loop - Daisy Chain” connection, but only one – HCS-48U6 series (HCS-48U6MICM extension units do not offer this feature. HCS-48U6SELM) congress unit is equipped with a 1.5-meter 6P-DIN cable with a standard male connector.
  • Page 70 3.2.3.3 External earphone An external earphone can be connected to the earphone jack of HCS-48U6SELM channel selector. Its volume can be adjusted by the earphone volume control button. The external earphone shall have Ø 3.5 mm plug, as the following figure: Functions and indications: Left stereo channel signal Right stereo channel signal...
  • Page 71: Operation

    3.2.4 Operation Before a meeting starts, the congress units need to be  IC-Card sign-in configured by the operator, including: numbering and In IC-Card sign-in status, please put the contactless testing. During the meeting, the participators use the IC-card into the slot on the voting unit. If read the congress unit to sign-in, activate microphone, request IC-Card correctly, the indicating light will off after to speak, vote, etc.
  • Page 72 4. Voting (for HCS-48U6DVOT series only) All other microphones cannot be activated unless Voting can be originated by TAIDEN conference one of the active microphones is turned off. management system software.  The voting button indicating lights of the congress D.
  • Page 73 7. VIP unit (for delegate discussion unit of this series only)  Any delegate unit can be assigned as a VIP unit by the TAIDEN conference management system software. At most 32 VIP units can be assigned;  As long as the active microphone capacity is not full, the microphone of the VIP unit can be activated freely;...
  • Page 74 3.2.4.2 Chairman unit The chairman unit features all the functions of a delegate unit, and the following additional functions: 1. Priority (for chairman discussion unit of this series only)  If the priority mode on the main unit is configured as “All mute”, all active delegate microphones (except VIP units) will be muted temporarily when this key is pressed and they will restore when this...
  • Page 75: Hcs-48U7/U8/U9 Series Congress Unit

    3.3 HCS-48U7/U8/U9 series congress unit 3.3.1 Functions and indications HCS-48U9 series front HCS-48U9CFF HCS-48U9DFF HCS-48U9CFFN/52 HCS-48U9DFFN/52 HCS-48U9DVP HCS-48U8 series front HCS-48U8CFF HCS-48U8DFF HCS-48U8CFFN/52 HCS-48U8DFFN/52 HCS-48U7 series front HCS-48U7VOTF HCS-48U7CMIC HCS-48U7DMIC HCS-48U7SEL HCS-48U7SPK HCS-48U7VOTFN/52...
  • Page 76 HCS-48U7CMICSPK HCS-48U7DMICSPK HCS-48U7/U8/U9 series side and back Back side Left side Right side Figure 3.3.1 HCS-48U7/U8/U9 series congress units Figure 3.3.1:  If the chairman microphone is not active, pressing 1. Built-in Hi-Fi loudspeaker  Mutes automatically to suppress howling when the this key will activate it;...
  • Page 77 11. High light 256x32 graphic LCD  Can display menu and information in several languages (Simplified Chinese, Traditional Chinese, English, etc.);  If the earphone is plugged, the simultaneous interpretation channel number and the language name will be displayed. 12. Mic. (RJ11 socket) (refer to figure 3.3.13 and figure 3.3.14 for details) ...
  • Page 78 Table 3.3.1 List of multi-function keys Function Keys 1/- - 5/++ Numbering Number Key-press sign-in Sign-in Start/End Start/End (with application software) Pause/End (without Pause application software) Parliamentary ABSTAIN Questionnaire Audience response --/0 -/25 0/50 +/75 ++/100 For/Against Against Parliamentary ABSTAIN NPPV Perfectly Unsatisfied...
  • Page 79: Installation

    3.3.2 Installation 3.3.2.1 Cutout Figure 3.3.2 Cutout of HCS-48U7 series flush-mounted congress unit (unit: mm)
  • Page 80 Figure 3.3.3 Cutout of HCS-48U8 series flush-mounted congress unit (unit: mm)
  • Page 81 Figure 3.3.4 Cutout of HCS-48U9 series flush-mounted congress unit (unit: mm)
  • Page 82 Figure 3.3.5 Cutout of HCS-48U7MICSPK flush-mounted congress unit (unit: mm)
  • Page 83 3.3.2.2 Installation Figure 3.3.6 Installation of HCS-48U7 series flush-mounted congress unit...
  • Page 84 Figure 3.3.7 Installation of HCS-48U8 series and HCS-48U9 series flush-mounted congress unit...
  • Page 85 Figure 3.3.8 Installation of HCS-48U7MICSPK series flush-mounted congress unit...
  • Page 86 3.3.2.3 Disassembly Figure 3.3.9 Disassembly of HCS-48U8 and HCS-48U9 series flush-mounted congress unit (method a) Figure 3.3.10 Disassembly of HCS-48U8 and HCS-48U9 series flush-mounted congress unit (method b)
  • Page 87 Figure 3.3.11 Disassembly caution of HCS-48U8 and HCS-48U9 series flush-mounted congress unit...
  • Page 88: Connection

    3.3.3 Connection 3.3.3.1. Connection among the modules of HCS-48U7 congress unit Figure 3.3.12 Connection among the modules of HCS-48U7 congress unit...
  • Page 89 3.3.3.2. Connection between HCS-48U7MICSPK congress unit and HCS-4340U/52 multi-function connector Figure 3.3.13 Connection between HCS-48U7MICSPK congress unit and HCS-4340U/52 multi-function connector...
  • Page 90 3.3.3.3 Connecting to the CMU or the EMU HCS-48U7/U8/U9 series congress unit equipped with a 1.5-meter 6P-DIN cable with a standard male connector (HCS-48U7MICSPK series congress unit shall be connected to the multi-function connector). To connect to the HCS-4100/50 CMU or the HCS-8300 EMU, just connect the male connector of the first unit to the output of the main unit.
  • Page 91 3.3.3.5 External microphone An external microphone can be connected to the external microphone jack of the congress unit. The external microphone shall have a Ø 3.5 mm plug, as in the following figure: Functions and indications: Signal+ Suspend/Ground Ground 3.3.3.6 External earphone An external earphone can be connected to the external earphone jack of the congress unit.
  • Page 92: Operation

    3.3.4 Operation  Key-press sign-in Before a meeting starts, the congress units need to be configured by the operator, including: numbering and In key-press sign-in status, the indicating light on key testing. During the meeting, the participators use the “1” will blink, press key “1” to sign-in and the indicating congress unit to sign-in, activate microphone, request light will be turned off.
  • Page 93 In the above sign-in mode (except key press sign-in active microphone (including chairman and VIP mode), logout is available. It is used for locking the unit) reaches 6, turning on another microphone will units in case the delegates leave for a short time. switch off the delegate microphone which turned Delegate units will work on after delegates sign-in on first.
  • Page 94  Use this key to read a message. When a PC is Voting can be originated by the chairman unit (only for connected, the operator can edit and send a 3 keys voting), or by TAIDEN conference management message to congress unit(s); system software.
  • Page 95 If not, it will remind you to plug the earphone. If the current unit is using the intercom function, it will the TAIDEN conference management system remind you that the line is busy. Press “Call” (key “1”) to software. At most 32 VIP units can be assigned;...
  • Page 96 3.3.4.2 Chairman unit (key “3”) to go to the microphone status interface as in the following figure at the right side: The chairman unit features all the functions of a delegate unit, and the following additional functions: 1. Priority  Press “Active” (key “1”) to go to the active ...
  • Page 97 and only “Last key-press valid” is available. The chairman can pause/end voting: d. The chairman presses “End” (key “5”) to finish voting. The voting indicating light of all congress units will be deactivated. The voting results and sign-in statistics will be displayed on the chairman unit: B.
  • Page 98: Hcs-48U10 Series Congress Unit

    3.4 HCS-48U10 series congress unit 3.4.1 Functions and indications HCS-48U10CVS(N) chairman unit HCS-48U10DVS(N) delegate unit HCS-48U10DV delegate unit HCS-48U10DDS delegate unit Side HCS-48U10DDS delegate unit Bottom Figure 3.4.1 HCS-48U10 series congress units Figure 3.4.1: ◊ If configured as “All off”, all active delegate 1.
  • Page 99  If the ring mode is configured as “ON”, a ring tone 5. Contactless IC Card slot  Built-in contactless IC-Card slot to place the IC will be produced when this key is pressed. 2. Microphone On/Off key with indicating light (for card, while automatically logout once the card is taken out from the slot.
  • Page 100: Installation

    3.4.2 Installation Figure 3.4.2 Cutout of HCS-48U10 series congress unit (unit: mm)
  • Page 101 Figure 3.4.3 Installation of HCS-48U10 series congress unit...
  • Page 102: Connection

    3.4.3 Connection 3.4.3.1 Connecting to the CMU or the EMU The HCS-48U10 series congress unit is equipped with a 1.5-meter 6P-DIN cable with a standard male connector. To connect to the HCS-4100/50 CMU or the HCS-8300 EMU, just connect the male connector of the first unit to the output of the main unit.
  • Page 103 3.4.3.3 External earphone An external earphone can be connected to the external earphone jack of the congress unit. Its volume can be adjusted by the earphone volume control button. The external earphone shall have a Ø 3.5 mm plug, as the following figure: Functions and indications: Left stereo channel signal...
  • Page 104: Operation

    3.4.4 Operation 2. Sign-in (application software needed) Before a meeting starts, the congress units need to be configured by the operator, including: numbering and To carry out voting, congress units with voting and testing. During the meeting, the participators can use IC-Card reader should be registered via key press or the congress unit to sign-in, activate microphone, IC-Card.
  • Page 105  Active microphone number limitation (1/2/3/4)  Active microphone number limitation (1/2/3/4) reached: reached: a. Press the microphone On/Off key to request to All other microphones cannot be activated unless speak; one of the active microphones is turned off. b. Press the microphone On/Off key again to cancel the request to speak;...
  • Page 106 Voting (only HCS-48U10CVS(N), HCS-48U10DVS(N) and HCS-48U10DV)  “YES” key: page up Voting can be originated by TAIDEN conference  “NO” key: page down management system software. Only supports  parliamentary voting: Yes/No/Abstain, and For/Against “ABSTAIN” key: enter voting.  The voting button indicating lights of the congress A.
  • Page 107 3.4.4.2 Chairman unit The chairman unit features all the functions of a 4. Voting delegate unit, and the following additional functions: HCS-48U10CVS(N) chairman unit cannot originate 1. Priority voting without a PC:  Nominative or ballot voting are available;  If the priority mode on the main unit is configured ...
  • Page 108: Hcs-4886/87/88 Series Congress Unit

    3.5 HCS-4886/87/88 series congress unit 3.5.1 Functions and indications HCS-4886CW/50 chairman unit HCS-4886DW/50 and HCS-4887DW/50 delegate unit HCS-4886CW(N)/52 chairman unit HCS-4886DW(N)/52 and HCS-4887DW/52 delegate unit HCS-4888DE/50 delegate unit HCS-4886NX/50 operator unit HCS-4888DE/52 delegate unit HCS-4886NX/52 operator unit Left side Right side Backside of HCS-4886WN/52 Backside of HCS-4886/87/88 series congress unit Figure 3.5.1 HCS-4886/87/88 series congress units...
  • Page 109 Figure 3.5.1: 1. Multi-function keys with indicating light (5 keys): interpretation channel number and the language  In different modes, the corresponding indicating name will be displayed (HCS-4887DW does not lights blink; press the corresponding key to have this function). execute operation (refer to table 3.5.1 for details);...
  • Page 110 Table 3.5.1 List of multi-functional keys Function Keys 1/- - 5/++ Numbering Number Key-press sign-in Sign-in Start/End Start/End (with application software) Pause/End (without Pause application software) Parliamentary ABSTAIN Questionnaire Audience response --/0 -/25 0/50 +/75 ++/100 For/Against Against Parliamentary (NPPV) ABSTAIN NPPV Perfectly...
  • Page 111: Connection

    3.5.2 Connection 3.5.2.1 Connecting to the CMU or the EMU The HCS-4886/87/88 series congress unit is equipped with a 1.5-meter 6P-DIN cable with a standard male connector. To connect to the HCS-4100/50 CMU or the HCS-8300 EMU, just connect the male connector of the first unit to the output of the main unit.
  • Page 112 3.5.2.3 External microphone An external microphone can be connected to the external microphone jack of the congress unit. The external microphone shall have a Ø 3.5 mm plug, as in the following figure: Functions and indications: Signal+ Suspend/Ground Ground 3.5.2.4 External earphone An external earphone can be connected to the external earphone jack of the congress unit.
  • Page 113: Operation

    3.5.3 Operation  Key-press sign-in Before a meeting starts, the congress units need to be configured by the operator, including: numbering and In key-press sign-in status, the indicating light on key testing. During the meeting, the participators use the “1” will blink, press key “1” to sign-in and the indicating congress unit to sign-in, activate microphone, request light will be turned off.
  • Page 114 In the above sign-in mode (except key press sign-in switch off the delegate microphone which turned mode), logout is available. It is used for locking the on first. units in case the delegates leave for a short time. Delegate units will work on after delegates sign-in C.
  • Page 115 After sign-in, the following interface will be displayed on the LCD: 4. Voting Voting can be originated by the chairman unit (only for 3 keys voting), or by TAIDEN conference management system software.  The voting button indicating lights of the congress A. “Message” (key “1”) unit start to blink, the delegate can press the voting button to vote;...
  • Page 116  Any delegate unit can be assigned as a VIP unit by If the current unit is using the intercom function, it will the TAIDEN conference management system remind you that the line is busy. Press “Call” (key “1”) to software.
  • Page 117 3.5.3.2 Chairman unit (key “3”) to go to the microphone status interface as in the following figure at the right side: The chairman unit features all the functions of a delegate unit, and the following additional functions: 1. Priority  If the priority mode on the main unit is configured ...
  • Page 118 c. Only 3 keys voting can be executed in case of a chairman unit originated voting (“Yes/No/Abstain”) and only “Last key-press valid” is available. The chairman can pause/end voting: d. The chairman presses “End” (key “5”) to finish voting. The voting indicating light of all congress units will be deactivated.
  • Page 119 3.5.3.3 Operator unit  Press “Mic” (key “1”) to display the microphone The operator unit is a dedicated unit used by an information, including: active microphone number operator to control the intercom function. Its initial (including chairman, delegate and VIP), request interface is shown in the following figure: amount: Press the “5”...
  • Page 120: Hcs-4380/82/70/71 Series Congress Unit

    3.6 HCS-4380/82/70/71 series congress unit 3.6.1 Functions and indications HCS-4380SCW/50 chairman unit HCS-4380SDW/50 delegate unit HCS-4382SD/50 delegate unit HCS-4370SDWE/50 delegate unit Left side HCS-4371SD/50 delegate unit Back Figure 3.6.1 HCS-4380/82/70/71 series discussion units...
  • Page 121 Figure 3.6.1: 1. Earphone volume control 9. Built-in Hi-Fi loudspeaker  Mutes automatically to suppress howling when the 2. Multi-function keys with indicating light (5 keys):  In different modes, the corresponding indicating microphone of the unit is active;  Loudspeaker sends out floor channel audio only. lights blink;...
  • Page 122 Table 3.6.1 List of multi-functional keys Function 1/- - 5/++ Keys Numbering Number Sign-in Key-press sign-in Start/End (with application Start/End software) Pause/End (without Pause application software) ABSTAIN Parliamentary Questionnaire Audience --/0 -/25 0/50 +/75 ++/100 For/Against Against Parliamentary ABSTAIN NPPV Perfectly Satisfied Basically satisfied...
  • Page 123: Connection

    3.6.2 Connection 3.6.2.1 Connecting to the CMU or the EMU The HCS-4380/82/70/71 series congress unit is equipped with a 1.5-meter 6P-DIN cable with a standard male connector. connect HCS-4100/50 CMU or the HCS-8300 EMU, just connect the male connector of the first unit to the output of the main unit.
  • Page 124 3.6.2.3 External microphone An external microphone can be connected to the external microphone jack of the congress unit. The external microphone shall have a Ø 3.5 mm plug, as in the following figure: Functions and indications: Signal+ Suspend/Ground Ground 3.6.2.4 External earphone An external earphone can be connected to the external earphone jack of the congress unit.
  • Page 125: Operation

    3.6.3 Operation  Key-press sign-in Before a meeting starts, the congress units need to be configured by the operator, including: numbering and In key-press sign-in status, the indicating light on key testing. During the meeting, the participators use the “1” will blink, press key “1” to sign-in and the indicating congress unit to sign-in, activate microphone, request light will be turned off.
  • Page 126  Seat IC-Card and PIN code sign-in  Active microphone number limitation (1/2/3/4) reached: In seat IC-Card and PIN code sign-in status, “Please If the delegate microphone On/Off key is pressed, Use IC Card” and PIN code input interface will be its microphone will be activated and the first displayed on the LCD.
  • Page 127  Use this key to read a message. When a PC is Voting can be originated by the chairman unit (only for connected, the operator can edit and send a 3 keys voting), or by TAIDEN conference management message to congress unit(s). system software.
  • Page 128  Any delegate unit can be assigned as a VIP unit by function. If not, it will remind you to plug the earphone. the TAIDEN conference management system If the current unit is using the intercom function, it will software. At most 32 VIP units can be assigned;...
  • Page 129 3.6.3.2 Chairman unit (key “3”) to go to the microphone status interface as in the following figure at the right side: The chairman unit features all the functions of a delegate unit, and the following additional functions: 1. Priority  If the priority mode on the main unit is configured ...
  • Page 130 c. Only 3 keys voting can be executed in case of a chairman unit originated voting (“Yes/No/Abstain”) and only “Last key-press valid” is available. The chairman can pause/end voting: d. The chairman presses “End” (key “5”) to finish voting. The voting indicating light of all congress units will be deactivated.
  • Page 131: Hcs-4360/61/62/63 Series Congress Unit

    3.7 HCS-4360/61/62/63 series congress unit 3.7.1 Functions and indications HCS-4360CWE/50 chairman unit HCS-4360DWE/50 delegate unit HCS-4361DE/50 delegate unit HCS-4362D/50 delegate unit HCS-4363D/50 delegate unit Right side Protective cover Figure 3.7.1 HCS-4360/61/62/63 series congress units...
  • Page 132 Figure 3.7.1:  If the chairman microphone is not active, pressing 1. Earphone jack (Ø 3.5 mm) 2. Simultaneous interpretation channel - selector this key will activate it;  Available when the earphone is plugged.  If the ring mode is configured as “ON”, a ring tone 3.
  • Page 133 Table 3.7.1 List of multi-functional keys Function Keys 1/- - 5/++ Numbering Number Key-press sign-in Sign-in Start/End* Start/End Parliamentary ABSTAIN Questionnaire Audience response --/0 -/25 0/50 +/75 ++/100 For/Against Against Parliamentary ABSTAIN NPPV Perfectly Satisfied Basically satisfied Unsatisfied Satisfied satisfied (four (four/three/two (four/three keys (four/three/two...
  • Page 134: Installation

    3.7.2 Installation 3.7.2.1 Installation of HCS-4360/61/62/63 series 3.7.2.2 Installation of the protective cover of congress unit HCS-4360/61/62/63 series congress unit a. Cut a hole in the table according to the dimensions If not in use for a long time, just pull out the microphone in figure 3.7.2;...
  • Page 135: Connection

    3.7.3 Connection 3.7.3.1 Connecting to the CMU or the EMU The HCS-4360/61/62/63 series congress unit is equipped with a 1.5-meter 6P-DIN cable with a standard male connector. connect HCS-4100/50 CMU or the HCS-8300 EMU, just connect the male connector of the first unit to the output of the main unit.
  • Page 136 3.7.3.3 External earphone An external earphone can be connected to the external earphone jack of the congress unit. Its volume can be adjusted by the earphone volume control knob. The external earphone shall have a Ø 3.5 mm plug, as in the following figure: Functions and indications: Left stereo channel signal...
  • Page 137: Operation

    3.7.4 Operation Before a meeting starts, the congress units need to be 2. Sign-in (application software needed) configured by the operator, including: numbering and To carry out voting, congress units with voting and testing. During the meeting, the participators can use IC-Card reader should be registered via key press or the congress unit to sign-in, activate microphone, IC-Card.
  • Page 138 All other microphones cannot be activated unless have this function) one of the active microphones is turned off. Voting can be originated by TAIDEN conference management system software. D. “Apply” mode  The voting button indicating lights of the congress unit start to blink, the delegate can press the voting a.
  • Page 139 7. VIP unit  Any delegate unit can be assigned as a VIP unit by the TAIDEN conference management system software. At most 32 VIP units can be assigned;  As long as the active microphone capacity is not full, the microphone of the VIP unit can be activated freely;...
  • Page 140 3.7.4.2 Chairman unit The chairman unit features all the functions of a 4. Voting delegate unit, and the following additional functions: HCS-4360CW/50 chairman unit cannot originate voting 1. Priority without a PC:  If the priority mode on the main unit is configured ...
  • Page 141: Hcs-4338N/50 Series Congress Unit

    3.8 HCS-4338N/50 series congress unit 3.8.1 Functions and indications HCS-4338NCVS/50 chairman unit HCS-4338NDVS/50 delegate unit HCS-4338NDV/50 delegate unit HCS-4338NCS/50 chairman unit HCS-4338NDS/50 delegate unit HCS-4338NC/50 chairman unit Back of HCS-4338N/50 HCS-4338ND/50 delegate unit HCS-4338NDDS/50 delegate unit Figure 3.8.1 HCS-4338N/50 series congress units...
  • Page 142 Figure 3.8.1: 1. Priority key with indicating light (for the 4. Built-in Hi-Fi loudspeaker  Mutes automatically to suppress howling when the chairman unit only):  According to the priority mode configuration on the microphone of the unit is active; ...
  • Page 143: Connection

    3.8.2 Connection 3.8.2.1 Connecting to the CMU or the EMU The HCS-4338N/50 series congress unit is equipped with a 1.5-meter 6P-DIN cable with a standard male connector. To connect to the HCS-4100/50 CMU or the HCS-8300 EMU, just connect the male connector of the first unit to the output of the main unit.
  • Page 144 3.8.2.3 External earphone An external earphone can be connected to the external earphone jack of the congress unit. Its volume can be adjusted by the earphone volume control button. The external earphone shall have a Ø 3.5 mm plug, as the following figure: Functions and indications: Left stereo channel signal...
  • Page 145: Operation

    3.8.3 Operation Before a meeting starts, the congress units need to be 2. Sign-in (application software needed) configured by the operator, including: numbering and To carry out voting, congress units with voting testing. During the meeting, the participators can use (HCS-4338NCVS/50, HCS-4338NDVS/50 the congress unit to sign-in, activate microphone,...
  • Page 146 (only HCS-4338NCVS/50, a. Request to speak when the microphone On/Off HCS-4338NDVS/50 and HCS-4338NDV/50) key is pressed (default 6 microphones at most). Voting can be originated by TAIDEN conference The chairman unit can approve or reject his/her management system software. Only supports speak;...
  • Page 147  The volume of the built-in loudspeaker can be  Any delegate unit can be assigned as a VIP unit by adjusted by the master volume control knob on the the TAIDEN conference management system main unit; software. At most 32 VIP units can be assigned;...
  • Page 148 3.8.3.2 Chairman unit B. Turn off or mute delegate microphone The chairman unit features all the functions of a delegate unit, and the following additional functions: The chairman can use the priority key to execute “All mute” or “All off” operation. 1.
  • Page 149: Hcs-4860/4865/4866 Series Congress Unit

    3.9 HCS-4860/4865/4866 series congress unit 3.9.1 Functions and indications HCS-4860CVE/50 chairman unit HCS-4860DVE/50 delegate unit HCS-4860CS/50 chairman unit HCS-4860DS/50 delegate unit HCS-4860C/50 chairman unit HCS-4860D/50 delegate unit...
  • Page 150 HCS-4865DV/50 delegate unit HCS-4865CV/50 chairman unit HCS-4866DV/50 delegate unit HCS-4866CV/50 chairman unit HCS-4865CS/50 chairman unit HCS-4865DS/50 delegate unit HCS-4866CS/50 chairman unit HCS-4866DS/50 delegate unit...
  • Page 151 HCS-4865C/50 chairman unit HCS-4865D/50 delegate unit HCS-4866C/50 chairman unit HCS-4866D/50 delegate unit Back of HCS-4860/50 Back of HCS-4865/50 Back of HCS-4866/50 Note:the HCS-4866/50 series equipped with fixed gooseneck microphone. Figure 3.9.1a HCS-4860/4865/4866 series congress units...
  • Page 152 HCS-4860CS/50/2M chairman unit HCS-4860DS/50/2M delegate unit HCS-4860C/50/2M chairman unit HCS-4860D/50/2M delegate unit Back of HCS-4860/50/2M Figure 3.9.1b HCS-4860/50/2M series congress units...
  • Page 153 Figure 3.9.1: 1. Earphone jack (Ø 3.5 mm) Work state Indicating light 2. Multi-function keys with indicating light (3 keys): Microphone On Red (on)  In different modes, the corresponding indicating Speaking time limit Red (flash) lights blink; press the corresponding key to First in request list Green (flash) execute operation (refer to table 3.9.1 for details).
  • Page 154: Connection

    3.9.2 Connection 3.9.2.1 Connecting to the CMU or the EMU The HCS-4860/4865/4866 series congress unit is equipped with a 1.5-meter 6P-DIN cable with a standard male connector. connect HCS-4100/50 CMU or the HCS-8300 EMU, just connect the male connector of the first unit to the output of the main unit.
  • Page 155 3.9.2.3 Dual backup microphone high-end congress system solution Innovative dual-microphone congress unit, with build-in isolated main microphone and backup microphone. When the main microphone fails, the system switches to the backup microphone, so that the meeting can carry on smoothly. See figure 3.9.5. Functions and indications: 3.9.2.4 External earphone Left stereo channel signal...
  • Page 156: Operation

    3.9.3 Operation Before a meeting starts, the congress units need to be 2. Sign-in (application software needed) configured by the operator, including: numbering and To carry out voting, congress units with voting should testing. During the meeting, the participators can use be registered via key press.
  • Page 157 D. “Apply” mode 4. Voting (only for units with voting) a. Request to speak when the microphone On/Off Voting can be originated by TAIDEN conference key is pressed (default 6 microphones at most). management system software.
  • Page 158 7. VIP unit  Any delegate unit can be assigned as a VIP unit by the TAIDEN conference management system software. At most 32 VIP units can be assigned;  As long as the active microphone capacity is not full, the microphone of the VIP unit can be activated freely;...
  • Page 159 3.9.3.2 Chairman unit 4. Voting The chairman unit features all the functions of a delegate unit, and the following additional functions: Chairman unit with voting cannot originate voting without a PC. 1. Priority When connecting with PC software:  If the priority mode on the main unit is configured ...
  • Page 160: Hcs-4851/50 Series Congress Unit

    3.10 HCS-4851/50 series congress unit 3.10.1 Functions and indications HCS-4851C/50 chairman unit HCS-4851D/50 delegate unit Protect cover Lateral of HCS-4851/50 Figure 3.10.1 HCS-4851/50 series congress units Figure 3.10.1: 1. Manually controlled key for microphone retract Not first in request list Green (on) and raise VIP indication...
  • Page 161  If the chairman microphone is not active, pressing this key will activate it;  If the ring mode is configured as “ON”, a ring tone will be produced when this key is pressed. 4. Microphone array  Microphone can be used only after raised, microphone length: 200mm, inclined angle up to 30°.
  • Page 162: Installation

    3.10.2 Installation Figure 3.3.2 Installation of HCS-4851/50 series congress unit (unit: mm)
  • Page 163 Figure 3.3.3 Installation of HCS-4851/50 series congress unit...
  • Page 164: Connection

    3.10.3 Connection 3.10.3.1 Connecting to the CMU or the EMU The HCS-4851/50 series congress unit is equipped with a 1.5-meter 6P-DIN cable with a standard male connector. To connect to the HCS-4100/50 CMU or the HCS-8300 EMU, just connect the male connector of the first unit to the output of the main unit.
  • Page 165: Operation

    3.10.4 Operation b. The microphone will be deactivated when the Before a meeting starts, the congress units need to be microphone On/Off key is pressed again. configured by the operator, including: numbering and testing. During the meeting, the participators can use ...
  • Page 166 All other microphones cannot be activated unless  Any delegate unit can be assigned as a VIP unit by one of the active microphones is turned off. the TAIDEN conference management system software. At most 32 VIP units can be assigned; D. “Apply” mode ...
  • Page 167 3.10.4.2 Chairman unit The chairman unit features all the functions of a delegate unit, and the following additional functions: 1. Priority  If the priority mode on the main unit is configured as “All mute”, all active delegate microphones (except VIP units) will be muted temporarily when this key is pressed and they will restore when this key is released;...
  • Page 168: Hcs-4330/31/32/33/35 Series Congress Unit (Hcs-4330/50 Series)

    3.11 HCS-4330/31/32/33/35 series congress unit (HCS-4330/50 series) 3.11.1 Functions and indications HCS-4330CE/50 chairman unit HCS-4330DE/50 delegate unit Back side of HCS-4330/4332 /50 HCS-4332DE/50 delegate unit Left side of HCS-4330/4332 /50 Right side of HCS-4330/50 HCS-4331CB/50 chairman unit HCS-4331DB/50 delegate unit...
  • Page 169 HCS-4333CB/50 chairman unit HCS-4333DB/50 delegate unit HCS-4335D/50 delegate unit Back side of HCS-4331/4333/4335 /50 Left side of HCS-4331/4333/4335 /50 Right side of HCS-4331/4333/4335 /50 Figure 3.11.1 HCS-4330/50 series congress units Figure 3.11.1: “Apply” mode, pressing this key will clear the 1.
  • Page 170 2. Multi-functional keys with indicating light (5 5. Simultaneous interpretation channel number keys): display  In different modes, the corresponding indicating 6. Built-in Hi-Fi loudspeaker  Mutes automatically to suppress howling when the lights blink; press the corresponding key to execute operation (refer to table 3.11.1 for details).
  • Page 171: Connection

    3.11.2 Connection 3.11.2.1 Connecting to the CMU or the EMU The HCS-4330/50 series congress unit is equipped with a 2.1-meter 6P-DIN cable with a standard male connector. To connect to the HCS-4100/50 CMU or the HCS-8300 EMU, just connect the male connector of the first unit to the output of the main unit.
  • Page 172 3.11.2.3 External earphone An external earphone can be connected to the external earphone jack of the congress unit. Its volume can be adjusted by the earphone volume control button. The external earphone shall have a Ø 3.5 mm plug, as the following figure: Functions and indications: Left stereo channel signal...
  • Page 173: Operation

    3.11.3 Operation Before a meeting starts, the congress units need to be 2. Sign-in (application software needed) configured by the operator, including: numbering and To carry out voting, congress units with voting and testing. During the meeting, the participators can use IC-Card reader should be registered via key press or the congress unit to sign-in, activate microphone, IC-Card.
  • Page 174 All other microphones cannot be activated unless HCS-4335D/50 do not have this function) one of the active microphones is turned off. Voting can be originated by TAIDEN conference management system software. D. “Apply” mode  The voting button indicating lights of the congress unit start to blink, the delegate can press the voting a.
  • Page 175 7. VIP unit  Any delegate unit can be assigned as a VIP unit by the TAIDEN conference management system software. At most 32 VIP units can be assigned;  As long as the active microphone capacity is not full, the microphone of the VIP unit can be activated freely;...
  • Page 176 3.11.3.2 Chairman unit The chairman unit features all the functions of a 4. Voting delegate unit, and the following additional functions: HCS-4330C/50 chairman unit cannot originate voting 1. Priority without a PC:  When controlled application software,  If the priority mode on the main unit is configured nominative or ballot voting are available;...
  • Page 177: Hcs-4325/26/27 Series Congress Unit

    3.12 HCS-4325/26/27 series congress unit 3.12.1 Functions and indications HCS-4325W/50 dual 64-channel selector HCS-4325NW/50 dual 64-channel selector HCS-4325/50 dual 64-channel selector HCS-4325N/50 dual 64-channel selector HCS-4325U/50 dual 64-channel selector HCS-4326CWE/50 chairman unit HCS-4326NCWE/50 chairman unit HCS-4326DWE/50 delegate unit HCS-4326NDWE/50 delegate unit...
  • Page 178 HCS-4326DE/50 delegate unit HCS-4326NDE/50 delegate unit HCS-4327D/50 delegate unit Back side HCS-4327HD/50 delegate unit with handheld microphone HCS-4327HDA/50 delegate unit with handheld microphone Note: The HCS-4327/50 series congress unit is only operative with HCS-4325/26 series congress unit. Figure 3.12.1 HCS-4325/26/27 series congress units Figure 3.12.1: 1.
  • Page 179 13. Multi-functional keys with indicating light (5 19. Stem microphone socket  1.0 meter cable with 6P mini DIN plug, connecting keys):  In different modes, the corresponding indicating to microphone interface (6P mini DIN) lights blink; press the corresponding key to HCS-4325(W)/50 or HCS-4326D(W)E/50.
  • Page 180: Installation

    3.12.2 Installation 3.12.2.1 Installation of HCS-4325/26 series congress unit a. Cut a hole in the table according to the dimensions in figure 3.12.2 or figure 3.12.3; b. Put the congress unit with the cables into the hole. Fix the unit with the M3 Phillips screws. Figure 3.12.2 Installation of HCS-4325/26 series congress unit (except HCS-4325U/50) (unit: mm)
  • Page 181 Figure 3.12.3 Installation of HCS-4325U/50 congress unit (unit: mm)
  • Page 182 3.12.2.2 Installation of HCS-4325/26/27 series congress unit (with HCS-4327HD/50) a. Drill holes according to figure 3.12.4 and make sure d. Align these two parts and fix them with screws that the centers of these two holes be on a straight (special tool required).
  • Page 183 3.12.2.3 Installation of HCS-4325/26/27 series congress unit (with HCS-4327D/50) a. Drill holes according to figure 3.12.6 and make sure d. Align these two parts and fix them with screws. To that the centers of these two holes be on a straight avoid that the parts are moving away from each line;...
  • Page 184 3.12.2.4 Installation of HCS-4327HDA congress unit a. Drill one Ø 2 mm holes on installation surface; b. Fix the holder with the M3 Phillips screws, and then put the handheld microphone in the holder. Figure 3.12.8 Installation diagram of HCS-4327HDA/50...
  • Page 185: Connection

    3.12.3 Connection 3.12.3.1 Connecting to the CMU or the EMU The HCS-4325/26 series congress unit is equipped with a 1.5-meter 6P-DIN cable with a standard male connector. To connect to the HCS-4100/50 CMU or the HCS-8300 EMU, just connect the male connector of the first unit to the output of the main unit.
  • Page 186 3.12.3.3 External earphone An external earphone can be connected to the external earphone jack of the congress unit. Its volume can be adjusted by the earphone volume control button. The external earphone shall have a Ø 3.5 mm plug, as the following figure: Functions and indications: Left stereo channel signal...
  • Page 187: Operation

    3.12.4 Operation Before a meeting starts, the congress units need to be 2. Sign-in (application software needed) configured by the operator, including: numbering and To carry out voting, congress units with voting and testing. During the meeting, the participators can use IC-Card reader should be registered via key press or the congress unit to sign-in, activate microphone, IC-Card.
  • Page 188 4. Voting (only for HCS-4326/50 series) All other microphones cannot be activated unless Voting can be originated by TAIDEN conference one of the active microphones is turned off. management system software.  The voting button indicating lights of the congress D.
  • Page 189 7. VIP unit  Any delegate unit can be assigned as a VIP unit by the TAIDEN conference management system software. At most 32 VIP units can be assigned;  As long as the active microphone capacity is not full, the microphone of the VIP unit can be activated freely;...
  • Page 190 3.12.4.2 Chairman unit The chairman unit features all the functions of a delegate unit, and the following additional functions: 1. Speaking  If the active microphone capacity is not full,, the chairman can activate his/her microphone normally, the operation is the same as for the delegate unit; ...
  • Page 191: Hcs-4341/50 Series Congress Unit

    3.13 HCS-4341/50 series congress unit 3.13.1 Functions and indications 3.13.1.1 HCS-4341/50 series congress unit Front of HCS-4341CB/50 Front of HCS-4341DB/50 Bottom of HCS-4341B/50 HCS-4341HD/50 flush-mounted boundary chairman unit boundary delegate unit delegate unit Figure 3.13.1 HCS-4341/50 series congress units Figure 3.13.1: 1.
  • Page 192 3.13.1.2 HCS-4340/50 Series multi-function connector Front of HCS-4340CAT/50, HCS-4340DAT/50, HCS-4340CAF/50, HCS-4340DAF/50, Front of HCS-4340B/50 multi-function connector HCS-4340HDAT/50(P) and HCS-4340HDAF/50(P) multi-function connector Front of HCS-4340DT/50 multi-function connector Back of HCS-4340/50 multi-function connector Figure 3.13.2 HCS-4340/50 series multi-function connectors Figure 3.13.2: 1. Handheld Mic. (for HCS-4340HDAT/50(P) and 3.
  • Page 193: Installation

    3.13.2 Installation a. Drill a Ø 32 mm hole; b. Put the cylindrical base into the hole and fix it with special pad and screwed ring; c. Put the cable of the handheld microphone over the hole of the cylindrical base and push the handheld microphone into the cylindrical base and buckle it.
  • Page 194: Connection

    3.13.3 Connection 3.13.3.1 Multi-function connector connecting to The HCS-4340/50 series multi-function connector is the CMU or the EMU equipped with a 2.1-meter 6P-DIN cable with a standard male connector. connect When connecting to the CMU or the EMU, the HCS-4100/50 CMU or the HCS-8300 EMU, just HCS-4341/50 series congress unit shall be connected connect the male connector of the first unit to the to the multi-function connector, and the multi-function...
  • Page 195 3.13.3.3 Multi-function connector connected to congress unit The HCS-4341/50 series congress unit is equipped with Cat.5 cable with standard RJ45 plug. When connecting to the multi-function connector, just connect the RJ45 plug of the congress unit into the corresponding RJ45 socket of the multi-function connector.
  • Page 196 Figure 3.13.7 Multi-function connector connected to the HCS-4341/50 series congress unit...
  • Page 197: Operation

    3.13.4 Operation Before a meeting starts, the congress units need to be b. The microphone will be deactivated when the configured by the operator, including: numbering and microphone On/Off key is pressed again. testing. During the meeting, the participators can use ...
  • Page 198 All other microphones cannot be activated unless  Any delegate unit can be assigned as a VIP unit by one of the active microphones is turned off. the TAIDEN conference management system software. At most 32 VIP units can be assigned; D. “Apply” mode ...
  • Page 199 3.13.4.2 Chairman unit The chairman unit features all delegate functions, and the following additional functions: 1. Priority  If the priority mode on the main unit is configured as “All mute”, all active delegate microphones (except VIP units) will be muted temporarily when this key is pressed and they will restore when this key is released;...
  • Page 200: Hcs-4841/42/43 Series Congress Unit

    3.14 HCS-4841/42/43 series congress unit 3.14.1 Functions and indications HCS-4841NC/50 flush-mounted chairman unit HCS-4841ND/50 flush-mounted delegate unit HCS-4841CU/50 flush-mounted chairman unit HCS-4841DU/50 flush-mounted chairman unit HCS-4841CUA/50 flush-mounted chairman unit HCS-4841DUA/50 flush-mounted chairman unit HCS-4842N/50 flush-mounted channel selector HCS-4842NA/50 flush-mounted channel selector...
  • Page 201 HCS-4843NCTE/50 flush-mounted chairman voting unit HCS-4843NDTE/50 flush-mounted delegate voting unit HCS-4843NCFE/50 flush-mounted chairman voting unit HCS-4843NDFE/50 flush-mounted delegate voting unit Bottom of HCS-4841N/50 series Bottom of HCS-4841U/50 series Bottom of HCS-4841UA/50 series Bottom of HCS-4842N(A)/50 flush-mounted channel selector Bottom of HCS-4843N/50 series flush-mounted voting unit Figure 3.14.1 HCS-4841/42/43 series congress units...
  • Page 202 Figure 3.14.1: 1. Stem microphone socket Work state Indicating light 2. Priority key with indicating light (for the Microphone On Red (on) chairman unit only): Speaking time limit Red (flash)  According to the priority mode configuration on the 4. Earphone jack (Ø 3.5 mm) main unit: 5.
  • Page 203 Table 3.14.2 List of multi-functional keys - 5 keys Function Keys 1/- - 5/++ Numbering Number Key-press sign-in Sign-in Start/End* Start/End Parliamentary ABSTAIN Questionnaire Audience response --/0 -/25 0/50 +/75 ++/100 For/Against Against Parliamentary ABSTAIN NPPV Perfectly Satisfied Basically satisfied Unsatisfied Satisfied satisfied (four...
  • Page 204: Installation

    3.14.2 Installation 3.14.2.1 Installation of HCS-4841N/42N/43N series congress unit ■ Stand-alone installation a. Cut holes in the table according to the positioning diagram (figure 3.14.3); b. Put the congress unit with the cables into the hole. Fix the unit with the black M3 Phillips screws (figure 3.14.4);...
  • Page 205 c. Stick PVCs to them. 3.14.2.2 Installation of terminating panels for HCS-4841N/42N/43N series congress unit a. Put the terminating panel marked “L” at the left side and align it with the installed congress unit. Fix it with Note: the black M3 Phillips screws; ...
  • Page 206 3.14.2.3 Installation of the HCS-4841U/50 flush-mounted channel selector a. Cut holes in the table according to the positioning diagram (figure 3.14.8 - left); b. Put the congress unit with the cables into the hole and install according to figure 3.14.8 - right; Figure 3.14.8 Installation of the HCS-4841U/50 flush-mounted channel selector...
  • Page 207 3.14.2.4 Installation of the HCS-4841UA/50 flush-mounted channel selector a. Cut holes in the table according to the positioning diagram (figure 3.14.9); b. Put the congress unit with the cables into the hole and install according to figure 3.14.9; Figure 3.14.9 Installation of the HCS-4841UA/50 flush-mounted channel selector...
  • Page 208 3.14.2.5 Installation of the HCS-4842NA/50 flush-mounted channel selector a. Cut holes in the table according to the positioning diagram (figure 3.14.10 - left); b. Put the congress unit with the cables into the hole. Fix the unit with the black M3 Phillips screws (figure 3.14.10 - right);...
  • Page 209 3.14.2.6 Flush-mounted loudspeaker HCS-4841/42/43 series congress unit d. Take off the auxiliary installation shell; a. Cut holes in the table according to positioning diagram (figure 3.14.11); Figure 3.14.13 Diagram of the finished installation of the fixing plates of the HCS-4844/50 series flush-mounted Figure 3.14.11 Positioning diagram of HCS-4844/50 loudspeaker series flush-mounted loudspeaker (unit: mm)
  • Page 210: Connection

    3.14.3 Connection 3.14.3.1 Multi-function connector connected to The HCS-4841/50 series discussion unit equipped with the CMU or the EMU a 1.5-meter 6P-DIN cable with a standard male connector and a 0.6-meter 6P-DIN cable with a When connecting to the CMU or the EMU, the standard female connector.
  • Page 211 congress unit back to the CMU or the EMU with a 3.14.3.3 Multi-function connector connected to CBL6PP extension cable (the cable features a 6P-DIN HCS-4841N/42N/43N series, male connector at each end). In HCS-4100/50 series HCS-4841U/50 series system, the congress main unit can realize a “Closed HCS-4841UA/50 series congress unit Loop - Daisy Chain”...
  • Page 212 Figure 3.14.18 Multi-function connector connected to HCS-4841/42/43 series congress units...
  • Page 213: Operation

    3.14.4 Operation Before a meeting starts, the congress units need to be 3. Speaking (without software, only for discussion unit configured by the operator, including: numbering and of this series) testing. During the meeting, the participators use the Speaking mode is configured on the CMU. (refer to congress unit to sign-in, activate microphone, request section 2.1.4) to speak, vote, etc.
  • Page 214 4. Voting (for HCS-4843N/50 series only) D. “Apply” mode Voting can be originated by TAIDEN conference a. Request to speak when the microphone On/Off management system software. key is pressed (default 6 microphones at most).
  • Page 215 7. VIP unit (for delegate discussion unit of this series only)  Any delegate unit can be assigned as a VIP unit by the TAIDEN conference management system software. At most 32 VIP units can be assigned;  As long as the active microphone capacity is not full, the microphone of the VIP unit can be activated freely;...
  • Page 216 3.14.4.2 Chairman unit The chairman unit features all the functions of a delegate unit, and the following additional functions: 4. Voting (for HCS-4843NC/50 series only) 1. Priority (for chairman discussion unit of this series HCS-4843N/50 series chairman unit cannot originate only) voting without a PC: ...
  • Page 217: Hcs-4368/50 Series Wired Voting Units

    3.15 HCS-4368/50 series wired voting units 3.15.1 Functions and indications Front panel of HCS-4368F/50 series 5 voting unit Front panel of HCS-4368FW/50 series 5 voting unit Side view of HCS-4368/50 tabletop voting unit Side view of HCS-4368/50 flush-mounted voting unit Figure 3.15.1 HCS-4368/50 series wired voting units Figure 3.15.1: 1.
  • Page 218 Table 3.15.1 List of multi-functional keys Function Keys 1/- - 5/++ Numbering Number Key-press sign-in Sign-in Start/End Start/End Parliamentary ABSTAIN Questionnaire Audience response --/0 -/25 0/50 +/75 ++/100 For/Against Against Parliamentary ABSTAIN NPPV Perfectly Satisfied Basically satisfied Unsatisfied Satisfied satisfied (four (four/three/two (four/three keys (four/three/two...
  • Page 219: Installation

    3.15.2 Installation 3.15.2.2 Installation of the protective cover of 3.15.2.1 Flush-mounted installation HCS-4368/50 series flush-mounted HCS-4368/50 series voting unit voting unit a. Cut a hole in the table according to the dimensions If not in use for a long time, just pull out the microphone in figure 3.15.2;...
  • Page 220: Connection

    3.15.3 Connection 3.15.3.1 Connecting to CMU or EMU The HCS-4368/50 series voting unit is equipped with a 1.5-meter 6P-DIN cable with a standard male connector. To connect to the HCS-4100/50 CMU or the HCS-8300 EMU, just connect the male connector of the first unit to the output of the main unit.
  • Page 221: Operation

    3.15.4 Operation Before a meeting starts, the congress units must be 2. Sign-in (application software needed) configured by the operator, including: numbering and To carry out voting, congress units with voting and testing. During the meeting, the participators use the IC-Card reader should be registered via key press, voting unit to sign-in and to vote.
  • Page 222 3. Voting Voting can be originated by the chairman unit (only for 3 keys voting), or by TAIDEN conference management system software. It is used for locking the units in case the delegates  The voting button indicating lights of the congress leave for a short time.
  • Page 223 3.15.4.2 Chairman unit The chairman unit features all the functions of a B. Voting with PC delegate unit, and the following additional functions:  When controlled by the application software, A. Voting without PC nominative or ballot voting are available; ...
  • Page 224: Hcs-1080 Series E-Ink Nameplate

    6. Micro USB interface 7. E-ink screen  Contents may be permanently displayed after power down;  Double screens, the contents can be set by the TAIDEN conference management software. 8. Mini 6P-DIN socket (female x 4)  For connection four...
  • Page 225: Installation

    3.16.2 Installation Figure 3.16.2 Installation of HCS-1080 electronic nameplate...
  • Page 226: Connection

    3.16.3 Connection 3.16.3.1 Connection between nameplate and Neither the replacement of nameplate adaptors nor congress unit cable faults between nameplate adaptors will affect the other units if “Closed Loop - Daisy Chain” connection The HCS-1080 nameplate is equipped with a cable topology is selected.
  • Page 227 Figure 3.16.5 “Daisy-chain” connection between HCS-1080T nameplate adaptors Figure 3.16.6 Connection of HCS-1080 E-ink Nameplate (with HCS-48U8 series congress unit) Figure 3.16.7 Connection of HCS-1080 E-ink Nameplate (with HCS-1080T nameplate adaptor)
  • Page 228: Operation

    3.16.4 Operation 1. Number First of all, make sure that the nameplates are connected properly to the CMU. All nameplates must be numbered when the system is used for the first time or when adding or replacing nameplates. The numbering function can be activated by nameplate system software.
  • Page 229: Chapter 4: Interpreter Unit

    Chapter 4: Interpreter unit Simultaneous interpretation function of HCS-8300 Product type: PMCS is designed for the requirements of large scale HCS-4385U/50 Interpreter unit multilingual international congresses: it can provide up Fully Digital Congress System Interpreter Unit (64 CHs, IC-Card, to 64 language channels (64 CHs). 256x64 LCD, microphone, loudspeaker) HCS-4385U/50 interpreter unit is equipped with a HCS-8385/60...
  • Page 230: Hcs-4385U/50

    4.1 HCS-4385U/50 4.1.1 Functions and indications Front Side Bottom Figure 4.1.1 HCS-4385U/50 Interpreter unit...
  • Page 231  Listening area: 10. Output channel A/B/C switch with indicating lights Loudspeaker/earphone control:  Switch to preset the output channel 1. Built-in Hi-Fi loudspeaker 11. Microphone mute key (MUTE)  When the microphones of all interpreter units in the  Push and hold the Mute button to temporarily booth disabled, listen...
  • Page 232 21. Beep button ( )  You can disable and enable the beeps of the interpreter unit with the Beep button. When beeps are enabled, the display shows a musical note. The interpreter unit can generate beeps for notification of special events to support blind interpreters on the headphones.
  • Page 233: Installation

    4.1.2 Installation HCS-4385U/50 interpreter unit is available as tabletop or e. Put the interpreter unit into the recess until the as flush-mounted version. circumferential supporting edge fits with For flush-mounting: table-top surface. Fix it with screws from the bottom. a. Make a recess in the table according to the The length of the screws depends on the thickness dimensions in figure 4.2.1;...
  • Page 234: Connection

    4.1.3 Connection 4.1.3.1 Connecting to the CMU or the EMU HCS-4385U/50 interpreter unit is equipped with a 6P-DIN cable with a standard male connector. When connecting to the CMU or the EMU, just connect the male connector of the first unit to the output of the main unit.
  • Page 235 4.1.3.3 External earphone An external earphone can be connected to the external earphone jack at the lateral side of the Interpreter unit. Its volume can be adjusted by the earphone volume control knob. The external earphone shall have a Ø 3.5 mm plug or a Ø...
  • Page 236: Setup

    4.1.4 Setup To realize the simultaneous interpretation function, the Example: interpreter unit should be incorporated in the congress Booth 1 is for translation between English/Chinese. system and they should be setup before the meeting. Output channel A is English, output channel B is Chinese, Any operating status of the interpreter unit will be and output channel C is “None”.
  • Page 237 Figure 4.1.6 Direct interpretation Figure 4.1.7 Relay interpretation Figure 4.1.8 Schematic diagram of the connection of interpreter units...
  • Page 238 4.1.4.2 LCD configuration menu When the “Interpretation setup” has been configured in Step 12: Select to display speaking time or not; the CMU, and then the interpreter unit must be Step 13: Finish. configured:  If the interpreter unit has not been configured, the Step 1: Setup operation language LCD will display “UNIT NOT INSTALLED”;...
  • Page 239 Step 4 to 8: Select monitor channel language Step 11: Select to activate the “Auto Floor” function or not Preset 5 most familiar languages as monitor channel. If the selected input language is the same as the output language and if the “Auto Floor” function is activated, the interpreter unit will switch the input channel to floor language automatically.
  • Page 240 4.1.4.3 Other configuration 4.1.4.3.1 Output channel configuration 4.1.4.3.2 Interlock mode To distribute the interpretation languages separately, Interpretation mode can be setup by menu operation A/B/C channels are provided in the interpreter unit. on the main unit (refer to section 2.1.4.2): When the interpreter unit menu configuration is finished, ...
  • Page 241: Operation

    4.1.5 Operation loudspeaker of every interpreter unit in this booth will 4.1.5.1 Number mute automatically. Now the interpreter can listen with the earphone and adjust the volume, treble and First of all, make sure that the interpreter units are bass with the “Earphone volume control knob” ⑤, connected properly to the CMU.
  • Page 242 4.1.5.3 Operation of speaking area The speaking area, on the right side of the unit, is the 8. Beeps area which is used to distribute the interpretation The audio beeps can be toggled on and off with the languages to the corresponding channels. It includes Beep button.
  • Page 243: Hcs-8385/60

    4.2 HCS-8385/60 4.2.1 Functions and indications Front Side Bottom Figure 4.2.1 HCS-8385/60 Interpreter unit...
  • Page 244 Listening area: the interpretation channel;   When the Output channel B/C switch button (B C) Loudspeaker/earphone control: was pressed, push the function knob to go to 1. Loudspeaker volume control knob channel 1, turn the function knob to select the output 2.
  • Page 245  13. Slow key (SLOW) Display:  If selected “Allow Slow” and set the requisite 17. 7.2” TFT LCD number by application software (Control – Booth  Displays unit configuration information, Manage. – Param. Setup), when the delegate is Incoming/outgoing channel number and language speaking too fast, interpreter on speaking press name, Channel number and language name of this button to remind him/her to slow down.
  • Page 246: Installation

    4.2.2 Installation HCS-8385/60 interpreter unit is available as tabletop or e. Put the interpreter unit into the recess until the as flush-mounted version. circumferential supporting edge fits with the table-top For flush-mounting: surface. Fix it with screws from the bottom. The a.
  • Page 247: Connection

    4.2.3 Connection 4.2.3.1 Connecting to the CMU or the EMU HCS-8385/60 interpreter unit is equipped with a 6P-DIN cable with a standard male connector. When connecting to the CMU or the EMU, just connect the male connector of the first unit to the output of the main unit. If there is a long distance between the congress unit and the CMU (EMU), CBL6PS extension cable can be used.
  • Page 248 Functions and indications: Left stereo channel signal Right stereo channel signal Power ground/Shield 4.2.3.4 External microphone An external headset can be connected to the TRRS jack at the lateral side of the Interpreter unit. The external headset shall have a Ø 3.5 mm plug, as in the following figure: Functions and indications: Left stereo channel signal...
  • Page 249: Setup

    4.2.4 Setup To realize the simultaneous interpretation function, the Example: interpreter unit should be incorporated in the congress Booth 1 is for translation between English/Chinese. system and they should be setup before the meeting. Output channel A is English, output channel B is Chinese, Any operating status of the interpreter unit will be and output channel C is “None”.
  • Page 250 Figure 4.2.6 Direct interpretation Figure 4.2.7 Relay interpretation Figure 4.2.8 Schematic diagram of the connection of interpreter units...
  • Page 251 4.2.4.2 LCD configuration menu When the “Interpretation setup” has been configured in the CMU, and then the interpreter unit must be configured:  If the interpreter unit has not been configured, the LCD will display “UNIT NOT INSTALLED”; In the following operation: ...
  • Page 252 QR code according to you knob, the range is limited by the configuration in phone or pad to download Taiden SI tool App. After the CMU (refer to section 2.1.4.2); installation, you can send message to all or part booths 2).
  • Page 253 4.2.4.3 Other configuration 4.2.4.3.1 Input channel configuration 4.2.4.3.3 Interlock mode The HCS-8385/60 equipped with 7 pre-select buttons Interpretation mode can be setup by menu operation (1/2/3/4/5/6/7) for relay languages with activation on the main unit (refer to section 2.1.4.2): indication on the LCD. When the monitor channel Interlock mode between booths:...
  • Page 254: Operation

    4.2.5 Operation 4.2.5.1 Operation of listening area 6. Quality indication: The second line of the display The listening area, on the left side of the unit, is the shows the qualities of the interpretations on the area used to monitor the floor or the interpretation channels that are assigned to the pre-select buttons channels.
  • Page 255 4.2.5.2 Operation of speaking area The speaking area, on the right side of the unit, is the 6. “HELP” button: If selected “Allow Help” by area which is used to distribute the interpretation application software (Control – Booth Manage. – languages to the corresponding channels.
  • Page 256: Hcs-8385Hdmi

    Figure 4.2.9: 1. HDMI output 4. SDI input 2. Mini 6P-DIN socket 5. SDI loop output  Connection to HCS-8385/60 TAIDEN new 6. Ground generation simultaneous interpreter unit through 7. Power indicator cable with mini 6pin DIN plug on each end;...
  • Page 257 HCS-8385/60 can be connected to TAIDEN High Definition Video Matrix Switcher through HCS-8385HDMI series video converter, up to 8 channels HD video signals can be transmitted to the monitors in the booths, and can easily switch among video sources via “VIDEO” button on the interpreter unit.
  • Page 258: Chapter 5 System Connection And Basic Setup Procedure

    Chapter 5 System connection and basic setup procedure 5.1 System connection HCS-4100/50 FDCS has a simple and reasonable structure with high extendibility in hardware. The system Note: installation is simple and quick and does not need  The added up cable lengths between a main special training.
  • Page 259 Table 5.1.1 Quick lookup table of HCS-4100M CMU and HCS-8300EMU load capability (each outlet) The extension cable length between the CMU(EMU) and the first Congress Unit connected to the socket Type Type No. 80 m + 80 m + HCS-4352T/50 20 m 40 m 60 m...
  • Page 260 Table 5.1.1 Quick lookup table of HCS-4100M CMU and HCS-8300EMU load capability (each outlet) - continue The extension cable length between the CMU(EMU) and the first Congress Unit connected to the socket Type Type No. 80 m + 80 m + HCS-4352T/50 20 m 40 m 60 m...
  • Page 261 Table 5.1.2 Quick lookup table of HCS-8300MES load capability (each outlet) The extension cable length between the HCS-8300MES and the first Congress Unit Type Type No. connected to the socket 20 m 40 m 60 m 80 m HCS-48U7/U8/U9/U10/ Equipped with Electronic Nameplate, speaker and microphone 4886+HCS-1080 HCS-8385/60...
  • Page 262 Table 5.1.2 Quick lookup table of HCS-8300MES load capability (each outlet) - continue The extension cable length between the HCS-8300MES and the first Congress Unit Type Type No. connected to the socket 20 m 40 m 60 m 80 m HCS-4340/50 HCS-4340DT/50 Multi-function connector...
  • Page 263: Connection Between The Cmu/Emu And The Contribution Units

    5.1.2 Connection between the CMU/EMU and the contribution units All contribution units of HCS-4100/50 system adopt Connect the 1 unit to the outlet connector of the CMU, dedicated 6-pin cable and are daisy-chained, which and following connect the plug of the cable of the 2 unit makes the installation handy and effortless.
  • Page 264: Connection Between The Cmu/Emu And Component Contribution Units

    5.1.3 Connection between the CMU/EMU and component contribution units HCS-4841/42/43 series and HCS-4341B/50 series 3. One HCS-4340HDA/50(P) multi-function connector component contribution units must be connected to the can be connected to one handheld delegate unit, one multi-function connectors with a dedicated cable. Then voting unit channel...
  • Page 265: Connection Between Hcs-4100/50 System And Automatic Video Tracking System

    5.1.4 Connection between HCS-4100/50 system and automatic video tracking system HCS-4100/50 system can be connected to an automatic compatible with several kinds of video signals and video tracking system. For video tracking purposes, the operates automatic video switching. The video tracking application software is used to make camera presets for system is composed of video switch equipment, and every congress unit.
  • Page 266: Connection Between Hcs-4100/50 System And Digital Infrared Language Distribution System

    1. First, connect the "EXTENSION" interface of the HCS-5100T/S series and digital infrared transceiver HCS-4100/50 CMU to the "EXTENSION" interface of HCS-5100R/RA series. TAIDEN digital infrared language the HCS-8300MO with a Cat. 5 cable (or connect the distribution system has 4 series: 4CHs, 8CHs, 16CHs HCS-4100/50 CMU and the HCS-8300MO with a and 32CHs.
  • Page 267 Figure 5.1.6 Congress main unit connecting to digital infrared language distribution system via HCS-5100MAF/N Figure 5.1.7 Congress main unit connecting to digital infrared language distribution system via HCS-5100MC/N...
  • Page 268: Connection Between Hcs-4100/50 System And Network Central Control System

    5.1.6 Connection between HCS-4100/50 system and network central control system TAIDEN TAIDEN network central control system is an advanced HCS-6100 network central control system and TAIDEN comprehensive control system. It can link together HCS-4100/50 system can be joined together various devices, hardware and room & media equipment seamlessly.
  • Page 269: Connection Between Hcs-4100/50 System And Conference Sign-In System

    5.1.7 Connection between HCS-4100/50 system and Conference Sign-in System The Conference Sign-in System (untouched) aims at technologies. Portrait shots and customized surface providing a reliable, effective and convenient congress design can be printed onto the RF card – combining sign-in solution for various large congresses. The system delegate's accreditation and ID in a single card.
  • Page 270: Combine/Split Congress Rooms Easily

    5.1.8 Combine/split congress rooms easily Using Cat.5 cable, several meeting rooms can be combined/separated at will through the HCS-8300MX Congress Room Combiner. One HCS-8300MX can combine up to 8 meeting rooms controlled by a Central Control System. (Several HCS-8300MX cascadable to combine additional meeting rooms). Figure 5.1.10 Combining/splitting meeting rooms with HCS-8300MX Congress Room Combiner and Cat.
  • Page 271: Total System Hot Spare

    5.1.9 Total system hot spare In the HCS-4100/50 system, the dual system main unit hot spare function cooperates with the dual PC server hot spare function, featuring multiple redundancies to realize total system hot spare function for highly enhanced system reliability. Figure 5.1.11 Dual System Main Unit Hot Spare Figure 5.1.12 Dual PC server hot spare...
  • Page 272: Basic Configuration Of A Congress System

    5.2 Basic configuration of a congress system The basic configuration is described below by a simple example. This system is composed of one HCS-4100M/50 CMU, HCS-8300ME/FS EMU, four HCS-4385U/50 interpreter units, ten HCS-4886W/50 discussion units (including chairman unit and delegate units) and several HCS-4842N/50 channel selectors (connected to the system via the HCS-4340B/50 multi-function connector).
  • Page 273 According to the requirements of the specific case in this 2. Configurate interpreter units in booth 1 (the section, the configuration is as the following: configuration of both interpreter units is the same) 1. Configuration CMU a) Channel B output: pressing output channel B switch and rotating Primary knob at the same time, and set a) Active microphone number limitation: active Chinese as channel B output language.
  • Page 274: Chapter 6 Peripheral Equipment And Accessories

    Chapter 6 Peripheral equipment and accessories 6.1 Microphone  emovable stem microphone Frequency: Functions and instructions:  M-style Foam Windshield 1. Electret condenser cardioid microphone 2. Two-color microphone on/off LED ring Indicating light Work state of LED ring Microphone On Red (on) Speaking time limit Red (on)
  • Page 275  HCS-1020 clip microphone...
  • Page 276: Earphones

    6.2 Earphones The jack plug of the stereo headphone can be inserted EP-960AH Interpreter headset  into a Ø 3.5 mm stereo headphone jack socket. Applicable types include: EP-820AS Single earphone  EP-960BH Interpreter headphone  EP-829 Single earphone  EP-960HD Detachable Earshells ...
  • Page 277: Accessories

    6.3 Accessories Some dedicated accessories are involved in the connection of conference system devices. Herein, these accessories are introduced, including:  CBL6PS 6-pin dedicated extension cable  CBL6PS-CMP 6-pin dedicated extension cable  CBL6PP-02 dedicated 6-pin extension cable  CBL6PP-02CMP dedicated 6-pin extension 4.
  • Page 278  h × w × d: 43 × 66 × 67 mm 7. CBL-XLR2DIN-01 XLR to DIN Converting Cable  Used for external strong signal accessing to TAIDEN conference system  XLR connector for external audio source input  6P mini DIN connector for connection to the...
  • Page 279: Chapter 7 Working Environment And Maintenance

    The covers should only be removed attention to: by qualified service personnel. If any repair or  Terminating and maintenance of optical fiber maintenance is required, contact the TAIDEN should be carried out by strictly trained technical service center in your region.  staff;...
  • Page 280: System Operator Room

     In the hall, booths should be set up at the back or sideways.  Booths should be elevated to provide an overall, unobstructed direct view of the chairman, the speakers and any other relevant visual aids.  A window should be installed at the forefront of the booth across the overall length.
  • Page 281: Chapter 8 Technical Specifications

    Chapter 8 Technical specifications 8.1 System specifications System performance Conforms to IEC 60914, the international standard for congress systems System environmental conditions Working conditions fixed/stationary/transportable Temperature range: - Transport: -40 °C to +70 °C - Operating: 0 °C to +45 °C Max.
  • Page 282: Congress System Main Unit

    8.2 Congress system main unit 8.2.1 Congress main unit Physical characteristics 8.2.1.1 HCS-4100MA/50 Types HCS-4100MB/50 HCS-4100MC/50 HCS-4100MA/FS/50 Installation Tabletop / standard 19-inch rackmount Dimensions (mm) Color White (PANTONE 420 C) Weight 7.8 kg 8.2.1.2 Electrical characteristics HCS-4100MA/50 Types HCS-4100MB/50 HCS-4100MC/50 HCS-4100MA/FS/50 ≤4096...
  • Page 283: Extension Main Unit

    8.2.2 Extension main unit 8.2.2.1 Physical characteristics Types HCS-8300ME(/FS) Installation Tabletop / standard 19-inch rackmount Dimensions (mm) Color White (PANTONE 420 C) Weight 10.0 kg 8.2.2.2 Electrical characteristics Types HCS-8300ME(/FS) America, Japan: AC 100 V - 120 V 60 Hz Mains power supply Europe, Asia: AC 220 V - 240 V AC 50 Hz >1 kΩ...
  • Page 284: Congress Unit

    8.3 Congress unit 8.3.1 HCS-48U6 series congress unit 8.3.1.1 Physical characteristics Types HCS-48U6 Installation Flush-mounted Dimensions (mm)
  • Page 285 Color Black (PANTONE 419 C) 0.35 kg (HCS-48U6MICM HCS-48U6SELM) 0.08 (HCS-48U6MICS HCS-48U6DVOT) Weight 0.18 kg (HCS-48U6SPK) 8.3.1.2 Electrical characteristics Types HCS-48U6 Output frequency 30 - 20000 Hz response >16 Ω Earphone load Earphone volume 10 mW Earphone output Ø 3.5 mm stereo jack Max.
  • Page 286: Hcs-48U7/U8/U9 Series Congress Unit

    8.3.2 HCS-48U7/U8/U9 series congress unit 8.3.2.1 Physical characteristics Types HCS-48U7/U8/U9 Installation Flush-mounted Dimensions (mm)
  • Page 287 Color Black (PANTONE 419 C) 0.6 kg (HCS-48U7MICSPK) Weight 1.0 kg (HCS-48U7/U8) 0.9kg (HCS-48U9) 8.3.2.2 Electrical characteristics Types HCS-48U7/U8/U9 Output frequency 30 - 20000 Hz response >16 Ω Earphone load Earphone volume 10 mW Ø 3.5 mm stereo jack Earphone output 2.3 W (with 256×32 LCD) Max.
  • Page 288: Hcs-48U10 Series Congress Unit

    8.3.3 HCS-48U10 series congress unit 8.3.3.1 Physical Characteristics Types HCS-48U10 Installation Flush-mounted Dimensions (mm) Note: the height for HCS-48U10DDS and HCS-48U10DS is 51 mm. Color Black (PANTONE 419 C) Weight 0.82 kg 8.3.3.2 Electrical Characteristics Types HCS-48U10 Output frequency 30 - 20000 Hz response >16 Ω...
  • Page 289: Hcs-4886/87/88 Series Congress Unit

    8.3.4 HCS-4886/87/88 series congress unit 8.3.4.1 Physical characteristics Types HCS-4886/87/88 Installation Tabletop Dimensions (mm) Champagne (PANTONE 401) panel + grey (PANTONE 424 C) base / black HCS-4886/87/88/50 (PANTONE 419 C) base Note: only champagne panel + grey base for HCS-4886NX/50 operator unit Color Champagne (PANTONE 401) panel / Charcoal gray (PANTONE Cool Gray 11 HCS-4886/87/88/52...
  • Page 290: Hcs-4380/82/70/71 Series Congress Unit

    8.3.5 HCS-4380/82/70/71 series congress unit 8.3.5.1 Physical Characteristics Types HCS-4370/71/80/82 /50 Installation Tabletop/Flush-mounted Dimensions (mm) Color Charcoal gray (PANTONE Cool Gray 11 C) Weight 1.7 kg 8.3.5.2 Electrical Characteristics Types HCS-4370/71/80/82 /50 Output frequency 30 - 20000 Hz response >16 Ω Earphone load Earphone volume 10 mW...
  • Page 291: Hcs-4360/61/62/63 Series Congress Unit

    8.3.6 HCS-4360/61/62/63 series congress unit 8.3.6.1 Physical Characteristics Types HCS-4360/61/62/63 /50 Installation Flush-mounted Dimensions (mm) Color Charcoal gray (PANTONE Cool Gray 11 C) Weight 0.7 kg 8.3.6.2 Electrical Characteristics Types HCS-4360/61/62/63 /50 Output frequency 30 - 20000 Hz response >16 Ω Earphone load Earphone volume 10 mW...
  • Page 292: Hcs-4338N/50 Series Congress Unit

    8.3.7 HCS-4338N/50 series congress unit 8.3.7.1 Physical Characteristics Types HCS-4338N/50 Installation Tabletop Dimensions (mm) Champagne (PANTONE 401 C) panel Color Charcoal gray (PANTONE Cool Gray 11 C) panel Weight 1.0 kg 8.3.7.2 Electrical Characteristics Types HCS-4338N/50 Output frequency 30 - 20000 Hz response >16 Ω...
  • Page 293: Hcs-4860/4865/4866 Series Congress Unit

    8.3.8 HCS-4860/4865/4866 series congress unit 8.3.8.1 Physical Characteristics Types HCS-4860/4865/4866 Installation Tabletop The length of microphone of HCS-4860/50/2M is 194 mm. Note: the HCS-4866/50 series equipped with fixed gooseneck microphone, length:41 cm, others are the same with the HCS-4865 series Black (PANTONE 419 C) Color HCS-4860/50...
  • Page 294 8.3.8.2 Electrical Characteristics Types HCS-4860/4865/4866 Output frequency 30 - 20000 Hz response >16 Ω Earphone load Earphone volume 10 mW Earphone output Ø 3.5 mm stereo jack Max. power 1.8 W consumption Connection 6P-DIN dedicated cable with buckle Microphone parameters of HCS-4860/4865 Type Supercardioid uni-directional electret condenser microphone Sensitivity...
  • Page 295: Hcs-4851/50 Series Congress Unit

    8.3.9 HCS-4851/50 series congress unit 8.3.9.1 Physical Characteristics Types HCS-4851/50 Installation Flush-mounted Dimensions (mm) Note:  Array microphone length: 200 mm, inclined angle up to 30° Black (PANTONE 419 C) Color Champagne (PANTONE 401) Weight 1.7 kg 8.3.9.2 Electrical Characteristics Types HCS-4851/50 Output frequency...
  • Page 296: Hcs-4330/31/32/33/35 Series Congress Unit

    8.3.10 HCS-4330/31/32/33/35 series congress unit 8.3.10.1 HCS-4330/32 /50 series congress unit 1. Physical Characteristics Types HCS-4330/32 /50 Tabletop Installation Dimensions (mm) Gray/Silver Color Weight 0.74 kg 2. Electrical Characteristics Types HCS-4330/32 /50 Output frequency 30 ~ 20000 Hz response >16 Ω Earphone load Earphone volume 10 mW...
  • Page 297 8.3.10.2 HCS-4331/33/35 /50 series congress unit 1. Physical Characteristics Types HCS-4331/33/35 /50 Installation Tabletop Dimensions (mm) Color Gray/Silver Weight 0.74 kg 2. Electrical Characteristics Types HCS-4331/33/35 /50 Output frequency 30 ~ 20000 Hz response >16 Ω Earphone load Earphone volume 10 mW Earphone output Ø...
  • Page 298: Hcs-4325/26/27 Series Congress Unit

    8.3.11 HCS-4325/26/27 series congress unit 8.3.11.1 Physical Characteristics Types HCS-4325/26/27 /50 Installation Flush-mounted Dimensions (mm) Handheld microphone with 0.9 meters spring cable can be stretched to 2 meters. HCS-4325/50 Charcoal gray (PANTONE Cool Gray 11 C) HCS-4326/50 Silver (PANTONE 428 C) Color HCS-4327/50 Black (PANTONE 419 C)
  • Page 299 8.3.11.2 Electrical Characteristics Types HCS-4325/26/27 /50 Output frequency 30 - 20000 Hz response >16 Ω Earphone load Earphone volume 10 mW Earphone output Ø 3.5 mm stereo jack Max. power 1.3 W consumption Connection 6P-DIN dedicated cable with buckle Uni-directional electret condenser microphone Type Sensitivity -46 dBV/Pa...
  • Page 300: Hcs-4341/50 Series Congress Unit

    8.3.12 HCS-4341/50 series congress unit 8.3.12.1. Physical Characteristics Types HCS-4341B/50 HCS-4341HD/50 Installation Tabletop Flush-mounted Dimensions (mm) Color Black (PANTONE 419 C) 80 g 0.1 kg Weight 8.3.12.2. Electrical Characteristics Types HCS-4341B/50 HCS-4341HD/50 Output frequency 30 - 20000 Hz response Cat.5 cable with standard RJ45 plug, Connection Cable with 6P mini DIN plug connecting to multi-function connector...
  • Page 301: Hcs-4340/50 Series Multi-Function Connector

    8.3.13 HCS-4340/50 series multi-function connector 8.3.13.1. Physical Characteristics Types HCS-4340/50 Installation Fixed installation Dimensions (mm) Color Charcoal gray (PANTONE Cool Gray 11 C) 0.9 kg Weight 8.3.13.2. Electrical Characteristics Types HCS-4340CA/50 HCS-4340DA/50 HCS-4340HDA/50(P) HCS-4340B/50 HCS-4340DT/50 1 handheld delegate 1 chairman 1 delegate discussion unit + 1 2 delegate...
  • Page 302: Hcs-4841/42/43 Series Congress Unit

    8.3.14 HCS-4841/42/43 series congress unit 8.3.14.1 Physical Characteristics Types HCS-4841/42/43 Installation Flush-mounted Dimensions(mm)
  • Page 303 HCS-4841N/50 Charcoal gray (PANTONE Cool Gray 11 C) HCS-4842N/50 Silver (PANTONE 428 C) HCS-4843N/50 Color Silver (PANTONE 428 C) HCS-4842NA/50 Black (PANTONE 419 C) HCS-4841U/50 Black (PANTONE 419 C) HCS-4841UA/50 HCS-4841N/50 0.2 kg (incl. stem microphone) HCS-4841U/50 0.2kg (incl. stem microphone) HCS-4841UA/50 0.2kg (incl.
  • Page 304 8.3.14.2 Electrical Characteristics HCS-4841N/50 HCS-4842N/50 Types HCS-4841U/50 HCS-4843N/50 HCS-4842NA/50 HCS-4841UA/50 Output frequency response 30 - 20000 Hz >16 Ω Earphone load Earphone volume 10 mW Ø 3.5 mm stereo Earphone output jack Connection Cat.5 cable with standard RJ45 plug, connecting to multi-function connector Type Uni-directional electret condenser microphone Sensitivity...
  • Page 305: Hcs-4368/50 Series Wired Voting Unit

    8.3.15 HCS-4368/50 series wired voting unit 8.3.15.1 Physical Characteristics Types HCS-4368/FM/50 HCS-4368/50 Installation Flush-mounted Tabletop Dimensions (mm) Silver (PANTONE 428 C) Red (PANTONE 476 C) Color Red (PANTONE 476 C) Weight 0.6 kg 0.5 kg 8.3.15.2 Electrical Characteristics Type HCS-4368/50 Max.
  • Page 306: Hcs-1080 Series Electronic Nameplate

    8.3.16 HCS-1080 series electronic nameplate 8.3.16.1 Physical Characteristics Types HCS-1080 Installation HCS-1080 Tabletop fixed installation Dimensions (mm) Color Black (PANTONE 419 C) HCS-1080 1.2kg Weight HCS-1080T 0.5 kg 8.3.16.2 Electrical Characteristics Types HCS-1080 HCS-1080T Display dimensions 310 mm x 60 mm Resolution 1200 x 232 2.1 W...
  • Page 307: Interpreter Unit

    8.4 Interpreter unit 8.4.1 HCS-4385U/50 Physical characteristics 8.4.1.1 Type HCS-4385U/50 Installation Tabletop Dimensions (mm) Color Champagne (PANTONE 401 C) Weight 0.9 kg Electrical characteristics 8.4.1.2 Type HCS-4385U/50 Output frequency 30 - 20000 Hz response >16 Ω Earphone load Earphone volume 10 mW Earphone output Ø...
  • Page 308: Hcs-8385/60

    8.4.2 HCS-8385/60 8.4.2.1 Physical characteristics Type HCS-8385/60 Installation Tabletop Dimensions (mm) Color Champagne (PANTONE 401 C) 1.1 kg Weight Electrical characteristics 8.4.2.2 Output frequency response HCS-8385/60 30 - 20000 Hz Earphone load >16 Ω Earphone volume Earphone output Audio level is adjusted automatically according to impedance Ø...
  • Page 309: Hcs-8385Hdmi

    8.4.3 HCS-8385HDMI 8.4.3.1 Physical characteristics Type HCS-8385HDMI Installation Tabletop Dimensions (mm) Color Gray (PANTONE 425 C) Weight 0.4 kg 8.4.3.2 Electrical characteristics Type HCS-8385HDMI Signal type Connector Video 720p50,720p60 input Resolutions 1080i50,1080i60 1080p25,1080p30,1080p50,1080p60 Signal type HDMI Video Connectors 2 × female HDMI type A connectorI output Resolutions Up to 1080p60...
  • Page 310: Peripheral Equipment And Accessories

    8.5 Peripheral equipment and accessories 8.5.1 Pluggable stem microphone 8.5.1.1 Physical Characteristics Types MS24EMF1G/S MS33EMF1G/S/B MS41EMF1G/S/B MS47EMF1G/S/B Installation Insert microphone and tighten Length 240mm 330 mm 410 mm 470 mm Silver (PANTONE 428 C) / Gray (PANTONE Cool Gray 11 C) / Black (PANTONE 419 C) Color Weight 75 g...
  • Page 311: Earphone

    8.5.2 Earphone   EP-820AS single earphone Frequency response of headphone: 20 Hz to 20  Cooperates with the infrared receiver or the Sensitivity of headphone: ≥108 dBA/1 mW  congress unit  Polar pattern of microphone: Omnidirectional  Hi-Fi sound quality ...
  • Page 312  EP-960HD Detachable Earshells  Used for EP-960AH and EP-960BH  Earshell detachable washable, convenient for cleaning  Color: black  HCS-5100PA headphone  Cooperates with the infrared receiver or the congress unit  Hi-Fi sound quality 32 Ω×2, Ø 3.5 mm stereo jack ...
  • Page 313: Accessories

    Length: 1-meter (only for CBL6PS), 3-meter,  Used for external strong signal accessing to 5-meter, 10-meter, 20-meter, 30-meter, TAIDEN conference system 40-meter and 50-meter  XLR connector for external audio source input  6P mini DIN connector for connection to the ...
  • Page 314: System Connection

    8.6 System connection 8.6.1 Mains cables Blue Neutral Brown Hot (Phase) Green/Yellow Earth/Ground 8.6.2 Audio cables 3-pole XLR connector (female) Pin 1 Earth Pin 2 Signal + Pin 3 Signal - Chinch connector (male) Pin 1 Signal + Pin 2 GND 8.6.3 Earphone 3.5 mm Jack plug Tip (1) Signal left...
  • Page 315: Display Language List

    8.7 Display language list № № № Chinese English Abbr. Chinese English Abbr. Chinese English Abbr. 原声 孟加拉国语 夏威夷语 Floor Bengali Hawaiian 阿尔巴尼亚 缅甸语 坎那达语 Albanian Myanmar Kannada 阿拉伯语 白俄罗斯语 克什米尔语 Arabic Belarusian Kashmiri 保加利亚语 科西嘉语 Bulgarian Corsican Central 加泰罗利亚 爱尔兰语...
  • Page 316: Appendix:custom-Made Cable

    Appendix:Custom-made cable AppendixⅠ: Dedicated 6 PIN Extension Cable...
  • Page 317 TAIDEN INDUSTRIAL CO., LTD. 6/F, Block B, Future Plaza, 6060 Qiaoxiang Rd, Nanshan District, Shenzhen, China P.C.: 518053 Copyright by TAIDEN Website: http://www.taiden.com Last Revision: 01/2017...

This manual is also suitable for:

Hcs-4100ma/fs/50Hcs-4100mb/50Hcs-4100mc/50

Table of Contents