Taiden HCS-4800 Series Installation And Operating Manual

Taiden HCS-4800 Series Installation And Operating Manual

Fully digital congress system
Hide thumbs Also See for HCS-4800 Series:
Table of Contents

Advertisement

HCS-4800 Series Fully Digital Congress System
Fully Digital Congress System
Installation and Operating Manual
V 1.0.1

Advertisement

Table of Contents
loading

Summary of Contents for Taiden HCS-4800 Series

  • Page 1 HCS-4800 Series Fully Digital Congress System Fully Digital Congress System Installation and Operating Manual V 1.0.1...
  • Page 2  To protect your hearing, avoid high pressure level on earphones. Adjust to a lower and convenient level. If any detailed information is needed, please contact your local agent or TAIDEN service center in your region.  Any feedback, advice and suggestion about the products is appreciated TAIDEN is the registered trademark of TAIDEN Co.
  • Page 3 The MAINS plug serving as a disconnection device, Service Center. 20. All TAIDEN products are guaranteed for definite time should be easy to operate. The apparatus should be connected to the MAINS (see the WARRANTY CARD for details) excluding the following cases: socket-outlet with protective earth.
  • Page 4 Important Safety Instructions The exclamation mark within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance (servicing) instructions in the literature accompanying the appliance. WARNING: To reduce the risk of fire or electric shock, DO NOT expose units to rain or moisture.
  • Page 5: Table Of Contents

    Contents Chapter 1: Introduction ..............................1 1.1 Summary ................................1 1.2 System technology ..............................2 1.3 Functions ................................5 1.4 Features ................................. 7 Chapter 2 Congress main unit (CMU) ........................... 9 2.1 Fully Digital Congress System Main Unit ......................12 2.1.1 Functions and instructions ........................
  • Page 6 3.8.3 Operation ............................... 128 3.9 HCS-4840DHT & HCS-4842DHT ........................131 3.9.1 Functions and indications........................131 3.9.2 Installation ............................. 132 3.9.3 Connection ............................. 132 3.9.4 Operation ............................... 134 3.10 HCS-4841DMIC Multifunction Connector ....................135 3.10.1 Functions and indications ..........................135 3.12 HCS-4856 Lift Microphone ..........................138 3.12.1 Function and indications ..........................
  • Page 7 8.2.3 Congress extension main unit ........................ 168 8.3.2 HCS-4890N/80 series congress unit ...................... 169 8.3.3 HCS-4890N/80 series congress unit ...................... 170 8.3.4 HCS-4838 series congress unit ......................171 8.3.5 HCS-48U6/80 series congress unit ......................173 8.3.6 HCS-48U7/U8/U9 series congress unit ....................175 8.3.7 HCS-48U10/50 series congress unit ......................
  • Page 8 (EMU). Chapter 3:Congress unit Detailed descriptions of the functions and indications, installation and connection, configuration and operation of the HCS-4800 series discussion units and the voting units. Chapter 4:Interpreter unit Detailed descriptions of the functions and indications, installation and connection, configuration and operation of the HCS-8685 interpreter unit.
  • Page 9 Installation & User Guide This manual is applicable to: discussion, voting, 64 CHs×2, 4.3" touch screen, black) HCS-4891DVS_B/80  Congress main units Fully Digital Congress System Delegate Unit (tabletop, discussion, HCS-4800MA voting, 64 CHs×2, 4.3" touch screen, black) Fully Digital Congress System Main Unit (discussion, voting, 64 HCS-4891C_B/80 CHs, single-mode optical fiber interface) Fully Digital Congress System Chairman Unit (tabletop,...
  • Page 10 HCS-4891RD_S/80/2M HCS-48U6DMICS Fully Digital Congress System Delegate Unit (tabletop, discussion, Fully Digital Congress System Delegate Unit (flush-mounting, 4.3" touch screen, rectangular columnar metal microphone, main discussion, HCS-48U6SELM/80 needed , black) microphone + backup microphone, silver microphone + black HCS-48U6SELM/80 base) Fully Digital Congress System Delegate Unit (flush-mounting, discussion, HCS-48U6SELM/80 needed, black) HCS-4838 series congress units...
  • Page 11 1 chairman unit + 1 loudspeaker, black) Fully Digital Congress System Chairman Unit (tabletop, HCS-4840DU/80 discussion, rectangular columnar metal microphone, 64 CHs, Multi-function Connector (for HCS-48U7 series, for connection to OLED, black) HCS-4860DS_B /80 1 delegate unit + 1 loudspeaker, black) Fully Digital Congress System Delegate Unit (tabletop, discussion, rectangular columnar metal microphone, 64 CHs, OLED, black) HCS-48U8/80 series congress units:...
  • Page 12 HCS-4840DHT Nameplate management system or Nameplate server needed, Multi-function Connector (for connection black) HCS-4842DHT channel selectors, silver) HCS-1082SN_W HCS-4842DHT E-ink Electronic Nameplate (tabletop, single screen, 14.74”, 64-Channel Selector (flush-mounting, HCS-4840DHT needed, microphone status indicator, USB connector to HCS-86** series black) multimedia congress terminal, RJ45 connector supports PoE, HCS-4841DMIC Nameplate management system or Nameplate server needed,...
  • Page 14: Chapter 1: Introduction

    HCS-4800 Fully Digital Congress System consists of network techniques. Furthermore, with perfect congress main unit, contribution units and application integration of TAIDEN Conference Sign-in System and software. Congress main unit includes the congress Central Control System, HCS-4800 takes control main unit (CMU) and the extension main unit leadership in providing comprehensive and efficient (EMU).
  • Page 15: System Technology

    HCS-4800 is competent for the infrastructure. management of various meetings via several basic By virtue of using the MCA-STREAM technology, conference management facilities, such as basic HCS-4800 Series Fully Digital Congress System microphone management, electronic voting, carries out: multilingual simultaneous interpretation, etc.
  • Page 16 HCS-4800 is applicable to any kind consider connection reliability as their leading point, of conference and provides an accurate and efficient HCS-4800 Series Fully Digital Congress System solution. Additional congress units can be added when adopts advanced "Closed Loop - Daisy Chain"...
  • Page 17 HCS-8600 and HCS-4800 series congress units, congress units are connected together in a daisy chain convenient for wiring and installation. configuration and connected to the main unit by the All congress units of HCS-8600 and HCS-4800 series dedicated extension cable.
  • Page 18: Functions

    PC. The result is displayed on the LCD  VIP unit configurable: of every contribution unit  By using TAIDEN conference management  Dedicated software for more forms of voting: system software  For/Against  VIP unit can be activated in any mode freely, ...
  • Page 19  Multilingual (simplified/traditional Chinese and Sign-in System and the Central Control English, etc.) menu System  Contribution units equipped with graphic 256x32 The seamless integration of HCS-4800 Series Fully LCD show: Digital Congress System, TAIDEN conference sign-in  English menu system...
  • Page 20: Features

     System operability System reliability, as described below, has always been CMU controls efficiently: basic microphone control, the guiding principle while designing HCS-4800 series simultaneous interpretation, video tracking, voting - fully digital conference system: without the intervention of an operator.
  • Page 21  System maintenance TAIDEN application software provides testing functions for online testing the operating conditions such as validity of the keys, LCD and microphones. A detailed test report is issued for quick and simple maintenance of the system device.
  • Page 22: Chapter 2 Congress Main Unit (Cmu)

    Chapter 2 Congress main unit (CMU) The congress main unit (CMU) forms the core of the HCS-4800 Series Paperless Multimedia Congress System. It provides power supply to contribution units and serves as the key component for linking up hardware with application software. In stand-alone mode without a PC, the CMU carries out basic management facilities;...
  • Page 23: Fully Digital Congress System Main Unit

    2.1 Fully Digital Congress System Main Unit 2.1.1 Functions and instructions Front panel of HCS-4800M CMU Backside of HCS-4800MA CMU Backside of HCS-4800MB CMU Backside of HCS-4800MC CMU...
  • Page 24 Backside of HCS-4800MA/20 CMU Backside of HCS-4800MB/20 CMU Backside of HCS-4800MC/20 CMU Figure 2.1.1 HCS-4800M series congress main unit Figure 2.1.1 1. “STANDBY” button with indicator button) to select the red highlighted item or enter a. Switches to red in standby mode; the next menu;...
  • Page 25 6. Fiber interface  Single-mode optical fiber, SC connector;  Connecting the conference main units of several distant conference rooms to combine as one conference room (bridging distance can reach tens of kilometers). 7. Contribution units (CU) connection LED  When output works properly (≥ 1 CU connected), LED will flash;...
  • Page 26: Connection

    2.1.2 Connection 2.1.2.1 To contribution units HCS-4800 series CMU has 2 outlet (8P-DIN) trunk-line cable sockets for connecting to contribution units. TAIDEN full digital congress unit has two types of connection interface, a) equipped with two cables with standard 8P-DIN connectors; or b) equipped with two...
  • Page 27 CMU/EMU, a Cat5e cable can be used. One end of topology (RJ45) the Cat5e cable is connected to output of the main unit In HCS-4800 series fully digital congress system, via the CBL8P2RJ45S converter cable; the other end power is provided by HCS-4800M CMU (or HCS-8600 of the Cat5e cable is connected to the contribution unit.
  • Page 28 The HCS-4800MB fully digital congress system main unit builds in power amplifier and has 2 Speakon audio output interfaces, which can be directly connected to the loudspeaker. It is suitable for small conference rooms and simplifies system configuration. As shown in Figure 2.1.9.
  • Page 29: Configuration And Operation

    2.1.3 Configuration and operation After installation and connection and prior to the hereinafter means the information displayed on the meeting, the CMU should be configured through the LCD as the “user” interface. dialog menu and button. The term “interface” used The menu structure is shown in the following figure: Figure 2.1.10 LCD menu structure of the CMU A) Starting initialization...
  • Page 30 Max. Active Mics active unit gets off. “Override”: Set the maximal number of microphones that can be turned on at the same time: 1~8. If the maximal number (1~8) of active delegate microphones has been reached and if another delegate unit is activated, the delegate unit switched on first will be switched off first automatically (first in / first out).
  • Page 31 a). Rotate the function knob to select the sub menu; b). Press the function knob to enter audio mode setting interface; c). Rotate function knob to select audio mode; d). Press the function knob to save and return to upper level menu.
  • Page 32 interlock modes; If ALL is selected for C then  “INTERLOCK” mode prevents that two booths step: select a language for B. Three channels are engage the same channel. now available: A and B output a selected language and  “OVERRIDE”...
  • Page 33 3). If ALL is selected for C then quantity and press function knob to go to the next rotate function knob to select language for B from step; those languages that have been selected in step b) and press function knob to confirm; 3).
  • Page 34 d). Press the function knob to set time (at this time, the time item number bold display); e). Rotate the function knob to adjust the value; f). Press the function knob to save the value; g). Repeat steps c)~f) and set the other time items in turn;...
  • Page 35 C). DHCP Same chronological order as for “IP Address” set up. h). Select “IP Address” and press the function knob to go to setup IP address interface; a). Select “DHCP” and press the function knob to go to i). Rotate function knob to switch between the four setup DHCP interface;...
  • Page 36 11. Alarm Setting Note:  When controlled by PC software, “Subnet Mask” and “Gateway” should be setup according to the PC configuration, otherwise it may cause a connection problem. Rotate the function knob to select “Disable” or 9. Language setting “Enable”...
  • Page 37 “STANDBY” button or not; Press function knob to exit LED test interface. b). Rotate function knob to select “Enable” or 13.About “Disable”;  If “Enable” is selected, power on through the information includes: firmware version, corporation information and series number, shown as “POWER”...
  • Page 38: Web Control

    2.1.5 Web Control HCS-4800M series of congress main unit build in web control functions, can be viewed and controlled by any computer via input IP address in the browser. Including MU State, Parameters, Audio Output, Unit Setup, Video Matrix, Predefine Position, Microphone Control, Assets Management, System Test, Main Unit Translation and Unit Upgrade.
  • Page 39  Active Microphones: set the maximum number of active microphones: 1~8 optional. If the active number reaches the limit, other delegate microphones cannot be activated, while the chairman and VIP unit(s) can be activated at any time (the setup only affects the delegate units). Whatever may be the operation mode, the maximum number of active microphones cannot exceed eight.
  • Page 40 Main Unit Parameters:  Disconnect PC and allow chairman to control Request: when PC disconnected, chairman unit can approve/overrule delegates request;  Use Extension Port: select whether use extension port or not;  Use Fiber Port: select whether use fiber port or not; ...
  • Page 41  Audio Input Based on TAIDEN originated CongressMatrix technology, supports 2 audio line in + 2 USB in, or 1 audio line in + 1 microphone input + 2 USB in, gain and EQ for each input adjustable separately. +48 V phantom power supply at microphone input, condenser microphone can be connected directly.
  • Page 42 USB In 1~2: set Gain (range: -30 dB ~0 dB) and EQ (5 band, range: -15 dB ~15 dB), display real-time level;  Audio Output Based on TAIDEN CongressMatrix technology, supports 26 audio outputs. Line Out 1~2: 31 band graphical EQ + Limiter +Delay, the maximum delay time is 1000 ms;...
  • Page 43 Audio mode - Teleconference Mode: the input source Line In 1 cannot be output through Line Out1 and can be output normally through other output channels, as shown in the following figure: Line In 1 cannot be output through Line/AES Out1 All inputs can be output through Line Out 2, USB 1~2 Audio mode - External Processor Mode: Line In 1 input source can be output through down-stream audio channel, other input sources can be output normally through output channels, as shown in the following figure:...
  • Page 44 ♦ 31 band GEQ: Line Out 1~2 support the 31 band graphical equalizer; Narrow Band Normal Wide Band ♦ 8 band PEQ: USB Out 1~2 support the 8 band parametric equalizer; ♦ Limiter: double click it to open setting interface; Bypass: disabled limiter;...
  • Page 45 Enable limiter Disable limiter ♦ Delay : double click it to set delay time, the maximum is 1000 ms; ♦ Line Out 1~2, USB Out 1~6: double click it to set output gain; Note: the HCS-4800 system cannot choose the audio matrix software; the HCS-8600 system can choose the audio matrix software according to the need.
  • Page 46 Normal and Teleconferencing mode: Enable/Disable the left channel to the downstream audio. External Processor mode: Only line in 1 can be output to the . downstream audio Figure: Down Stream Setup  Scene Setting: Input, Mixer, EQ, Limiter, Delay, Output parameters and downstream audio parameters can be saved as a scene, and then can be called next time.
  • Page 47 Figure: Audio Output Parameters Setup Unit Setup Figure: Unit Setup  Unit Parameters: is to set up facilities for each conference contribution unit. The facilities include different Degrees (Delegate, VIP, and Audience), Functions (Speaking, Vote, and IC Card), and Phantom Power (On/Off) for multi-function connector HCS-4340A/50P;...
  • Page 48  Ambient Mic.: set up one contribution unit as ambient microphone (used to pick up ambient sound in the congress room), if any other contribution unit microphone turns on, the ambient microphone will turn off automatically; otherwise, the ambient microphone keeps activated. Check " "...
  • Page 49 Predefine Position Figure: Predefined Position Panorama setup: select proper matrix, camera and predefine position number, then adjust the camera angle by the four direction buttons, and click zoom in/out button to adjust the size of the video image, at last, click “Save and Send to MU” button to save the panorama if the adjustment is done.
  • Page 50 Microphone Control Click the microphone to open preset interface Back to panoramic position Figure: Microphone control Click the “Mic. Control” to enter the interface. The function icons are: / : turn on/turn off : flash/close flash : track this unit : add to request list : approve/reject request : move up/down...
  • Page 51 System Teat TAIDEN conference system provides the facility for system testing to find out the problems of units accurately. This facility aims to find out and solve the problems prior to a conference to ensure the reliability of the entire conference system.
  • Page 52 Figure: Key Test interface  Mic. Test Test the microphone of the units connected to the conference main unit, and the interface of the following figure is displayed: To begin the test, the user shall first set the test time for each microphone in “Mic. Test Time (00:00:00, HH:MM:SS)”, select “Play Sound”...
  • Page 53  SI Channel Test When SI channel test started, HCS-8685 will play the monitor channel name, and if the channel is not defined in the system, the sound “Floor” will be played. Figure: SI Channel Test interface  LED Test Press the “Start Test”...
  • Page 54 Main Unit Translation Chinese and English are default language for main unit, if other language needed, language item can be translated here one by one, save the language, at last, compile and upload the new language items to the main unit. Select target language Figure: Main Unit Translation Unit Upgrade...
  • Page 55 Menu operation Congress Main Unit:  Select "About" menu;  Turn function knob left to enter Update DCS Units interface;  Turn function knob to select Yes; Click "Start Upgrading"; Reboot main unit after upgrading.
  • Page 56: Extension Main Unit

    2.2 Extension Main Unit 2.2.1 Functions and instructions Front panel Backside of HCS-8600MEA2 Backside of HCS-8600MEA Figure 2.2.1 HCS-8600MEA series extension main unit Figure 2.2.1: 1. Overload indicator and restart button 7. Contribution unit outlet 6P-DIN (1-5)  Normal: turn off; 8.
  • Page 57: Connection

    2.2.2 Connection HCS-4800M series CMU has two 8P-DIN output Each extension main unit has an extension input port interfaces; the power capacity of each 8P-DIN interface for connecting to extension interface of the congress is limited. If the actually needed power of the system main unit, another...
  • Page 58: Extension Unit

    2.3 Extension Unit 2.3.1 Functions and instructions Figure 2.3.1 HCS-8600 series extension unit Figure 2.3.1: 1. Power input 2. Power light (Red) 3. Extension input  Connecting to CMU or last HCS-8600MES. 4. Extension input indicator 5. Extension output  Connecting to next HCS-8600MES. 6.
  • Page 59: Installation

    2.3.2 Installation The extension unit can be fixed on flat surface (table, wall, ground, etc). Make holes on flat surface according to the following figure, then fixed extension unit with M3 screws. Figure 2.3.2 Installation of the HCS-8600MES The HCS-8600MES extension unit can also be installed on a standard 19-inch cabinet with a HCS-MES-RCF cabinet mounting bracket.
  • Page 60: Chapter 3: Congress Units

    HCS-4890NDVSE/FM_B/80 network techniques. Furthermore, with perfect Fully Digital Congress System Delegate Unit (flush-mounting, integration of TAIDEN Conference Sign-in System and discussion, 5 voting keys, built-in contactless IC-Card slot, 64 Central Control System, HCS-4800 takes CHs, 4.3" touch screen, black) leadership in providing comprehensive and efficient digital conference system solutions.
  • Page 61 HCS-48U6/80 series congress units microphone, silver microphone + black base) HCS-4891RDVS_S/80/2M HCS-48U6CMICM/80 Fully Digital Congress System Delegate Unit (tabletop, discussion, Fully Digital Congress System Chairman Unit (flush-mounting, voting, 64 CHs×2, 4.3" touch screen, rectangular columnar metal discussion, HCS-48U6VOT HCS-48U6SPK microphone, main microphone + backup microphone, silver connected, black) microphone + black base) HCS-48U6DMICM/80...
  • Page 62 HCS-48U10DVE/80 Flush-mounting Loudspeaker Panel (HCS-48U7VOTF/80 or HCS-48U7U/80 needed, black) Fully Digital Congress System Delegate Unit (flush-mounting, HCS-48U7CM/80 discussion, 3 voting keys, built-in contactless IC-Card slot, black) Fully Digital Congress System Chairman Unit (flush-mounting, HCS-48U10DS/80 discussion, built-in loudspeaker and 3.5mm TRS headphones Fully Digital Congress System Delegate Unit (flush-mounting, jack, black) discussion, 64 CHs, OLED, black)
  • Page 63 HCS-4840DHT Nameplate management system or Nameplate server needed, Multi-function Connector (for connection black) HCS-1082SN_W HCS-4842DHT channel selectors, silver) HCS-4842DHT E-ink Electronic Nameplate (tabletop, single screen, 14.74”, 64-Channel Selector (flush-mounting, HCS-4840DHT needed, microphone status indicator, USB connector to HCS-86** series black) multimedia congress terminal, RJ45 connector supports PoE, HCS-4841DMIC Nameplate management system or Nameplate server needed,...
  • Page 64: Hcs-4890N/80 Series Congress Unit

    3.3 HCS-4890N/80 Series Congress Unit 3.3.1 Functions and Indications Front of HCS-4890NCVSE/80 Front of HCS-4890NDVSE/80 Front of HCS-4890NCS/80 Front of HCS-4890NDS/80 Left of HCS-4890N/80 series Right of HCS-4890N/80 series Rear of HCS-4890N/80 series Back of HCS-4890N/80 series Figure 3.3.1a HCS-4890N/80 series congress units...
  • Page 65 Front of HCS-4890NCVSE/FM/80 Front of HCS-4890NDVSE/FM/80 Back of HCS-4890N/FM/80 Figure 3.3.1b HCS-4890N/FM/80 series congress units Figure 3.3.1: 1. Stem microphone socket sign-in, voting, etc. can be operated by using the 2. Built-in Hi-fi loudspeakers physical keys on the machine panel or by touching ...
  • Page 66  If the ring mode is configured as “ON”, a ring tone 8. Earphone volume key will be produced when this key is pressed. 9. Micro USB interface  Reserved. 6.Microphone/request key with indicating light (for the delegate unit): 10.Earphone jack(Ø3.5mm) ...
  • Page 67: Installation

    3.3.2 Installation 3.3.2.1 Fixed installation of HCS-4890N/80 Series Congress Unit As shown figure above, cut two Ø 4.5 mm holes in the table, spacing 100 mm. Use M4 screw(length 25mm)in accessory to rotate the screw upwards from the bottom of the desktop and insert it into the fixing hole of the congress unit(thickness 20mm of table is required).
  • Page 68 As shown in the picture above, place the HCS-4890N/FM/80 conference unit in the opening, first insert the U-shaped patch  through the screw at the bottom of the desktop, and place the two ends on the side of the mounting hole, and then tighten it with the wing nut .
  • Page 69: Connection

    3.3.3 Connection 3.3.3.1 Connecting to the CMU or the EMU Neither the replacement of congress units nor cable faults between congress units will affect the other units The HCS-4890N series congress unit is equipped with if “Closed Loop - Daisy Chain” connection topology is a 1.5-meter 8P-DIN cable with a standard male selected.
  • Page 70 3.3.3.3 External earphone An external earphone can be connected to the external earphone jack of the congress unit. Its volume can be adjusted by the earphone volume control button. The external earphone shall have a Ø 3.5 mm plug, as the following figure: Functions and indications: Left stereo channel signal...
  • Page 71: Operation

    3.3.4 Operation Before a meeting starts, the congress units need to be screen for information display, during the meeting, the configured by the operator, including: numbering and participators can use the congress unit to sign-in, testing. Congress unit exquisite and sleek 4.3" touch activate microphone, request to speak, vote, etc.
  • Page 72 3.3.4.2 Delegate unit B. “Override” mode ■ Active microphone number limitation (1~8) NOT We introduce all the operation of HCS-4890N series congress units. The congress units of this series reached: feature one or more of these functions. a. The microphone will be activated when the microphone On/Off key is pressed, the speaker 1.
  • Page 73 b. When his/her request is approved, he/she can speak and the last activated microphone will be turn off at the same time. E. “PTT” mode  Active microphone number limitation (1~8) NOT reached: If "Allow belated sign-in after stop" is enabled, when a.
  • Page 74  When the earphone is plugged, its volume can be 4. Voting (for units with function) adjusted by the earphone volume control of the Voting can be originated by TAIDEN conference terminal. management system software.  The voting option will be displayed on LCD, click on the option button to vote;...
  • Page 75 3.3.4.3 Chairman unit same time. When a request is approved, the last activated microphone will be turn off at the same time. The chairman unit features all the functions of a delegate unit, and the following additional functions: B. Turn off or mute delegate microphone 1.
  • Page 76: Hcs-4838 Series Congress Unit

    3.4 HCS-4838 series congress unit 3.4.1 Functions and indications HCS-4838CS chairman unit HCS-4838DS delegate unit HCS-4838C chairman unit HCS-4838DS delegate unit HCS-4838R series congress unit Side of HCS-4838 series...
  • Page 77 Back of HCS-4838 series Back of HCS-4838R series Figure 3.4.1 HCS-4838 series congress units Figure 3.4.1: 1.Priority key with indicating light (for the chairman Work state Indicating light unit only): Microphone On Red (on)  According to the priority mode configuration on the Request to speak Green (on) main unit:...
  • Page 78: Connection

    3.4.2 Connection 3.4.2.1 Connecting to the CMU or the EMU Neither the replacement of congress units nor cable The HCS-4838 series congress unit is equipped with a faults between congress units will affect the other units 1.5-meter 8P-DIN cable with a standard male if “Closed Loop - Daisy Chain”...
  • Page 79 Figure 3.4.5 “Daisy-chain” connection between HCS-4838 series congress units 3.4.2.3 External earphone An external earphone can be connected to the external earphone jack of the congress unit. Its volume can be adjusted by the earphone volume control button. The external earphone shall have a Ø 3.5 mm plug, as the following figure: Functions and indications: Left stereo channel signal...
  • Page 80: Operation

    3.4.3 Operation b. The microphone will be deactivated when the Before a meeting starts, the congress units need to be microphone On/Off key is pressed again. configured by the operator, including: numbering and testing. During the meeting, the participators can use ...
  • Page 81  Any delegate unit can be assigned as a VIP unit by a. The microphone will be activated when the the TAIDEN conference management system microphone On/Off key is pressed and held, the software. At most 32 VIP units can be assigned;...
  • Page 82 3.4.3.2 Chairman unit The chairman unit features all the functions of a delegate unit, and the following additional functions: 1. Priority  If the priority mode on the main unit is configured as “All mute”, all active delegate microphones (except VIP units) will be muted temporarily when this key is pressed and they will restore when this key is released;...
  • Page 83: Hcs-48U6 Series Congress Unit

    3.5 HCS-48U6 series congress unit 3.5.1 Functions and indications HCS-48U6CMICM/80 flush-mounted chairman unit HCS-48U6DMICM/80 flush-mounted delegate unit HCS-48U6CMICMS flush-mounted chairman unit HCS-48U6DMICMS flush-mounted delegate unit HCS-48U6SELM/80 flush-mounted channel selector HCS-48U6SPK HCS-48U6DVOTTW flush-mounted voting unit HCS-48U6DVOTFW flush-mounted voting unit Bottom of HCS-48U6MICM/80 Bottom of HCS-48U6MICMS Bottom of HCS-48U6SELM/80 Bottom of HCS-48U6DVOT...
  • Page 84 Figure 3.5.1:  In different modes, the corresponding indicating 1. Stem microphone socket 2. Priority key with indicating light (for the lights blink; press the corresponding key to chairman unit only): execute operation (refer to table 3.5.1 for details).  According to the priority mode configuration on the 9.
  • Page 85 Table 3.5.1 List of multi-functional keys - 3 keys Function Keys × Numbering Number Sign-in Sign-in Parliamentary ABSTAIN For/Against Against Satisfied/ Basically satisfied/ Unsatisfied/ 3 keys voting Qualified/ Basically qualified/ Unqualified/ Competent Basically competent Incompetent Satisfied/ Unsatisfied/ 2 keys voting Qualified/ Unqualified/ Competent...
  • Page 86: Installation

    3.5.2 Installation 3.5.2.1 Stand-alone installation ■ Installation a. Make holes on the table according to the dimensional diagram; b. Fix the fixed iron plates with self tapping screws (KA3×12) according to the holes; c. Hook up the unit onto the fixed iron plates. Figure 3.5.4 Disassembly caution of HCS-48U6 series flush-mounted congress unit Figure 3.5.2 Positioning diagram of HCS-48U6 series...
  • Page 87 Figure 3.5.6 Installation diagram of HCS-48U6SPK...
  • Page 88 3.5.2.2 Assembly installation a. Cut holes in the table for the first unit according to the positioning diagram (figure 3.5.7); b. Make sure that the distance between the center of the two adjacent holes is more than 100 mm; and distance center between...
  • Page 89: Connection

    3.5.3 Connection Neither the replacement of congress units nor cable 3.5.3.1 Connecting to the CMU or the EMU faults between congress units will affect the other units HCS-48U6 series (HCS-48U6MICM/80 if “Closed Loop - Daisy Chain” connection topology is HCS-48U6SELM/80) congress unit is equipped with selected.
  • Page 90 3.5.3.3 External earphone An external earphone can be connected to the earphone jack of HCS-48U6SELM channel selector. Its volume can be adjusted by the earphone volume control button. The external earphone shall have Ø 3.5 mm plug, as the following figure: Functions and indications: Left stereo channel signal Right stereo channel signal...
  • Page 91: Operation

    3.5.4 Operation Before a meeting starts, the congress units need to be blink. If the indicating light keeps on, stands that the configured by the operator, including: numbering and IC-Card is invalid; please read the IC-Card again or testing. During the meeting, the participators use the contact the technical support.
  • Page 92 4. Voting (for HCS-48U6DVOT series only) automatically. The interval time can be adjusted at the main unit (refer to section 2.1.3); Voting can be originated by TAIDEN conference c. When the microphone is activated, it can be management system software.
  • Page 93 7. VIP unit (for delegate discussion unit of this series only)  Any delegate unit can be assigned as a VIP unit by the TAIDEN conference management system software.  As long as the active microphone capacity is not full, the microphone of the VIP unit can be activated freely;...
  • Page 94 3.5.4.2 Chairman unit The chairman unit features all the functions of a delegate unit, and the following additional functions: 1. Priority (for chairman discussion unit of this series only)  If the priority mode on the main unit is configured as “All mute”, all active delegate microphones (except VIP units) will be muted temporarily when this key is pressed and they will restore when this...
  • Page 95 3.6 HCS-48U7/U8/U9 series congress unit 3.6.1 Functions and indications HCS-48U9 series front HCS-48U9DFF HCS-48U9CVSW/80 HCS-48U9DVSW/80 HCS-48U8 series front HCS-48U8CVSW/80 HCS-48U8DVSW/80 HCS-48U7 series front HCS-48U7CM/80 HCS-48U7DM/80 HCS-48U7/U8/U9 back side Bottom side of HCS-48U8/9 Bottom side of HCS-48U7M/80...
  • Page 96 HCS-48U8/U9 series side Left side Right side Figure 3.6.1 HCS-48U7/U8/U9 series congress units Figure 3.6.1: 1. Built-in Hi-Fi loudspeaker the microphone;  Mutes automatically to suppress howling when the  Delegate unit: press this key to activate/deactivate microphone of the unit is active; the microphone or request/cancel ...
  • Page 97 18. TEST HCS-48U7MIC module. 19. SPK 22. RS-232  Connecting to HCS-48U7SPK module. 20. MIC.  6-pin socket, connecting to stem microphone of HCS-48U7MIC module. 21. EXT. MIC.  3-pin socket, connecting to external microphone of Table 3.6.1 List of multi-function keys Function Keys 1/- -...
  • Page 98 3.6.2 Installation 3.6.2.1 Cutout Figure 3.6.2 Cutout of HCS-48U7/80 series flush-mounted congress unit (unit: mm)
  • Page 99 Figure 3.6.3 Cutout of HCS-48U8/80 series flush-mounted congress unit (unit: mm)
  • Page 100 Figure 3.6.4 Cutout of HCS-48U9/80 series flush-mounted congress unit (unit: mm)
  • Page 101 Figure 3.6.5 Cutout of HCS-48U7M/80 flush-mounted congress unit (unit: mm)
  • Page 102: Installation

    3.6.2.2 Installation Figure 3.6.6 Installation of HCS-48U7/80 series flush-mounted congress unit...
  • Page 103 Figure 3.6.7 Installation of HCS-48U8 series and HCS-48U9 series flush-mounted congress unit...
  • Page 104 Figure 3.6.8 Installation of HCS-48U7M/80 series flush-mounted congress unit...
  • Page 105 3.6.2.3 Disassembly Figure 3.6.9 Disassembly of HCS-48U8 and HCS-48U9 series flush-mounted congress unit (method a) Figure 3.6.10 Disassembly of HCS-48U8 and HCS-48U9 series flush-mounted congress unit (method b)
  • Page 106 Figure 3.6.11 Disassembly caution of HCS-48U8 and HCS-48U9 series flush-mounted congress unit...
  • Page 107 3.6.3 Connection 3.6.3.1 Connection among the modules of HCS-48U7 congress unit Figure 3.6.12 Connection among the modules of HCS-48U7 congress unit...
  • Page 108: Connection

    3.6.3.2 Connecting to the CMU or the EMU connected to the output of the main unit via CBL8P2RJ45 converter cable; the other port of HCS-48U7/U8/U9 series congress unit HCS-8600MCLS is connected to the contribution unit; equipped with two RJ45 sockets, congress unit at last, connect the last contribution unit back to the connect through Cat5e cable and CBL8P2RJ45 CMU via a CBL8P2RJ45S converter cable.
  • Page 109 Functions and indications: Signal+ Suspend/Ground Ground 3.6.3.5 External earphone An external earphone can be connected to the external earphone jack of the congress unit. Its volume can be adjusted by the earphone volume control button. The external earphone shall have a Ø 3.5 mm plug, as in the following figure: Functions and indications: Left stereo channel signal...
  • Page 110: Operation

     Key-press sign-in 3.6.4 Operation In key-press sign-in status, the indicating light on key Before a meeting starts, the congress units need to be “1” will blink, press key “1” to sign-in and the indicating configured by the operator, including: numbering and light will be turned off.
  • Page 111 units in case the delegates leave for a short time. C. “Voice” mode Delegate units will work on after delegates sign-in  Active microphone number limitation (1~8) NOT again (The DCS server cannot stop sign-in). reached: a. The microphone On/Off key indicating light 3.
  • Page 112 After sign-in, the following interface will be displayed on Voting can be originated by the chairman unit (only for the LCD: 3 keys voting), or by TAIDEN conference management system software.  The voting button indicating lights of the congress unit start to blink, the delegate can press the voting button to vote;...
  • Page 113 If not, it will remind you to plug the earphone. If the current unit is using the intercom function, it will the TAIDEN conference management system remind you that the line is busy. Press “Call” (key “1”) to software. At most 32 VIP units can be assigned;...
  • Page 114 3.6.4.2 Chairman unit The chairman unit features all the functions of a B. Turn off delegate microphone or reject delegate delegate unit, and the following additional functions: unit’s request to speak 1. Priority The initial interface of the chairman unit is shown in the following figure at the left side.
  • Page 115 blink, the delegate is now enabled to vote: c. Only 3 keys voting can be executed in case of a chairman unit originated voting (“Yes/No/Abstain”) and only “Last key-press valid” is available. The chairman can pause/end voting: d. The chairman presses “End” (key “5”) to finish voting. The voting indicating light of all congress units will be deactivated.
  • Page 116: Hcs-48U10/80 Series Congress Unit

    3.7 HCS-48U10/80 series congress unit 3.7.1 Functions and indications HCS-48U10CVSE/80 chairman unit HCS-48U10DVSE/80 delegate unit HCS-48U10DVE/80 delegate unit HCS-48U10DDS/80 delegate unit Side HCS-48U10DS/80 delegate unit Bottom Figure 3.7.1 HCS-48U10/80 series congress units Figure 3.7.1: ◊ If configured as “All off”, all active delegate 1.
  • Page 117  If the ring mode is configured as “ON”, a ring tone 5. Contactless IC Card slot  Built-in contactless IC-Card slot to place the IC will be produced when this key is pressed. 2. Microphone On/Off key with indicating light (for card, while automatically logout once the card is taken out from the slot.
  • Page 118: Installation

    3.7.2 Installation Figure 3.7.2 Cutout of HCS-48U10/80 series congress unit (unit: mm)
  • Page 119 Figure 3.7.3 Installation of HCS-48U10/80 series congress unit...
  • Page 120: Connection

    3.7.3 Connection Neither the replacement of congress units nor cable 3.7.3.1 Connecting to the CMU or the EMU faults between congress units will affect the other units if “Closed Loop - Daisy Chain” connection topology is HCS-48U6 series (HCS-48U6MICM/80 selected. “Closed Loop - Daisy Chain” connection, HCS-48U6SELM/80) congress unit is equipped with achieved by closing the loop of the daisy-chained units, two RJ45 sockets supports daisy chain connection via...
  • Page 121 3.7.3.3 External earphone An external earphone can be connected to the external earphone jack of the congress unit. Its volume can be adjusted by the earphone volume control button. The external earphone shall have a Ø 3.5 mm plug, as the following figure: Functions and indications: Left stereo channel signal...
  • Page 122: Operation

    3.7.4 Operation  Key-press sign-in Before a meeting starts, the congress units need to be configured by the operator, including: numbering and In key-press sign-in status, the indicating light on key testing. During the meeting, the participators can use “YES” will blink, press key “YES” to sign-in and the the congress unit to sign-in, activate microphone, indicating light will be turned off.
  • Page 123 The interval time can be adjusted 4. Voting (for units with voting function) at the main unit (refer to section 2.1.3); Voting can be originated by TAIDEN conference c. When the microphone is activated, it can be management system software.
  • Page 124 8. VIP unit  Any delegate unit can be assigned as a VIP unit by the TAIDEN conference management system software. At most 32 VIP units can be assigned;  As long as the active microphone capacity is not full, the microphone of the VIP unit can be ...
  • Page 125 3.7.4.2 Chairman unit B. Turn off or mute delegate microphone The chairman unit features all the functions of a The chairman can use the priority key to execute “All delegate unit, and the following additional functions: mute” or “All off” operation. 1.
  • Page 126: Hcs-4860/80 Series Congress Unit

    3.8 HCS-4860/80 series congress unit 3.8.1 Functions and indications HCS-4860C/80 chairman unit HCS-4860D/80 delegate unit HCS-4860C/80/2M chairman unit HCS-4860D/80/2M delegate unit HCS-4860CS/80 chairman unit HCS-4860DS/80 delegate unit HCS-4860CX/80 chairman unit HCS-4860DX/80 delegate unit...
  • Page 127 Back of HCS-4860/80 series Back of HCS-4860/80/2M series Back of HCS-4860X/80 series Back of HCS-4860XD/80 series Figure 3.8.1 HCS-4860/80 series congress units Figure 3.8.1:  Chairman unit: press this key to activate/deactivate 1. Earphone jack (Ø 3.5 mm) 3. Priority key with indicating light (for the the microphone;...
  • Page 128 microphone with +48V phantom power (male x 1)  XLR connector for condenser microphone with 11. 0.6-meter 8P-DIN cable with standard plug +48V phantom power (female x 1) 7. OLED display 12. XLRM connector  Connect backup microphone to sound mixer 8.
  • Page 129: Connection

    3.8.2 Connection Neither the replacement of congress units nor cable 3.8.2.1 Connecting to the CMU or the EMU faults between congress units will affect the other units if “Closed Loop - Daisy Chain” connection topology is The HCS-4860/80 series congress unit is equipped selected.
  • Page 130 main microphone fails, backup microphone output is not affected, so that the meeting can carry on smoothly. See figure 3.8.6. 3.8.2.4 External earphone An external earphone can be connected to the external earphone jack of the congress unit. Its volume can be adjusted by the earphone volume control button.
  • Page 131: Operation

    3.8.3 Operation b. The microphone will be deactivated when the Before a meeting starts, the congress units need to be microphone On/Off key is pressed again. configured by the operator, including: numbering and testing. During the meeting, the participators can use ...
  • Page 132 5. VIP unit  Any delegate unit can be assigned as a VIP unit by E. “PTT” mode the TAIDEN conference management system  Active microphone number limitation (1/2/3/4) NOT software. At most 32 VIP units can be assigned; reached: ...
  • Page 133 3.8.3.2 Chairman unit 4. Voting The chairman unit features all the functions of a delegate unit, and the following additional functions: Chairman unit with voting cannot originate voting without a PC. 1. Priority When connecting with PC software:  If the priority mode on the main unit is configured ...
  • Page 134: Hcs-4840Dht & Hcs-4842Dht

    3.9 HCS-4840DHT & HCS-4842DHT 3.9.1 Functions and indications HCS-4840DHT Multifunctional connector HCS-4842DHT Channel selector Figure 3.9.1 HCS-4840DHT and HCS-4842DHT Figure 3.9.1 1. CH. Selector  Connecting to RJ45 socket of HCS-4842DHT. 2. 8P-DIN cable standard socket (female x 1) 3. 2.1-meter 8P-DIN cable with standard plug (male x 1) 4.
  • Page 135: Installation

    3.9.2 Installation ■ Disassembly ■ Installation When disassembling, insert a screwdriver from the bottom, a. Make holes on the table according to the release the buckle, raise it from one side, then raise the dimensional diagram; other side, and lift the unit. b.
  • Page 136 Figure 3.9.1 CMU connecting to HCS-4840DHT For a longer distance between the contribution unit and Figure 3.9.3 “Closed Loop - Daisy Chain” connection the CMU/EMU, a CBL8PSD extension cable can be topology used. One end of this cable is equipped with a 8P-DIN male connector, the opposite end is equipped with a 3.9.3.2 Connections...
  • Page 137: Operation

    2. Volume control (only for units with simultaneous interpretation)  When the earphone is plugged, its volume can be adjusted by the earphone volume control of the unit. Figure 3.9.5 HCS-4840DHT multi-function connector connected to HCS-4842DHT channel selector 3.9.3.4 External earphone An external earphone can be connected to the earphone jack of HCS-4842DHT channel selector.
  • Page 138: Hcs-4841Dmic Multifunction Connector

    3.10 HCS-4841DMIC Multifunction Connector 3.10.1 Functions and indications HCS-4841DMIC Multifunction Connector 1&2 RJ45 cable  Use for “Daisy-chain” connection  Recommended use of cat5e cable with a drain wire & RJ45 plug with metal shield, CBL8P2RJ45S converter cable connect to the EMU 3.
  • Page 139 3.10.2 Connection 3.10.2.1 Connect to the CMU or EMU HCS-4841DMIC multifunction connector have 2 RJ45 cable and adopt CBL8P2RJ45S converter cable for CMU connection while multifunction connector connect through daisy chain. One HCS-4841DMIC can connect 2 condenser microphone and 2 microphone switch button.
  • Page 140 3.11.1 Button Installation a. Cut holes in the table for the first unit according to the positioning diagram (figure 3.11.1); Figure 3.11.1 button installation (unit: mm) b. Take off the hexagon nut; Put the cable cross from top to bottom of hole of the table d.
  • Page 141: Hcs-4856 Lift Microphone

    3.12 HCS-4856 Lift Microphone 3.12.1 Function and indications HCS-4856C lift microphone chairman unit front HCS-4856C lift microphone delegate unit front Figure 3.12.1 HCS-4856C/D lift microphone  speak);If the chairman microphone is not active, 1. Microphone lift hole 2.Up button pressing this key will activate it; Press the Up button, the microphone goes up 3.Pause button 6.Microphone On/Off key with indicating light (for...
  • Page 142 Top of HCS-4856CBX/DBX lift microphone control box Button of HCS-4856CBX/DBX lift microphone control box Back of HCS-4856CBX/DBX lift microphone control box Figure 3.12.2 HCS-4856BX lift microphone control box...
  • Page 143 Figure 3.12.2 1. Microphone lift hole Embedded HCS-4856 lift microphone straw and should be use with HCS-4856 lift microphone. 2.RJ45 cable There are 2 RJ45 cables for daisy chain connection and cat5e cable with a drain wire&RJ45 plug with metal shied is recommended.
  • Page 144 3.12.2 Installation 图 3.12.2 Cutout of HCS-4856 lift microphone (unit: mm)
  • Page 145: Chapter 4 Interpreter Unit

    Chapter 4 Interpreter unit Simultaneous interpretation function of HCS-4800 series congress unit is designed for the requirements of large scale multilingual international congresses: it can provide up to 64 language channels (64 CHs). HCS-8685 interpreter unit is equipped with a 6.8” TFT LCD, a 64-channel selector, a built-in loudspeaker, a pluggable microphone, headset sockets, etc.
  • Page 146: Functions And Indications

    4.1 Functions and indications Front Side Bottom Figure 4.1 HCS-8685 Interpreter unit...
  • Page 147  When the monitor channel shortcut switch button  Listening area: (1/2/3/4/5/6/7) was pressed, push the function knob Loudspeaker/earphone control: to go to channel 1, turn the function knob to select 1. Loudspeaker volume control knob the interpretation channel; 2. Built-in Hi-Fi loudspeaker ...
  • Page 148 ** asks for help” will be displayed on the LCD of Special configuration: operator unit. Braille 13. Slow key (SLOW)  Ergonomic design with features for visually  If selected “Allow Slow” and set the requisite impaired. number by application software (Control – Booth Manage.
  • Page 149: Connection

    4.2 Connection 4.2.1 Connecting to the CMU or the EMU For “Closed Loop - Daisy Chain” ring connection, HCS-8685 interpreter unit is equipped with a cable with a HCS-8600MCLS Loop switcher is needed. The "TO MU" standard 8P-DIN male connector. When connecting the port of HCS-8600MCLS is connected to the output of the CMU to the contribution units, just connect the male main unit via CBL8P2RJ45 converter cable;...
  • Page 150: External Earphone

    Functions and indications: Left stereo channel signal Right stereo channel signal Power ground/Shield External microphone signal Figure 4.6 “Daisy-chain” connection between HCS-8685 Interpreter units 4.2.3 External earphone An external headphone can be connected to the TRRS jack at the lateral side of the Interpreter unit. Its volume can be adjusted by the earphone volume control knob.
  • Page 151: Setup

    4.3 Setup To realize the simultaneous interpretation function, the Example: interpreter unit should be incorporated in the congress Booth 1 is for translation between English/Chinese. system and they should be setup before the meeting. Output channel A is English, output channel B is Chinese, Any operating status of the interpreter unit will be and output channel C is “None”.
  • Page 152 Figure 4.7 Direct interpretation Figure 4.8 Relay interpretation Figure 4.9 Schematic diagram of the connection of interpreter units...
  • Page 153: Lcd Configuration Menu

    4.3.2 LCD configuration menu When the “Interpretation setup” has been configured in the CMU, and then the interpreter unit must be configured:  If the interpreter unit has not been configured, the LCD will display “UNIT NOT INSTALLED”; In the following operation: ...
  • Page 154 If you select App, press the Function button to open Compressor QR code interface, scan the QR code according to you On or Off compressor. phone or pad to download Taiden SI tool App. After installation, you can send message to all or part booths via Bluetooth. Setting Input Pincode first before enter setting interface, 1).
  • Page 155 Blue:...
  • Page 156: Other Configuration

    4.3.3 Other configuration 4.2.4.3.3 Interlock mode 4.2.4.3.1 Input channel configuration Interpretation mode can be setup by menu operation The HCS-8685 equipped with 7 pre-select buttons on the main unit (refer to section 2.1.3): (1/2/3/4/5/6/7) for relay languages with activation Interlock mode between booths: indication on the LCD.
  • Page 157: Operation

    4.4 Operation 4.4.1 Operation of listening area 6. Quality indication: The second line of the display The listening area, on the left side of the unit, is the shows the qualities of the interpretations on the area used to monitor the floor or the interpretation channels that are assigned to the pre-select buttons channels.
  • Page 158: Operation Of Speaking Area

    4.4.2 Operation of speaking area 6. “HELP” button: If selected “Allow Help” by The speaking area, on the right side of the unit, is the application software (Control – Booth Manage. – area which is used to distribute the interpretation Param.
  • Page 159: Chapter 5 System Connection And Basic Setup Procedure

     When the extension cable is longer than 60 meeting flexibly. meters, please be sure to replace the cat5e In this chapter, the connections of HCS-4800 series fully cable with braided shield; digital congress system are introduced by diagrams and ...
  • Page 160 Table 5.1.1 Quick lookup table of HCS-4800M CMU and HCS-8600M EMU load capability (each outlet) The extension cable length between the CMU(EMU) and the first Congress Unit Type Type No. connected to the socket 20 m 40 m 60 m 80 m Equipped with 6.8”...
  • Page 161: Connection Between The Cmu/Emu And The Contribution Units

    5.1.2 Connection between the CMU/EMU and the contribution units HCS-4800 series congress units feature a 1.5 m 8P-DIN makes the installation handy and effortless. Connect the standard male plug cable and a 0.6 m 8P-DIN female unit to the outlet connector of the CMU, and following plug cable (HCS-4840DHT feature a 2.1 m 6P-DIN...
  • Page 162: Connection Between Hcs-4800 System And Automatic Video Tracking System

    5.1.3 Connection between HCS-4800 system and automatic video tracking system HCS-4800 series fully digital congress system can be The video tracking system is composed of video switcher, connected to an automatic video tracking system. For button board and high-speed dome camera.
  • Page 163: Connection Between Hcs-4800 System And Conference Sign-In System

    5.1.4 Connection between HCS-4800 system and Conference Sign-in System Conference Sign-in System aims at providing the reliable, can choose as needed), meanwhile, personalized effective and convenient congress sign-in solution for portrait and design can be printed onto the surface of the various large congress.
  • Page 164: Basic Configuration Of A Congress System

    5.2 Basic configuration of a congress system The basic configuration is described below by a simple example. This system is composed of one HCS-4800MA CMU, one HCS-8600MEA EMU, four HCS-8685 interpreter units, ten HCS-48U10/80 discussion units (including chairman unit delegate units) five HCS-4890N/80 discussion units (including chairman unit...
  • Page 165 According to the requirements of the specific case in this 2. Configurate Interpreter units in booth 1 (the section, the configuration is as the following: configuration of both Interpreter units is the same) 1. Configuration CMU a) Channel B output: pressing output channel B switch and rotating Primary knob at the same time, and set a) Active microphone number limitation: active Chinese as channel B output language.
  • Page 166: Chapter 6 Peripheral Equipment And Accessories

    Chapter 6 Peripheral equipment and accessories 6.1 Microphone  Removable stem microphone Direction: Functions and instructions: 1. Electret condenser cardioid microphone 2. Two-color microphone on/off LED ring (default) Indicating light Work state of LED ring Microphone On Red (on) Speaking time limit Red (flash) First in request list Green (flash)
  • Page 167 Detaching of the M-model windshield a. Prepare a straight screwdriver; b. Insert the straight screwdriver into the gap of the microphone and press the straight screwdriver. The M-model windshield will be separated from the stem microphone.  HCS-1020 clip microphone...
  • Page 168: Earphones

    6.2 Earphones The jack plug of the stereo headphone can be inserted  EP-960BH Interpreter headphone into a Ø 3.5 mm stereo headphone jack socket. Applicable types include:  EP-830 Single earphone  EP-960HD Detachable Earshells  EP-820AS Single earphone ...
  • Page 169: Accessories

    6.3 Accessories Some dedicated accessories are involved in the connection of conference system devices. Herein, these accessories are introduced, including: ♦ CBL8PS dedicated 8-pin Extension Cable ♦ CBL8PP-02 dedicated 8-pin Extension Cable ♦ Solderable 8DIN Standard Socket (insulating) ♦ HVS-620P Video display card ♦...
  • Page 170 CBL8P2RJ45S-01 8-pin to RJ45 converter cable CBLRJ45 Ethernet Extension Cable  Suitable for HCS-4800 series and HCS-8600  Used for HCS-4800 series, HCS-8600 series and series conference systems education equipment  Standard connectors (8P-DIN male plug at one  Cable: FTP CABLE with drain wire ...
  • Page 171  HCS-8600MCLS/F Loop Switcher is for connection between the primary and secondary CMU.  "TO MU" socket for connection to the primary CMU  The other socket for connection to the secondary CMU  HCS-MCLS-RCF and HCS-MCLS-FC can be 12. HCS-4852TN RJ45 cable divider chosen ...
  • Page 172: Chapter 7 Working Environment And Maintenance

    The covers should only be removed attention to: by qualified service personnel. If any repair or  Terminating and maintenance of optical fiber maintenance is required, contact the TAIDEN should be carried out by strictly trained technical service center in your region.  staff;...
  • Page 173: System Operator Room

     In the hall, booths should be set up at the back or sideways.  Booths should be elevated to provide an overall, unobstructed direct view of the chairman, the speakers and any other relevant visual aids.  A window should be installed at the forefront of the booth across the overall length.
  • Page 174: Chapter 8 Technical Specifications

    Chapter 8 Technical specifications 8.1 System specifications System performance Conforms to ISO 22259, the international standard for congress systems System environmental conditions Working conditions fixed/stationary/transportable Temperature range: - Transport: -40 °C to +70 °C - Operating: 0 °C to +45 °C Max.
  • Page 175: Congress System Main Unit

    8.2 Congress system main unit 8.2.1 Congress main unit 8.2.1.1 Physical characteristics Types HCS-4800M series Installation Tabletop / standard 19-inch rackmount Dimensions (mm) Color Black (PANTONE 419 C) Weight 7.9 kg...
  • Page 176 Electrical characteristics 8.2.1.2 Types HCS-4800MA HCS-4800MB HCS-4800MC ≤4096 Microphone capacity Channels 64CHs 30 - 20000 Hz Frequency response ≥100 dBA ≥94 dB Dynamic range ≥90 dB Crosstalk Total harmonic ≤0.05% distortion Mains power supply AC 100 V - 240 V 50/60 Hz LINE IN 1: +10 dBu balanced Input impedance: >10 kΩ...
  • Page 177: Congress Extension Main Unit

    8.2.2 Congress extension main unit 8.2.2.1 Physical characteristics Types HCS-8600MEA Series Installation Tabletop / standard 19-inch rackmount Dimensions (mm) Color Black(PANTONE 419 C) 3.6 kg Weight 8.2.2.2 Electrical characteristics Types HCS-8600MEA Series Mains power supply AC 100 V - 120 V 60 Hz >1 kΩ...
  • Page 178: Congress Extension Main Unit

    8.2.3 Congress extension main unit 8.2.3.1 Physical characteristics Extension unit HCS-8600MES Installation Tabletop / standard 19-inch rackmount Dimensions (mm) Color Black(PANTONE 419 C) Weight 1.5 kg 8.2.3.2 Electrical characteristics Extension host HCS-8600MES Mains power supply AC 100 V - 240 V, 50 Hz / 60 Hz >1 kΩ...
  • Page 179: Hcs-4890N/80 Series Congress Unit

    8.3.2 HCS-4890N/80 series congress unit 8.3.2.1 Physical Characteristics Types HCS-4890N/80 series Installation Tabletop Dimensions (mm) Color Black (PANTONE 419 C) Weight 1.1 kg 8.3.2.2 Electrical Characteristics Types HCS-4890N/80 series Output frequency 30 - 20000 Hz response ≥16 Ω Earphone load 10 mW Earphone volume Earphone output...
  • Page 180 8.3.3 HCS-4890N/80 series congress unit 8.3.3.1 Physical Characteristics Types HCS-4890N/FM/80 series Installation Flush-mounted Dimensions (mm) Color Black (PANTONE 419 C) Weight 0.9 kg 8.3.3.2 Electrical Characteristics Types HCS-4890N/FM/80 series Output frequency 30 - 20000 Hz response ≥16 Ω Earphone load 10 mW Earphone volume Earphone output...
  • Page 181: Hcs-4838 Series Congress Unit

    8.3.4 HCS-4838 series congress unit 8.3.4.1 Physical Characteristics Types HCS-4838 series Installation Tabletop Dimensions (mm) The size of microphone of HCS-4838R is 194X31X20mm. HCS-4838 series: charcoal gray (PANTONE Cool Gray 11 C) Color HCS-4838R series: black microphone (PANTONE 419 C) charcoal gray base (PANTONE Cool Gray 11 C) HCS-4838 series: 0.9 kg Weight...
  • Page 182 8.3.4.2 Electrical Characteristics Types HCS-4838 Output frequency 30 - 20000 Hz response ≥16 Ω Earphone load Earphone volume 10 mW Earphone output Ø 3.5 mm stereo jack Max. power 1.9 W consumption Connection 8P-DIN dedicated cable with buckle Microphone parameters of HCS-4838 Uni-directional electret condenser microphone Type Sensitivity...
  • Page 183: Hcs-48U6/80 Series Congress Unit

    8.3.5 HCS-48U6/80 series congress unit 8.3.5.1 Physical characteristics Types HCS-48U6/80 Installation Flush-mounted Dimensions (mm)
  • Page 184 Color Black (PANTONE 419 C) 0.35 kg (HCS-48U6MICM HCS-48U6SELM) 0.08 (HCS-48U6MICS HCS-48U6DVOT) Weight 0.18 kg (HCS-48U6SPK) 8.3.5.2 Electrical characteristics Types HCS-48U6/80 Output frequency 30 - 20000 Hz response >16 Ω Earphone load Earphone volume 10 mW Earphone output Ø 3.5 mm stereo jack Max.
  • Page 185: Hcs-48U7/U8/U9 Series Congress Unit

    8.3.6 HCS-48U7/U8/U9 series congress unit 8.3.6.1 Physical characteristics Types HCS-48U7/U8/U9/80 Installation Flush-mounted Dimensions (mm)
  • Page 186 Color Black (PANTONE 419 C) 0.7 kg (HCS-48U7M/80) 1.0 kg (HCS-48U7/U8) Weight 0.9kg (HCS-48U9) 8.3.6.2 Electrical characteristics Types HCS-48U7/U8/U9/80 Output frequency 30 - 20000 Hz response >16 Ω Earphone load Earphone volume 10 mW Earphone output Ø 3.5 mm stereo jack 2.3 W (with 256×32 LCD) Max.
  • Page 187: Hcs-48U10/50 Series Congress Unit

    8.3.7 HCS-48U10/50 series congress unit 8.3.7.1 Physical Characteristics Types HCS-48U10/80 Installation Flush-mounted Dimensions (mm) Note: the height for HCS-48U10DDS/80 and HCS-48U10DS/80 is 51 mm. Color Black (PANTONE 419 C) Weight 0.8 kg 8.3.7.2 Electrical Characteristics Types HCS-48U10/80 Output frequency 30 - 20000 Hz response >16 Ω...
  • Page 188: Hcs-4860/4865/4866 Series Congress Unit

    8.3.8 HCS-4860/4865/4866 series congress unit 8.3.8.1 Physical Characteristics Types HCS-4860/80 Installation Tabletop Dimensions (mm) The length of microphone of HCS-4860/80 is 241 mm. The length of microphone of HCS-4860/80/2M is 249 mm. Color Black (PANTONE 419 C) HCS-4860/80: 1.1 kg Weight HCS-4860/80/2M: 1.2 kg HCS-4860X/80: 0.6 kg...
  • Page 189 8.3.8.2 Electrical Characteristics Types HCS-4860/80 Output frequency 30 - 20000 Hz response >16 Ω Earphone load Earphone volume 10 mW Earphone output Ø 3.5 mm stereo jack Max. power 1.8 W consumption Connection 8P-DIN dedicated cable with buckle Microphone parameters of HCS-4860/4865 Type Supercardioid uni-directional electret condenser microphone Sensitivity...
  • Page 190: Hcs-4840Dht Multi-Function Connector

    8.3.9 HCS-4840DHT multi-function connector 8.3.9.1. Physical Characteristics Types HCS-4840DHT Installation Fixed installation Dimensions (mm) Color Charcoal gray (PANTONE Cool Gray 11 C) 0.9 kg Weight 8.3.9.2. Electrical Characteristics Types HCS-4840DHT Interface 4 channel selectors Max. power 2.1 W consumption Connection 8P-DIN dedicated cable with buckle...
  • Page 191: Hcs-4842Dht Channel Selector

    8.3.10 HCS-4842DHT channel selector 8.3.9.1. Physical Characteristics Types HCS-4842DHT Installation Flush-mounted Dimensions (mm) Color Black (PANTONE 419 C) Weight 0.1 kg 8.3.9.2. Electrical Characteristics Types HCS-4842DHT Output frequency 30 - 20000 Hz response >16 Ω Earphone load Earphone volume 10 mW Earphone output Ø...
  • Page 192: Hcs-4856 Lift Microphone

    8.3.11 HCS-4856 Lift Microphone 8.3.11.1 Physical Characteristics Types HCS-4856C/D Installation Flush-mounted Dimensions (mm) Note:We suggest that the height of table should be over 720mm Color Black(PANTONE 419 C) Weight 3.7kg...
  • Page 193 8.3.11.2. Electrical Characteristics Types HCS-4856C/D Output frequency response 30 - 20000 Hz Max. power consumption 2.1W Connection mini 8P-DIN dedicated cable connect to HCS-4856DBX Type Supercardioid uni-directional electret condenser microphone Sensitivity -46 dBV/Pa Frequency response 50 - 20000 Hz Input impedance 2 kΩ...
  • Page 194 8.3.11.2 Physical Characteristics 会议单元 HCS-4856BX Dimensions (mm) Black(PANTONE 419 C) Color Weight 0.4kg Electrical Characteristics 8.3.11.3 Type HCS-4856BX Output frequency response 30 - 20000 Hz Max. power consumption 2.7 W Cat.5 cable with standard RJ45 plug Connection...
  • Page 195: Peripheral Equipment And Accessories

    8.5 Peripheral equipment and accessories 8.5.1 Pluggable stem microphone 8.5.1.1 Physical Characteristics Types MS33EGB1S/B MS41EGB1S/B MS47EGB1S/B Installation Insert microphone and tighten Length 330 mm 410 mm 470 mm Silver (PANTONE 428 C) / Black (PANTONE 419 C) Color Weight 91 g 98 g 105 g Types...
  • Page 196: Earphone

    8.5.2 Earphone  Frequency response of headphone: 20 Hz to 20  EP-830 single earphone  Used with interpretation receiver or on a Sensitivity of headphone: ≥108 dBA/1 mW  conference unit  Polar pattern of microphone: Omnidirectional  Hi-Fi sound quality ...
  • Page 197: Accessories

    CBL8PP-02 dedicated 8-pin Extension Cable  Male connector at both ends  CBLRJ45 Ethernet Extension Cable  Length: 2 m  Used for HCS-4800 series, HCS-8600 series and education equipment  Solderable 8P-DIN Standard Socket  Cable: FTP CABLE with drain wire ...
  • Page 198   HCS-4852TN RJ45 cable divider HCS-4345NF/50 Fingerprint Scanner  Relay facility, amplification of the communication  Cooperates with PC to take the delegate’s signals fingerprint to realize biometric authentication with  RJ45 interfaces, "1 in / 4 out " structure for high reliability ...
  • Page 199: System Connection

    8.6 System connection 8.6.1 Mains cables Blue Neutral Brown Hot (Phase) Green/Yellow Earth/Ground 8.6.2 Audio cables 3-pole XLR connector (female) Pin 1 Earth Pin 2 Signal + Pin 3 Signal - Chinch connector (male) Pin 1 Signal + Pin 2 GND 8.6.3 Earphone 3.5 mm Jack plug Tip (1) Signal left...
  • Page 200: Display Language List

    8.7 Display language list Chinese English Chinese English 639-3 639-2/5 639-1 639-3 639-2/5 639-1 原声 爱尔兰语 Floor Irish 阿尔巴尼亚 哈萨克语 Albanian Kazakh 阿拉伯语 吉尔吉斯语 Arabic Kirghiz 保加利亚语 老挝语 Bulgarian 加泰罗利亚 蒙古语 Catalan Mongolian 汉语 尼泊尔语 Chinese Nepali 捷克语 塔吉克语 Czech Tajik 丹麦语...
  • Page 201 Chinese English Chinese English 639-3 639-2/5 639-1 639-3 639-2/5 639-1 奥里亚语 茨瓦纳语 Oriya Tswana 旁遮普语 乌尔都语 Panjabi Urdu 罗曼什语 威尔士语 Romansh Welsh 梵文 祖鲁语 Sanskrit Zulu 信德语 壮族语 Sindhi Zhuang Sinhala / 僧加罗语 傣族语 Sinhalese Southern Sotho / 梭托语 维吾尔语 Uighur Sotho 斯瓦西里语...
  • Page 202: Appendix:custom-Made Cable

    Appendix:Custom-made cable...
  • Page 203 TAIDEN INDUSTRIAL CO., LTD. 6/F, Block B, Future Plaza, 4060 Qiaoxiang Rd, Nanshan District, Shenzhen, China P.C.: 518053 Copyright by TAIDEN Website: http://www.taiden.com Last Revision: 06/2022...

Table of Contents