Taiden hcs-8300 Installation And Operation Manual

Taiden hcs-8300 Installation And Operation Manual

New generation paperless multimedia congress system
Table of Contents

Advertisement

Quick Links

New Generation Paperless Multimedia Congress System
Digital Congress System
Installation and Operating Manual
V 1.8

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the hcs-8300 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Taiden hcs-8300

  • Page 1 New Generation Paperless Multimedia Congress System Digital Congress System Installation and Operating Manual V 1.8...
  • Page 2 Contents may change without prior announcement  All technical specifications are guideline data and not guaranteed features  Taiden Co., Ltd. is not responsible for any damage caused by improper use of this manual  The equipment must be connected to earth! ...
  • Page 3: Important Safety Instructions

    TAIDEN Service Center. should be easy to operate. The apparatus should be connected to the MAINS 20. All TAIDEN products are guaranteed for definite time (see the WARRANTY CARD for details) excluding the socket-outlet with protective earth.
  • Page 4 Important Safety Instructions The exclamation mark within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance (servicing) instructions in the literature accompanying the appliance. WARNING: To reduce the risk of fire or electric shock, DO NOT expose units to rain or moisture.
  • Page 5: Table Of Contents

    Contents Installation & User Guide ......................VIII Chapter 1. Introduction ....................... 1 1.1 Summary ..................................1 1.2 System equipment ..............................16 1.2.1 Congress main unit (CMU) ............................16 1.2.2 Contribution units ..............................16 1.2.3 Interpreter unit ................................16 1.3 Application software ..............................16 1.4 Functions and features ..............................
  • Page 6 5.1.2 Connection between the CMU/EMU and the contribution units ................139 5.1.3 Connection between HCS-8300 PMCS and automatic video tracking system ............140 5.1.4 Connection between HCS-8300 PMCS and digital infrared language distribution system ........141 5.1.5 Connection between HCS-8300 PMCS and central control system ................ 143 5.1.6 Connection between HCS-8300 PMCS and Conference Sign-in System ...............
  • Page 7 6.5.3 Configuration and operation ............................ 183 6.6 HCS-8300KMX ................................186 6.6.1 Functions and instructions ............................186 6.6.2 Connection ................................186 6.7 HCS-8300PM/PM2 ..............................187 6.7.1 Functions and instructions ............................187 6.7.2 Connection ................................188 6.8 HCS-8319 ................................. 189 6.8.1 Functions and instructions ............................189 6.8.2 Connection ................................
  • Page 8 8.5.5 HCS-8302MX/FS ..............................224 8.5.6 HCS-8300KMX ................................ 225 8.5.7 HCS-8300PM/PM2 ..............................226 8.5.8 HCS-8319 ................................227 8.5.9 HCS-8301 ................................228 8.5.10 Microphone ................................229 8.5.11 Earphone ................................230 8.5.12 Accessories ................................232 8.6 System connection ..............................234 8.6.1 Mains cables ................................234 8.6.2 Audio cables ................................
  • Page 9: Installation & User Guide

    Chapter 2:Congress main unit Detailed descriptions of the functions and indications, installation and connection, configuration and operation of the HCS-8300 PMCS congress main unit (CMU), extension main unit (EMU) and the extension unit (HCS-8300MES). Chapter 3:Congress unit...
  • Page 10 Installation & User Guide  Congress Unit This manual is applicable to: HCS-8338 Series:  Congress main units HCS-8338AC(-NP) chairman unit, Chinese panel HCS-8300MAU/FS HCS-8338ACE(-NP) chairman unit, English panel Fully Digital Congress System Main Unit (discussion, voting, 64 HCS-8338AD(-NP) delegate unit, Chinese panel CHs, 256x32 LCD, MIC.
  • Page 11 Installation & User Guide conference functions, video conversation, video display, multiple New Generation Paperless Multimedia Congress Terminal (10" channel VOD and broadcasting, conference service, built-in 1280×800 LCD, capacitive touch panel, camera with 5 megapixel, contactless IC-Card reader, fingerprint identification, internet speech, voting, 64 CHs, paperless conference functions, video access, built-in E-ink nameplate (“-NP”...
  • Page 12 Installation & User Guide  HCS-8385 Congress Room Combiner Fully Digital Congress System Interpreter Unit (64 CHs, 7.2” TFT HCS-8300MX Congress Room Combiner LCD, microphone, loudspeaker)  Booth Combiner  8 Channels Audio Output Devices HCS-8300MX/FS HCS-8300MOD/FS Booth Combiner (single-mode optical fiber interface) 8 Channels Audio Output Device (AES/EBU digital outputs, analog outputs, single-mode optical fiber interface, CobraNet ...
  • Page 13 Installation & User Guide  Clip microphone HCS-1020 Clip Microphone  Earphone EP-820AS Single earphone EP-829 Single earphone Single earphone (Built-in magnetic EP-829SW control switch) Interpreter headset (for HCS-8385) EP-960AN Interpreter headset (for EP-960AH HCS-4385U/50) EP-960BH Interpreter headphone HCS-5100PA Headphone...
  • Page 14: Chapter 1. Introduction

    Chapter 1. Introduction 1.1 Summary In 2010, TAIDEN developed the first paperless In 2014, TAIDEN continued to lead the development of multimedia conference system in the world. Paperless conference system technology, and introduced a new conference, video service, conference services, etc.
  • Page 15 ■ Operating the variety of desktop devices is very complicated TAIDEN integrated abundant high-end conference system application and design experience, developed the world's first multimedia conference which was based...
  • Page 16 Paperless Multimedia Congress Terminal based on photo for attendance check and record facility on TAIDEN originated GMC-STREAM Gigabit Multimedia important conferences, video conversation, video Congress Stream technology, all audio and video display, multiple channel VOD (up to 10 channels with signals are transmitted via a Cat.6 Gigabit network...
  • Page 17 Figure 1.1.3b Design sketch of HCS-8338 Series New Generation Paperless Multimedia Congress System (flush-mounting, close-up) Figure 1.1.3c Design sketch of HCS-8338 Series New Generation Paperless Multimedia Congress System (tabletop, panorama)
  • Page 18 Figure 1.1.3d Design sketch of HCS-8338 Series New Generation Paperless Multimedia Congress System (tabletop, close-up) Figure 1.1.4a HCS-8338 Series New Generation Paperless Multimedia Congress System connection diagram...
  • Page 19 Figure 1.1.4b HCS-8338 Series New Generation Paperless Multimedia Congress System connection diagram (dual main unit hot spare + “Closed Loop – Daisy Chain” connection) Primary interface Microphone Management Short Message Vote result display Simultaneous interpretation Speech text guidance - setting Media Documents reader Call service...
  • Page 20 Video conversation Take photo Video display Desktop sharing Network Figure 1.1.5 User Interfaces of New Generation Paperless Multimedia Congress System Features of HCS-8300 series Paperless Multimedia Congress Terminal: ■ Full functionality and high integration  Using daisy-chain connection topology, Various types of systems that may be involved in...
  • Page 21 EQ parameters ■ 2 audio line in (analog, digital, CobraNet/Dante) or 1 To solve above-mentioned shortcomings, TAIDEN successfully developed proprietary audio line in (analog, CobraNet/Dante) + 1 technology (utility...
  • Page 22 Figure 1.1.6 CongressMatrix Software Interface...
  • Page 23 HCS-8300 Series New Generation Paperless Multimedia A better performance is achieved in above example Congress System can be connected to a multi channel when group 1 of loudspeakers is switched off. audio amplifier and several groups of loudspeakers. Generally spoken: when the microphone in one area is...
  • Page 24 Figure 1.1.8 HCS-8300 Series Paperless Multimedia Congress System connected to a multi-channel audio amplifier with “N-1” function to cancel howl 3. Invisible microphone by microphone-array technology By adopting microphone-array technology, the sound distance from microphone. using pick-up performance of the HCS-8348 series New microphone-array, the conference room looks tidy.
  • Page 25 Figure 1.1.10 By using microphone-array terminals, the conference room looks tidy...
  • Page 26 4. E-ink nameplate 5. Duplicate and backup connection via “Closed Loop - Daisy Chain” connection topology TAIDEN has pioneered the use of E-ink nameplate with the latest E-ink technology in the industry, and it is built For important meetings, especially those which...
  • Page 27 HCS-8300 and HCS-4100/50 series Congress Units, via XLR 3-cord shielded cable. convenient for wiring and installation. All Congress Units of HCS-8300 and HCS-4100/50 10. Full system backup series (except HCS-8338 and HCS-8348 series) are In HCS-8300 series, dual connection backup is supplied by the Congress Main Unit’s 6P-DIN interface.
  • Page 28 Congress Units of the 13. Remote interpretation HCS-4100/50 series Congress System can be looped into a HCS-8300 Congress System. But some In conjunction with a HCS-8300MI/MO and a telephone exclusive functions are only available on HCS-8300 coupler, cost-saving remote interpretation function can contribution units.
  • Page 29: System Equipment

    Once the PC installed and the TAIDEN conference stand-alone mode without a PC, the CMU carries out management software integrated into the DCS, the basic management facilities. By operating TAIDEN operator manages centrally all aspects of the congress conference management software in PC-controlled centrally.
  • Page 30: Functions And Features

    ■ The first Paperless Multimedia Congress System in ■ Dual connection backup via optical fiber and Cat.5 the world cable between Congress Main Unit and Congress ■ Based on TAIDEN independent intellectual property Extension Main Unit ■ System power controllable by central control system mMediaCongress platform, never subject to viral ■...
  • Page 31: Chapter 2 Congress Main Unit (Cmu)

    The following devices can be controlled by the CMU: discussion unit(chairman unit/delegate unit), voting unit, Interpreter unit, video switch for automatic video tracking, etc. By cascade connecting EMUs, HCS-8300 system can reach its maximum capacity: 378 simultaneous Interpreter units, 4096 discussion/voting units and an infinite number of channel selectors.
  • Page 32: Fully Digital Congress System Main Unit

    2.1 Fully Digital Congress System Main Unit 2.1.1 Functions and instructions 2.1.1.1 Front panel Figure 2.1.1 Front panel of HCS-8300M CMU Figure 2.1.1 1. Power light 6. “EXIT” button  In standby state, press this button to select the a. Switches to red in standby mode; b.
  • Page 33 2.1.1.2 Backside Backside of HCS-8300MAD/FS/20 Backside of HCS-8300MAU/FS Backside of HCS-8300MB and HCS-8300MB/20 Figure 2.1.2 Backside of HCS-8300M CMU Figure 2.1.2 14. Dante interface 16. Fiber interface  Connecting the conference main unit to the  Single-mode optical fiber, SC connector; ...
  • Page 34 remote controlling; furthermore, it enables remote controlling by wireless touch panel through central control system. 18. Extension interface  To interconnect CMU, EMUs, audio input interfaces and audio output devices – units already prepared for cascade connecting. 19. Contribution units (CU) connection LED ...
  • Page 35: Installation

    2.1.2 Installation The CMU can be fixed in a standard 19-inch cabinet. The CMU is equipped with a pair of fixing brackets ①. First unscrew the lateral screws ② from the housing. Then fasten the brackets with these screws and put the CMU in the cabinet.
  • Page 36: Connection

    Figure 2.1.5 CMU connecting to contribution units 2.1.3.2 To PA The CMU of HCS-8300 PMCS has an 8 audio groups For “Closed Loop - Daisy Chain” ring connection, just output and can be directly connected to Multi Channel connect the last contribution unit back to the CMU via a Audio Amplifier to amplify the speaker’s voice.
  • Page 37 HCS-8300MAU/FS and HCS-8300MAD/FS/20 have a devices via XLR 3-cord shielded cable. pair of fiber interfaces, and can be connected to HCS-4100MA/FS/50, HCS-8300 series CMU/EMU, audio input unit, audio output unit, and two distant meeting rooms (distance can reach tens of kilometers) can be combined as one meeting room.
  • Page 38: Configuration And Operation

    2.1.4 Configuration and operation After installation and connection and prior to the hereinafter means the information displayed on the meeting, the CMU should be configured through the LCD as the “user” interface. dialog menu and button. The term “interface” used The menu structure is shown in the following figure: Figure 2.1.9 LCD menu structure of the CMU...
  • Page 39 Switch press “STANDBY” button, switch off the delegate microphone which turned HCS-8300 CMU will start initialization: on first. “Voice”: The delegate’s microphone is activated when spoken into. After 300 ms /600 ms /1 s - 15 s (adjustable) without speaking, the microphone switches off automatically.
  • Page 40 C) Access main menu 3). Use the “MENU” button to edit selected number; 4). Use the “/” button to decrease/increase the Pressing the “MENU” button under initial user interface number. To change the number quickly (= auto will go to the main menu, which includes the following repeat) press and hold the “/”...
  • Page 41   If “0” is selected, it stands for no SI function, “OVERRIDE” mode enables an interpreter in use the “MENU” button to save and return to another booth to override an occupied channel main menu; in another booth, but supplying the same ...
  • Page 42 If ALL is selected for C then g). Auto-Relay booth Setting step: select a language for B. Three channels are Setup Auto-Relay booth. now available: A and B output a selected language and C outputs any available language. If NONE is selected for C then step: select B: NONE or ALL If NONE is selected for B only A outputs the selected 1).
  • Page 43  Unit Status 2.1.4.4 Test When entering this submenu, a table consisting of the “Test” cannot work under “VOICE” and “PTT” mode, its total number, active number, and request-to-speak submenu includes: number of microphones is shown as in the following “Microphone”...
  • Page 44 e). When the second time line scan is finished, press any button to start the full screen scan; Press the “/” button to select “LED” and press the f). When the full screen scan is finished, press any “MENU” button to enter LED (indicating light) test button to return to the upper menu.
  • Page 45 2.1.4.5 Setting “Setting” submenu includes: Loudspeaker Volume Setting Adjust built-in loudspeaker volume of contribution units (except Interpreter units), range: -30 dB - 0 dB. a). Press the “/” button to adjust volume; b). Press the “MENU” button to save and return to upper level menu.
  • Page 46 b). Select LINE IN 1 mode from “Line Input” or Down Treble Setting “Microphone Input”. Press the “/” button to Adjust downlink treble of contribution units (except select “Line Input” or “Microphone Input”; Interpreter units), range: -15 dB - 15 dB. ...
  • Page 47 Microphone Gain Setting a). Press the “/” button to adjust the gain of all microphones (press and hold the “/” button will “Microphone Gain Setting” includes two submenus: adjust numeric value quickly), range: -15 dB - 15 “Set All Mics” “Set Active”...
  • Page 48  Monitor Channel Select 12. Mic. Phantom Power Setting There are two menu items for phantom power setting of Monitor Channel Select includes: group output 1-6, line hand-hold microphone interface on multi-functional unit output 1-2. HCS-4340HDA/50P. This submenu is inaccessible if no phantom unit is connected.
  • Page 49  If “No” is selected, press the “MENU” button to automatically. confirm and return to upper level menu;  If “Yes” is selected, press the “MENU” button to confirm and go to step b); a). Press the “/” button to set auto off time (press and hold the “/”...
  • Page 50 When an interpreter presses the “CALL” button on restarted after the numbering; his/her interpreter unit, he/she sets up intercom with  HCS-8300 has an auto-numbering function. the assigned congress host. “Number" function is used to allocate an ID to each contribution unit manually. This is used for...
  • Page 51 a). Press the “/” button to select “Master” or “Slave”:  If “Master Mode” is selected, press the “MENU” button to confirm and return to upper level menu;  If “Slave Mode” is selected, press the “MENU” a). Press the “/” button to select “Yes” or “No”; b).
  • Page 52 automatically by 18 dB. a). Press the “/” button to select “Yes” or “No”; b). Press the “MENU” to save and return to upper level menu. a). Press the “/” button to select “32 kHz” or “48 kHz”; 29. Floor Distribution Setting b).
  • Page 53 a). Press the “/” button to select “Yes” or “No”; 34. CobraNet/Dante Output Setting  If “Yes” is selected, force handheld microphone Enable/disable cobranet/dante output of the CMU. to PTT mode;  If “No” is selected, handheld microphone works the same as the stem microphone; b).
  • Page 54  Press the “/” button to move the cursor; 38. Touch Key Beep Setting  Press the “MENU” button to modify the Enable/disable touch key beep for HCS-4338/50 series character; congress unit. Please hear the beep through earphone.  Press the “” button to clear all the characters after the cursor;...
  • Page 55 external audio device; and you can connect an 43. DDS Units Setting external audio mixer between LineIn2 and Set work mode for HCS-XXXXDDS: LineOut;  Sync. Line Out1 Mixer: Adjust the audio parameters (Conference Management System - Setup - Audio Output Setup) of LineOut1 and the floor signal via Mixer 1 synchronously, see figure a).
  • Page 56 45. Alarm Setting 46. Chairman Unit Setting Enable the “ALARM” interface in the backside of System supports up to 100 chairman units, while all or HCS-8300M series congress unit. part chairman units have the chairman control facilities, so we can set the chairman unit (according to the order od unit’s ID) with control facilities or not through the submenu.
  • Page 57 Figure 2.1.11 Floor mode setting – Insert Mode Figure 2.1.12 Floor mode setting – Sync. Line Out1 Mixer Note: HCS-8300MAU/FS: supports cobranet protocol; HCS-8300MAD/FS/20: supports dante protocol.
  • Page 58 2.1.4.6 Operation Language Setting a). Press the “MENU” button to enter the rename interface; Select LCD display language from simplified Chinese, b). Press the “/” button to select character; Traditional Chinese, English. Other languages can be c). Press the “MENU” button to modify the character, added by the user through LCD_Designer tool.
  • Page 59: Configuration And Operation - Slave Mode

    2.1.4.13 Connecting to PC When connecting the CMU to the PC, its front panel will be locked and setup operation cannot be accessed, as shown as the following figure: 2.1.4.12 Power Management 2.1.5 Configuration and operation - slave mode Press and hold the “STANDBY” button to enter power management interface, as shown as the following When dual main unit hot spare or conference room figure:...
  • Page 60: Extension Main Unit

    2.2 Extension Main Unit 2.2.1 Functions and instructions Front panel Backside of HCS-8300ME/FS Backside of HCS-8300ME Figure 2.2.1 HCS-8300 series extension main unit Figure 2.2.1: 1. Overload indicator 6. Fiber output (with switch)  Normal: turn off;  Single-mode optical fiber, SC connector.
  • Page 61: Installation

    2.2.2 Installation The extension main unit (EMU) can be fixed in a standard 19-inch cabinet. The EMU is equipped with a pair of fixing brackets ①. First unscrew the lateral screws ② from the housing. Then fasten the brackets with these screws and put the EMU in the cabinet. Finally fix the four holes ③...
  • Page 62: Connection

    2.2.3 Connection HCS-8300 series CMU has two 6P-DIN output Each extension main unit has an extension input port interfaces; the power capacity of each 6P-DIN interface for connecting to extension interface of the congress is limited. If the actually needed power of the system...
  • Page 63: Extension Unit

    2.3 Extension Unit 2.3.1 Functions and instructions HCS-8300MES fully digital congress system extension unit Figure 2.3.1 HCS-8300 series extension unit Figure 2.3.1: 1. Power input 2. Power light (Red) 3. Extension input  Connecting to CMU or last HCS-8300MES. 4. Extension input indicator 5.
  • Page 64: Installation

    2.3.2 Installation The extension unit can be fixed on flat surface (table, wall, ground, etc). Make holes on flat surface according to the following figure, then fixed HCS-8300MES with M3 screws. Figure 2.3.2 Installation of the HCS-8300MES...
  • Page 65: Chapter 3 Congress Unit

    Chapter 3 Congress unit 3.1 Overview Congress unit is the common name to describe the HCS-8338NBC(-NP) chairman unit, Chinese panel units used by the attendees to contribute to a congress. HCS-8338NBCE(-NP) chairman unit, English panel The term includes discussion unit (chairman/delegate), HCS-8338NBD(-NP) delegate unit, Chinese panel voting unit, channel selector etc.
  • Page 66 HCS-8335AC(-NP) chairman unit conference functions, video conversation, video display, multiple delegate unit channel VOD and broadcasting, conference service, built-in HCS-8335AD(-NP) contactless IC-Card reader, internet access, built-in E-ink Economical Multimedia Congress Terminal (microphone array, nameplate (“-NP” as suffix only), printed nameplate for other 10"...
  • Page 67: Hcs-8315 Series Congress Unit

    3.2 HCS-8315 series congress unit 3.2.1 Functions and instructions Front panel of HCS-8313C chairman unit Front panel of HCS-8313D delegate unit Front panel of HCS-8314D delegate unit...
  • Page 68 Front panel of HCS-8315C chairman unit Front panel of HCS-8315D delegate unit Backside of HCS-8315 series congress unit Left side Figure 3.2.1 HCS-8315 series congress unit Figure 3.2.1: 1. Priority key with indicating light (for chairman 2. Microphone On/Off key with indicating light (for unit only): chairman unit) ...
  • Page 69 5. Multi functional keys with indicating light (5 7. Simultaneous interpretation channel number keys): display  In differente modes, the corresponding indicating 8. Microphone active indicator  When the microphone is activated, the indicator is light blink, and press the corresponding key to execute operation (refer to table 3.2.1 for details).
  • Page 70: Connection

    HCS-8315 series congress unit is equipped with a 1.5-meter long 6P-DIN cable with a standard male connector. To connect to the HCS-8300 CMU or the EMU, just connect the male connector of the first unit to the output of the main unit.
  • Page 71 3.2.2.3 External earphone An external earphone can be connected to the external earphone jack at the lateral side of the congress unit. Its volume can be adjusted by the earphone volume control button. The external earphone shall have a Ø 3.5 mm plug, as in the following figure: Functions and indications: Left stereo channel signal Right stereo channel signal...
  • Page 72: Operation

    3.2.3 Operation 3. Speaking (without software) Before a meeting starts, the congress units need to be configured by the operator, including: numbering and Speaking mode is configured on the CMU. (refer to testing. During the meeting, the participators use the section 2.1.4) congress unit to sign-in, activate microphone, request A.
  • Page 73 All other microphones cannot be activated unless 4. Voting (HCS-8315D does not have this function) one of the active microphones is turned off. Voting can be originated by TAIDEN Conference Management System (2 keys, 3 keys, 4 keys or 5 keys) D. “Apply” mode ...
  • Page 74 7. VIP unit  Any delegate unit can be assigned as a VIP unit by TAIDEN Conference Management System - at most 32 VIP units;  As long as the active microphone capacity is not full, the microphone of the VIP unit can be activated freely;...
  • Page 75 3.2.3.2 Chairman unit The chairman unit features all delegate unit functions, B. Turn off or mute delegate microphone additionally: Chairman can use the “Priority” key to execute “All 1. Priority mute” or “All off” operation.  If priority mode on the main unit is configured as “All mute”, all active delegate microphones (except 4.
  • Page 76: Hcs-8335 Series Economical Multimedia Terminal

    3.3 HCS-8335 series economical multimedia terminal 3.3.1 Functions and indications HCS-8335C chairman unit HCS-8335D delegate unit HCS-8335C-NP chairman unit HCS-8335D-NP delegate unit HCS-8335AC chairman unit HCS-8335AD delegate unit HCS-8335AC-NP chairman unit HCS-8335AD-NP delegate unit...
  • Page 77 HCS-8335(-NP) side HCS-8335(-NP) backside HCS-8335A(-NP) side HCS-8335A(-NP) backside Figure 3.3.1 HCS-8335 series economical multimedia terminal Figure 3.3.1:  Chairman unit: press this key to activate 1. Priority key with indicating light (for chairman unit only): microphone and indicating light;  According to priority mode configuration on main ...
  • Page 78 The volume is controlled via CMU or application 15. 0.6-meter 6P-DIN cable with standard plug software. (female x 1) 8. Contactless IC-card induction area 16. 1.5-meter 6P-DIN cable with standard plug 9. Microphone array (male x 1) 10. External microphone jack (Ø 3.5 mm) 17.
  • Page 79: Installation

    3.3.2 Installation Figure 3.3.2 Fixing of HCS-8335 series economical multimedia congress terminal Note:  The fixed installation of HCS-8335A series is the same as the installation of HCS-8335 series.
  • Page 80: Connection

    The HCS-8335 series economical multimedia terminal is equipped with a 1.5-meter 6P-DIN cable with a standard male connector. To connect to the HCS-8300 CMU or the HCS-8300 EMU, just connect the male connector of the first terminal to the output of the main unit.
  • Page 81 3.3.3.3 Video display The HCS-8335 series economical multimedia terminal is equipped with a 10” TFT LCD with 1280 × 800 high-resolution. It supports high definition digital video (SDI) display corresponding with standard CEA-861. Video signal transmitted on a high quality coaxial-cable, such as RG-6 or SYV-75 and the length of each cable is no more than 50 m.
  • Page 82: Operation

    3.3.4 Operation  IC-Card sign-in Before a meeting starts, the economical multimedia terminals need to be configured by the operator, In IC-Card sign-in status, “Please Use IC Card” will be including: numbering and testing. During the meeting, displayed on the LCD. Push the contactless IC card the participators use the multimedia terminal to sign-in, into the IC card slot or put the IC-card near the IC-card activate microphone, request to speak, vote, read...
  • Page 83 D. “Apply” mode 4. Voting a. Request to speak when the microphone On/Off Voting can be originated by TAIDEN conference key is pressed (default 6 microphones at most). management system software. The chairman unit can approve or reject his/her ...
  • Page 84 5. Channel selection  When the CMU is connected to interpreter unit(s), simultaneous interpretation function will work. To use the channel selector, an earphone must be plugged in. When the earphone is plugged, the LCD will display the simultaneous interpretation channel number language name.
  • Page 85 got a new message” will be displayed on its LCD and the indicating light of key “4”and “5” will blink. Press key “4” to read the corresponding message or press key “5” to ignore the message.  At most 4 messages can be stored in the congress unit.
  • Page 86 8. VIP unit  Any delegate unit can be assigned as a VIP unit by the TAIDEN conference management system software. At most 32 VIP units can be assigned;  As long as the active microphone capacity is not full, the microphone of the VIP unit can be activated freely;...
  • Page 87 3.3.4.2 Chairman unit 4. Voting The HCS-8335C chairman unit features all the functions of a delegate unit, and the following HCS-8335C chairman unit cannot originate voting additional functions: without a PC:  When controlled application software, 1. Priority nominative or ballot voting are available; ...
  • Page 88: Hcs-8336 Sdi Monitor

    3.4 HCS-8336 SDI monitor 3.4.1 Functions and indications Front Back and bottom Figure 3.4.1 HCS-8336 SDI monitor Figure 3.4.1: 1. Built-in Hi-Fi loudspeaker 5. 0.6-meter 6P-DIN cable with standard plug 2. 16:10 high resolution color wide-screen (female x 1) 3. Home key 6.
  • Page 89: Installation

    3.4.2 Installation Figure 3.4.2 Fixing of HCS-8336 SDI monitor...
  • Page 90: Connection

    The HCS-8336 SDI monitor is equipped with a 1.5-meter 6P-DIN cable with a standard male connector. To connect to the HCS-8300 CMU or the HCS-8300 EMU, just connect the male connector of the first unit to the output of the main unit.
  • Page 91: Operation

    Supports service function, and the service type name must be numbered when the system is used for the first can be edited by TAIDEN conference management time or when adding or replacing SDI monitors. The software. Press the “+” key or the “-” key to select numbering function can be activated by menu service and then press the “Menu”...
  • Page 92 Full, 16:9, and 4:3. the same booth is active;  When the booth number is 0, loudspeaker volume can be adjusted by the master volume control knob on the main unit or by TAIDEN conference management software...
  • Page 93 B. “About” Display the product information including unit ID, serial and version.
  • Page 94: Hcs-8338/8348 Series New Generation Paperless Multimedia Congress Terminal

    3.5 HCS-8338/8348 series new generation paperless multimedia congress terminal 3.5.1 Functions and instructions Front of HCS-8338ACE(-NP) Front of HCS-8338ADE(-NP) Front of HCS-8338BCE(-NP) Front of HCS-8338BDE(-NP) Front of HCS-8338NBCE(-NP) Front of HCS-8338NBDE(-NP) Side Bottom Figure 3.5.1a HCS-8338 series New Generation Paperless Multimedia Congress Terminal Front of HCS-8348ACE(-NP) Front of HCS-8348ADE(-NP)
  • Page 95 Front of HCS-8348BCE(-NP) Front of HCS-8348BDE(-NP) Front of HCS-8348NBCE(-NP) Front of HCS-8348NBDE(-NP) Side Bottom Figure 3.5.1b HCS-8348 series New Generation Paperless Multimedia Congress Terminal Front of HCS-8338NBCE/FM Front of HCS-8338NBDE/FM Front of HCS-8338BCE/FM Front of HCS-8338BDE/FM Bottom Figure 3.5.1c HCS-8338/FM series New Generation Paperless Multimedia Congress Terminal...
  • Page 96 Figure 3.5.1 1. Priority key with indicating light (for chairman Note: keys are avaliable when DCS software enables unit only): hard voting keys (Setup – System Parameters - -Topic  According to priority mode configuration on main and Voting -- Voting key) unit: 7.
  • Page 97: Installation

    3.5.2 Installation 3.5.2.1 Fixed installation of HCS-8338/8348 series Figure 3.5.2 Fixing of HCS-8338 series New Generation paperless multimedia congress terminal Note:  The fixed installation of HCS-8348 series is the same as the installation of HCS-8338 series.
  • Page 98 3.5.2.2 Flush-mounted installation of HCS-8338/FM series a. Cut a hole in the table according to the dimensions in figure 3.5.3; b. Put the terminal into the hole and drill four Ø 2 mm holes with 10 mm depth at the positions the fixing screws; c.
  • Page 99: Connection

    3.5.3.1 Connecting to 1000M Ethernet switcher 3.5.3.3 To external microphone HCS-8338/8348 series New Generation Paperless An external microphone is connected to the external Multimedia Congress Terminal is based on the TAIDEN microphone jack at the lateral side of the multimedia originated GMC-STREAM...
  • Page 100: Operation

    Icons and fonts on primary interface can be defined by to be configured by the operator, including: numbering user through “Taiden Update Manager” tool, details and testing. During the meeting, the participators use refer to the user manual of “Taiden Update Manager” multimedia terminals sign-in, activate tool.
  • Page 101 B. “OVERRIDE” mode Note:  Active microphone number limitation (1/2/3/4)  When numbering, please number the multimedia NOT reached: terminals one by one and do NOT press When the microphone On/Off button on the “number” key of several terminals at the same front panel is pressed, the speaker can give time.
  • Page 102 SI/Lecture/Multimedia/Browser/Message/ displayed on large screen(s). Camera can be operated independently;  Service can be operated under the supporting of TAIDEN Conference Management System;  Mic./Intercom/Voting/Paperless/VOD/Sharing/ Network can be operated under the supporting of TAIDEN Conference Management System and File Server.
  • Page 103 1. Microphone 2. Intercom Click the “Intercom” icon to go to the intercom interface, Including “Mic. List”, “Layout” and “Setting”. including “Text Chat” and “Video Chat”: A. “Mic. List” A. Text Chat Delegates (including chairman unit, delegate unit, VIP The text exchange interface is shown in the following unit and ambient microphone) are listed as in the figure;...
  • Page 104 B. Video Chat 3. Vote Click the “Intercom” icon and the following interface appears. Double click on the delegate whom you want to contact and request for a video dialog (The earphone must have been inserted; otherwise it will Including “Sign-in”, “Vote” and “Proposal”. prompt “Please insert headphone first”).
  • Page 105 Push the IC-card into the slot on the right side of the Input PIN code through virtual keyboard to sign in. If terminal, if sign-in was successful; the figure is shown the PIN code is wrong, "Invalid PIN code" will be as below.
  • Page 106  Finger Print and PIN Code Sign-in In finger print and PIN code sign-in status, the LCD will display as in the following figure: B. Voting Chairman unit can start 3 keys voting, application Either finger print sign-in or PIN code sign-in will work. software can start 2 keys, 3 keys, 4 keys or 5 keys voting.
  • Page 107  HCS-8338/8348 series New Generation Paperless  Display name list Multimedia Congress Terminals support voting For open mode proposal, when click “Name List” on with photo. When the delegate votes, it will take a multimedia terminal with voting control option or click picture and upload the delegate's picture as well “Name List”...
  • Page 108 language; B. List  If the earphone is unplugged, the unit will return to In the lecture list, double click on the lecture to open floor language automatically; and read the lecture. Supports Internal Storage,  Earphone volumes are adjustable by the “Volume” Storage Card and Flash Disk.
  • Page 109 A. Multimedia - Photos C. Multimedia - Camera You can click "Photos" folder icon to browse pictures, Click the “Camera” icon or the “Camera” item in the supports jpg, bmp, png and gif formats now. When navigation menu to go to the camera control interface. viewing picture, you can swipe your finger acrooss the The delegate can take photo via the built-in camera screen to switch pictures;...
  • Page 110 Different access authorizations can be set in the file Click on a service icon to request for the corresponding server. Delegate, chairman and VIP have differing service. If the icon turns blue, the service information rights to browse different files. For example: a delegate will be send to the server and the information will be can browse public files and the files in the delegate displayed on the application software.
  • Page 111  When controlled by PC, the operator can send a message to any congress unit;  Click “Preview” and “Next” to read all messages;  When receiving a message, “You have a got a new message!” will be displayed on the LCD. Click “Read”...
  • Page 112 If the request is approved, the desktop of the To prompt the setup interface, please connect the delegate will be shared with all other delegates and multimedia terminals TAIDEN conference with the large display screen. management software, and then select “Setup” – “Multimedia Terminal” – “Switch Interface”.
  • Page 113 C. Language Select the operation language. D. Brightness Setup the brightness of the LCD screen. 16. Snapshot Press “Home” and “YES” key at the same time to shot screen at any time. The picture (*.jpg file) was saved in the “snapshot” file and can be viewed through multimedia function.
  • Page 114 3.5.4.2 Chairman unit The chairman features all functions a delegate has, When his/her request is approved, he/she can speak additionally: and the last activated microphone will be turn off at the same time. 1. Priority  If priority mode is configured as “All mute”, all B.
  • Page 115 d. Click the “End” button to finish voting. Voting result will be displayed on LCD (for open voting only) in list, bar, or pie.
  • Page 116 Volume: adjust built-in loudspeaker Note: “Conference volume of all congress units, line output volume  The TAIDEN Management and group output volume, range: -30 dB - 0 dB; System” application software offers  Active Microphones: active microphone number possibility to select a PARLIAMENT mode 1/2/3/4;...
  • Page 117  Approve: approve the request/response of a Under Discussion and Parliament modes, a dialog window was poped up, shown as in the following selected microphone and turn on the microphone;  Reject: reject the request/response of a selected figure. Press and hold to drag it to any position, press the “...
  • Page 118  Restart Sign-in: clear current sign-in result and restart sign-in;  Stop Sign-in: stop sign-in;  Sign-in Result: display sign-in result; d. Select proposal:  Click “Proposal” to browse all proposals in the current meeting (red coclor stands that the proposal has signed in), and click to select a proposal from a proposal list;...
  • Page 119 sharing, prompting information will be displayed at the bottom of the control unit LCD. Click the "Read" button to check or click the "Ignore" button to ignore it.  Start Sharing: if the sharing control unit clicks this button, the content on the unit will be displayed on all multimedia units immediately;...
  • Page 120: Chapter 4 Interpreter Unit

    Chapter 4 Interpreter unit Simultaneous interpretation function of HCS-8300 Product type: PMCS is designed for the requirements of large scale HCS-4385U/50 Interpreter unit multilingual international congresses: it can provide up Fully Digital Congress System Interpreter Unit (64 CHs, IC-Card, to 64 language channels (64 CHs).
  • Page 121: Hcs-4385U/50

    4.1 HCS-4385U/50 4.1.1 Functions and indications Front Side Bottom Figure 4.1.1 HCS-4385U/50 Interpreter unit...
  • Page 122  Listening area: 10. Output channel A/B/C switch with indicating lights Loudspeaker/earphone control:  Switch to preset the output channel 1. Built-in Hi-Fi loudspeaker 11. Microphone mute key (MUTE)  When the microphones of all interpreter units in the  Push and hold the Mute button to temporarily booth disabled, listen...
  • Page 123 21. Beep button ( )  You can disable and enable the beeps of the interpreter unit with the Beep button. When beeps are enabled, the display shows a musical note. The interpreter unit can generate beeps for notification of special events to support blind interpreters on the headphones.
  • Page 124: Installation

    4.1.2 Installation HCS-4385U/50 interpreter unit is available as tabletop or e. Put the interpreter unit into the recess until the as flush-mounted version. circumferential supporting edge fits with For flush-mounting: table-top surface. Fix it with screws from the bottom. a. Make a recess in the table according to the The length of the screws depends on the thickness dimensions in figure 4.2.1;...
  • Page 125: Connection

    CMU with a CBL6PP extension cable (the cable features a 6P-DIN male connector at each end). In HCS-8300 Paperless Multimedia Congress System, only the congress main unit can realize a “Closed Loop - Daisy Chain”...
  • Page 126 4.1.3.3 External earphone An external earphone can be connected to the external earphone jack at the lateral side of the Interpreter unit. Its volume can be adjusted by the earphone volume control knob. The external earphone shall have a Ø 3.5 mm plug or a Ø...
  • Page 127: Setup

    4.1.4 Setup To realize the simultaneous interpretation function, the Example: interpreter unit should be incorporated in the congress Booth 1 is for translation between English/Chinese. system and they should be setup before the meeting. Output channel A is English, output channel B is Chinese, Any operating status of the interpreter unit will be and output channel C is “None”.
  • Page 128 Figure 4.1.6 Direct interpretation Figure 4.1.7 Relay interpretation Figure 4.1.8 Schematic diagram of the connection of interpreter units...
  • Page 129 4.1.4.2 LCD configuration menu When the “Interpretation setup” has been configured in Step 12: Select to display speaking time or not; the CMU, and then the interpreter unit must be Step 13: Finish. configured:  If the interpreter unit has not been configured, the Step 1: Setup operation language LCD will display “UNIT NOT INSTALLED”;...
  • Page 130 Step 4 to 8: Select monitor channel language Step 11: Select to activate the “Auto Floor” function or not Preset 5 most familiar languages as monitor channel. If the selected input language is the same as the output language and if the “Auto Floor” function is activated, the interpreter unit will switch the input channel to floor language automatically.
  • Page 131 4.1.4.3 Other configuration 4.1.4.3.1 Output channel configuration 4.1.4.3.2 Interlock mode To distribute the interpretation languages separately, Interpretation mode can be setup by menu operation A/B/C channels are provided in the interpreter unit. on the main unit (refer to section 2.1.4.2): When the interpreter unit menu configuration is finished, ...
  • Page 132: Operation

    4.1.5 Operation loudspeaker of every interpreter unit in this booth will 4.1.5.1 Number mute automatically. Now the interpreter can listen with the earphone and adjust the volume, treble and First of all, make sure that the interpreter units are bass with the “Earphone volume control knob” ⑤, connected properly to the CMU.
  • Page 133 4.1.5.3 Operation of speaking area The speaking area, on the right side of the unit, is the 8. Beeps area which is used to distribute the interpretation The audio beeps can be toggled on and off with the languages to the corresponding channels. It includes Beep button.
  • Page 134: Hcs-8385

    4.2 HCS-8385 4.2.1 Functions and indications Front Side Bottom Figure 4.2.1 HCS-8385 Interpreter unit...
  • Page 135  Listening area: the interpretation channel;  When the Output channel B/C switch button (B C) Loudspeaker/earphone control: was pressed, push the function knob to go to 1. Loudspeaker volume control knob channel 1, turn the function knob to select the output 2.
  • Page 136  14. Message key( Interface:  If selected “Allow Send Message” by application 3. TRRS jack (Ø 3.5 mm) software (Control – Booth Manage. – Param. 21. Stem microphone socket Setup), when unread message exist, this 22. USB socket indicating light will be activated, press this button 23.
  • Page 137: Connection

    To obtain “daisy-chain” ring connection just connect the last congress unit back to the CMU with a CBL6PP extension cable (the cable features a 6P-DIN male connector at each end). In HCS-8300 Paperless Figure 4.2.4 “Daisy-chain” connection between HCS-8385 Multimedia Congress System, only the congress main Interpreter units unit can realize a “Closed Loop - Daisy Chain”...
  • Page 138 Functions and indications: Left stereo channel signal Right stereo channel signal Power ground/Shield 4.2.2.4 External microphone An external headset can be connected to the TRRS jack at the lateral side of the Interpreter unit. The external headset shall have a Ø 3.5 mm plug, as in the following figure: Functions and indications: Left stereo channel signal...
  • Page 139: Setup

    4.2.3 Setup To realize the simultaneous interpretation function, the Example: interpreter unit should be incorporated in the congress Booth 1 is for translation between English/Chinese. system and they should be setup before the meeting. Output channel A is English, output channel B is Chinese, Any operating status of the interpreter unit will be and output channel C is “None”.
  • Page 140 Figure 4.2.5 Direct interpretation Figure 4.2.6 Relay interpretation Figure 4.2.7 Schematic diagram of the connection of interpreter units...
  • Page 141 Under the standby interface, press the If you select App, press the Function button to open QR “Home” button to enter the LCD menu. code interface, scan the QR code according to you phone or pad to download Taiden SI tool App. After...
  • Page 142  installation, you can send message to all or part booths Compressor via Bluetooth. On or Off compressor. Setting 1). Select On/Off by rotating the Function knob, default is On, when strong signal inputs, the distortion will Input Pincode first before enter setting interface, be controlled well;...
  • Page 143 4.2.3.3 Other configuration 4.2.3.3.1 Input channel configuration 4.2.3.3.3 Interlock mode The HCS-8385 equipped with 7 pre-select buttons Interpretation mode can be setup by menu operation (1/2/3/4/5/6/7) for relay languages with activation on the main unit (refer to section 2.1.4.2): indication on the LCD. When the monitor channel Interlock mode between booths:...
  • Page 144: Operation

    4.2.4 Operation 6. Quality indication: The second line of the display 4.2.4.1 Operation of listening area shows the qualities of the interpretations on the channels that are assigned to the pre-select buttons The listening area, on the left side of the unit, is the of the interpreter unit.
  • Page 145 4.2.4.2 Operation of speaking area The speaking area, on the right side of the unit, is the 8. Beeps area which is used to distribute the interpretation The audio beeps can be toggled on and off with the languages to the corresponding channels. It includes Beep button.
  • Page 146: Hcs-8385Hdmi

    2. HDMI output2 5. SDI input 3. Mini 6P-DIN socket 6. SDI loop output  Connection HCS-8385 TAIDEN 7. Ground generation simultaneous interpreter unit through 8. Power indicator cable with mini 6pin DIN plug on each end; 9. Power socket ...
  • Page 147 HCS-8385 integrated video monitor control function, connected to third party HDMI monitors via HCS-8385HDMI, up to 8 video sources selection can be made from the Interpreter Unit. Figure 4.2.9 New Generation Simultaneous Interpretation System...
  • Page 148: Chapter 5 System Connection And Basic Setup Procedure

     The added up cable lengths between a main meeting flexibly. unit and the most remote congress unit must In this chapter, the connections of HCS-8300 PMCS are not exceed 250 m; introduced by diagrams and examples.  The length of an individual extension cable must not exceed 80 meters.
  • Page 149 Table 5.1.1 Quick lookup table of HCS-8300M CMU/EMU load capability (each outlet) The extension cable length between the CMU(EMU) and the first Congress Unit connected to the socket Type Type No. 80 m + 80 m + HCS-4352T/50 20 m 40 m 60 m 80 m...
  • Page 150 Table 5.1.2 Quick lookup table of HCS-8300MES load capability (each outlet) The extension cable length between the HCS-8300MES and the first Congress Unit Type Type No. connected to the socket 20 m 40 m 60 m 80 m HCS-48U7/U8/U9/U10/ Equipped with Electronic Nameplate, speaker and microphone 4886+HCS-1080 Equipped with 7.2”...
  • Page 151 Table 5.1.3 Quick lookup table of HCS-8300PM/PM2 load capability (each outlet) The extension cable length between the HCS-8300PM/PM2 and the first Multimedia Terminal Multimedia connected to the socket Terminal 100m HCS-8338 HCS-8348 HCS-8338/FM HCS-8338-NP HCS-8348-NP Table 5.1.4 Quick lookup table of HCS-8300MX/FS load capability (each outlet) The extension cable length between the HCS-8300MX/FS and the first Interpreter Unit connected to the socket Type...
  • Page 152: Connection Between The Cmu/Emu And The Contribution Units

    1 unit. Proceed one by cable. For the connection between congress terminals, one in a series configuration.The backbone of HCS-8300 just connect the free “1000M Ethernet” interfaces of the system is formed (as shown in figure 5.1.1).
  • Page 153: Connection Between Hcs-8300 Pmcs And Automatic Video Tracking System

    5.1.3 Connection between HCS-8300 PMCS and automatic video tracking system HCS-8300 PMCS can be connected to an automatic compatible with several kinds of video signals and video tracking system. For video tracking purposes, the operates automatic video switching. The video tracking...
  • Page 154: Connection Between Hcs-8300 Pmcs And Digital Infrared Language Distribution System

    5.1.4 Connection between HCS-8300 PMCS and digital infrared language distribution system  By connecting to HCS-5100 digital infrared language CMU connecting to digital infrared language distribution system, the audio signal of the HCS-8300M distribution system via HCS-5100MC/N CMU can be converted into an infrared signal and The HCS-5100MC/N transmitter does not have a digital transmitted.
  • Page 155 Figure 5.1.3 Congress main unit connecting to digital infrared language distribution system via HCS-5100MA/FS/N Figure 5.1.4 Congress main unit connecting to digital infrared language distribution system via HCS-5100MC/N...
  • Page 156: Connection Between Hcs-8300 Pmcs And Central Control System

    5.1.5 Connection between HCS-8300 PMCS and central control system TAIDEN intelligent central control system is an advanced through LAN or internet. TAIDEN HCS-6100 intelligent central control system and comprehensive control system. It can link together TAIDEN HCS-8300 PMCS can be joined together various devices, hardware and environment equipment from different manufacturers.
  • Page 157: Connection Between Hcs-8300 Pmcs And Conference Sign-In System

    5.1.6 Connection between HCS-8300 PMCS and Conference Sign-in System Conference Sign-in System (CSS, untouched) aims at (user can choose as needed), meanwhile, personalized providing the reliable, effective and convenient congress portrait and design can be printed onto the surface of the sign-in solution for various large congress.
  • Page 158: Combine/Split Congress Rooms Easily

    5.1.7 Combine/split congress rooms easily HCS-8300 series Paperless Multimedia Congress System supports a combining/separating function for multiple meeting rooms Using Cat.5 cable, several meeting rooms can be combined/separated at will through the HCS-8300MX Congress Room Combiner. Advantage: one HCS-8300MX can combine up to 8 meeting rooms controlled by a Central Control System.
  • Page 159 Several meeting rooms using capacitor microphones can be combined or separated through HCS-8300M Fully Digital Congress System Main Unit, HCS-8300MI Audio Input Interface and HCS-8300MO Audio Output Device. Advantage: several meeting rooms can share one main unit to reduce costs. Disadvantage: the microphones are star connected, the system is complex and difficult to manage, and only discussion feature can be realized - no conference sign-in, voting, simultaneous interpretation, video tracking, intercom, etc.
  • Page 160: Interpreter Booth Combination & Split

    5.1.8 Interpreter booth combination & split Cooperating with HCS-8300MX/FS, at most 24 rooms can be merged and their booths can be shared. Figure 5.1.10 Diagram for interpreter booth combination & split...
  • Page 161: Connection To Remote Interpretation

    5.1.9 Connection to remote interpretation In conjunction with a HCS-8300MI/MO and a telephone coupler, cost-saving remote interpretation function can be realized. Figure 5.1.11 Remote interpretation...
  • Page 162: Basic Configuration Of Congress System

    HCS-8313 discussion units (including chairman unit and delegate units) and several HCS-4342N/50 channel selectors (connected to the system via a HCS-4340B/50 multi-function connector). The connection diagram is shown in the following figure: Figure 5.2.1 Connection example of HCS-8300 PMCS...
  • Page 163 According to the requirements of the specific case in this c) Preset monitoring channel. Channel a, b, c are set section, the configuration is as the following: as 1-Chinese, 2-English and 3-French respectively. 1. Configuration CMU 3. Configurate Interpreter units in booth 2 (the a) Active microphone number limitation: active configuration of both Interpreter units is the same) microphone number limitation limited to 2 implies...
  • Page 164: Chapter 6 Peripherals And Accessories

    Chapter 6 Peripherals and accessories 6.1 HCS-8300MO Series HCS-8300MO Series 8 Channels Audio Output Device b) Output level of each channel adjustable; a) Converts the digital audio signals of the c) Configurable as Sync/Not sync power on/off congress system multi channel with congress main unit.
  • Page 165 6.1.1.2 Rear panel Rear panel of HCS-8300MOD/FS Rear panel of HCS-8300MOD/FSD Rear panel of HCS-8300MOD Rear panel of HCS-8300MOA/FS...
  • Page 166 Rear panel of HCS-8300MOA/FSD Rear panel of HCS-8300MOA Figure 6.1.2 Rear panel of HCS-8300MO Series 8 Channels Audio Output Device Figure 6.1.2: 13. 8x RCA outlet 21. Power input  Unbalanced analog audio outputs. 22. Power switch 14. 8x 3-cord phoenix connector 23.
  • Page 167: Connection

    HCS-8300M CMU in three ways (only one of them can be used at one time): ♦ Connect the "EXTENSION" interface of the HCS-8300 CMU to the "EXTENSION IN" interface of the HCS-8300MO with a Cat. 5 cable. ♦ Connect one outlet (6P-DIN) of the HCS-8300 CMU to the "DELEGATE IN"...
  • Page 168 Figure 6.1.3 CMU connecting to infrared language distribution system via HCS-8300MO...
  • Page 169: Configuration And Operation

    6.1.3 Configuration and operation  The third row displays the CobraNet receiving port When installation and connection are finished and prior to the meeting, HCS-8300MO 8 Channels Audio Output number and name of the corresponding equipment; Device should be configured by front panel menu b2.
  • Page 170 The current chosen term is highlighted. d). Press the “/” button to adjust the CobraNet  Press the “/” button to switch between menu receiving port between 256-511; items;  Press the “MENU” button to go to selected menu item; ...
  • Page 171 c). Press the “MENU” button to save and return to the a). Press the “/” button to select “Yes” or “No”; upper level menu. b). Press the “MENU” to save and return to the upper level menu. 6.1.3.4 Power mode setting 6.1.3.7 Machine Rename The power mode of HCS-8300MO Series 8 Channels Audio Output Device includes:...
  • Page 172 6.1.3.9 About Dante The display of Dante module information, includes: dante version, device version and device name. Press any button to return to the upper level menu.
  • Page 173: Hcs-8300Mi Series

    6.2 HCS-8300MI Series HCS-8300MI Series 8 Channels Audio Input Interface b) All inputs can be mixed with arbitrary ratio, and a) Transmits 8 digital(AES/EBU)/analog audio channels outputted to any channel; to the interpretation channels of the Congress c) Configurable as Sync/Not sync power on/off with System, for example for remote interpretation congress main unit.
  • Page 174 6.2.1.2 Real panel Real panel of HCS-8300MID/FS Real panel of HCS-8300MID/FSD Real panel of HCS-8300MID Real panel of HCS-8300MIA/FS...
  • Page 175 Real panel of HCS-8300MIA/FSD Real panel of HCS-8300MIA Figure 6.2.2 Real panel of HCS-8300MI Series 8 Channels Audio Input Interface Figure 6.2.2: 13. 8x RCA input 21. Power input  Unbalanced line-in inputs. 22. Power switch 14. 8x 3-cord phoenix connector 23.
  • Page 176: Connection

    6.2.2 Connection To realize a multi-channel digital audio transmission solution, HCS-8300MI and HCS-8300MO are combined according to Figure 6.2.3. Figure 6.2.3 HCS-8300MI+HCS-8300MO multi-channel digital audio transmission solution...
  • Page 177: Configuration And Operation

    6.2.3 Configuration and operation  The third row displays the unit ID and the output When installation and connection are finished, and prior to the meeting, HCS-8300MI Series 8 Channels dynamic level of mix audio. Press the “EXIT” Audio Input Interface should be configured by front button to “ON”/“OFF”...
  • Page 178 ■  If “CobraTrans mode” is selected, then go to step Adjust monitoring volume  The monitoring channel volume can be adjusted between -30 dB - 0 dB. b). Press the “/” button to adjust the CobraNet Tx bundle between 256-511; c).
  • Page 179  If working mode is set as “CobraTrans” / B. Select audio input mode “DanteTrans” mode and audio type is set as “Analog” / “Digital”, configuration is finished. Return to the upper level menu; a). Press the “/” button to select audio input mode F1.
  • Page 180 6.2.3.5 Operation language setting Setup operation language. Currently, simplified Chinese, traditional Chinese and English are supported. Other languages can be added by user through the LCD_Designer tools. Operation step: 6.2.3.8 About Dante The display of Dante module information, includes: dante version, device version and device name. Press any button to return to the upper level menu.
  • Page 181: Hcs-8300Mx

    6.3 HCS-8300MX To combine/split meeting rooms at leisure. 6.3.1 Functions and instructions Front panel Backside Figure 6.3.1 Congress Room Combiner HCS-8300MX Figure 6.3.1: 1. Power switch 7. 8x RJ45 port  Connecting to the CMU to split/combine several 2. LCD ...
  • Page 182: Connection

    6.3.2 Connection Several meeting rooms can be split/combined at leisure through the Congress Room Combiner HCS-8300MX with Cat.5 cable. One HCS-8300MX can combine up to eight meeting rooms. The system can be controlled easily by a central control system. Figure 6.3.2 Splitting/Combining several meeting rooms with the Congress Room Combiner HCS-8300MX...
  • Page 183: Configuration And Operation

    6.3.3 Configuration and operation When installation and connection are finished and prior 6.3.3.1 Port to the meeting the Congress Room Combiner HCS-8300MX should be configured by front panel menu operation. A) Initialization a). Press the “/” button to switch port number between 1-8;...
  • Page 184 6.3.3.3 About Displays the system information of the Congress Room Combiner HCS-8300MX. It includes: software version, corporation information and series number. Press any button to return to upper level menu.
  • Page 185: Hcs-8300Mx/Fs

    6.4 HCS-8300MX/FS HCS-8300MX/FS has one MAIN UNIT interface, eight SI BOOTH interfaces, one set of fiber (FIBER) interface ETHERNET interface. Simultaneous interpretation function is realized in only one room under idle mode; cooperating with HCS-8302MX/FS - the General Controller for Booth Combiners - booths can be shared and rooms can be merged and splitted.
  • Page 186 10. Interpreter units interfaces (1-8, eight routes) 11. Fiber interface  Single-mode optical fiber, SC connector;  Connecting to the HCS-8302MX/FS. 12. RJ45 interface(ETHERNET) 13. Power input 14. RS-232C-TEST  The “TEST” port is used for updating and monitoring. 15. Mini USB port ...
  • Page 187: Connection

    6.4.2 Connection With HCS-8300MX/FS Booth Combiner, simultaneous interpretation is realized in only one room under idle mode; in cooperation with HCS-8302MX/FS - the General Controller for Booth Combiners - booths can be shared and rooms can be merged and splitted via RoomBoothCombine software configuration without changing cable connections.
  • Page 188: Configuration And Operation

    6.4.3 Configuration and operation When installation and connection are finished, the Note: Booth Combiner HCS-8300MX/FS should  One HCS-8300MX/FS can lend its booths to configured by the front panel menu operation or the only one HCS-8300MX/FS, and not to several RoomBoothCombine software prior to the meeting.
  • Page 189 C) Access main menu Pressing the “MENU” button under initial user interface d). Press the “MENU” button to save at each will go to the main menu, which includes eight character; submenu items: e). Press the “EXIT” button to return to the upper level “Machine Rename”...
  • Page 190  If connect one HCS-8300MX/FS: the conference Operation step: room function should be set as “All Function”;  If connect two HCS-8300MX/FS: they must have the same conference Room ID, and one of the conference room function should be set as “All a).
  • Page 191 6.4.3.8 About Displays the system information of the Booth Combiner HCS-8300MX/FS. includes: software version, corporation information and series number. Press any button to return to the upper level menu.
  • Page 192: Hcs-8302Mx/Fs

    6.5 HCS-8302MX/FS HCS-8302MX/FS - the General Controller for Booth Combiners - has at most twenty-four fiber interfaces. Cable connections do not need to be changed. In cooperation with HCS-8300MX/FS, at most twenty-four rooms can be merged and their booths can be shared. 6.5.1 Functions and instructions Front panel of General Controller for Booth Combiners HCS-8302MX/FS Rear panel of General Controller for Booth Combiners HCS-8302MX/FS...
  • Page 193 13. A type USB interface  Connecting to USB disk. 14. “ETHERNET” interface 15. RS-232 communication interface  The "COM" port is used for connecting to a central control system for central controlling, as well as for system diagnosis. 16. Power input 17.
  • Page 194: Connection

    6.5.2 Connection Several conference rooms can be merged and splitted and their booths can be shared via the HCS-8302MX/FS General Controller for Booth Combiners with its fiber interfaces. One HCS-8302MX/FS can control at most twenty-four conference rooms and their booths. Controlling is very simple through “RoomBoothCombine” software operation. Figure 6.5.2a Merge and split several booths via the HCS-8302MX/FS General Controller for Booth Combiners and the HCS-8300MX/FS...
  • Page 195 Figure 6.5.2b Merge and split several booths via the HCS-8302MX/FS General Controller for Booth Combiners and the HCS-5100MA/FS/N...
  • Page 196: Configuration And Operation

    6.5.3 Configuration and operation When installation and connection are finished, the HCS-8302MX/FS General Controller Booth Combiners should be configured by front panel menu Press the “EXIT” button to return to the upper level operation or the “RoomBoothCombine” software before menu after setting finished. the meeting.
  • Page 197 3. About Press the “←/→” button to select room function Displays system information between All Function and Only Landlord; HCS-8302MX/FS General Controller Booth Combiners. It includes: software version and series Press the “MENU” button to save the change. number. Press any button of "Menu"/ "Exit"/ “←"/ "→” to return to the upper level menu.
  • Page 198 ♦ Split HCS-5100MAF To split the merged HCS-5100MAF, just change the Master Mode to Idle Mode. Steps: a. Press the number keys 2 on the front panel; b. Press the “→” button to go to mode setup interface, and press the “MENU” button to enter; c.
  • Page 199: Hcs-8300Kmx

    6.6 HCS-8300KMX HCS-8300KMX is designed based on the Gigabit Multimedia Congress Stream technology, and is used to connect the congress main unit, the HCS-8338 and HCS-8348 series Paperless Multimedia Congress Terminals, the video server, external Ethernet switches, etc. 6.6.1 Functions and instructions Front panel Rear panel Figure 6.6.1 HCS-8300kMX Congress Gigabit Network Switcher...
  • Page 200: Hcs-8300Pm/Pm2

    6.7 HCS-8300PM/PM2 HCS-8300PM Power Supply Unit congress main unit. HCS-8300PM2 Dual Backup Power Supply Unit The HCS-8300PM2 has two completely independent power supply systems built-in to realize dual backup for The HCS-8300PM/PM2 supplies power to the HCS-8338 system power supply. If the primary power supply fails, and HCS-8348 series Paperless Multimedia Congress the standby power takes over supply immediately.
  • Page 201: Connection

    Figure 6.7.1: 1. Power A indicating light 9. 6P-DIN interface (OUT)  For extension. 2. Power B indicating light 3. Power A input 10. Fault indicating light 4. Power A switch 11. Power B switch 5. Fault indicating light 12. Power B input 6.
  • Page 202: Hcs-8319

    6.8 HCS-8319 HCS-8319 Service Request Control Unit is equipped with a 10" LCD touch panel. In cooperation with the service request function of the HCS-8338 and HCS-8348 series Paperless Multimedia Congress Terminal, it displays seat information and service request on the LCD and enables response to the request.
  • Page 203: Operation

    6.8.3 Operation 6.8.3.1 System startup 6.8.3.2 Function operation After connection of the power supply to the touch panel, 1.Service request and response press the power button at the right side of the touch When a delegate requests a service, its seat will be panel to start the touch panel.
  • Page 204 2.Setup C. Password Setup password. After connection of the power supply to the touch panel, press power button at the right side of the touch panel to start touch panel; press power button again to close touch panel. When touch panel on, hold pressing power button for 6 seconds, system setup interface will prompt.
  • Page 205 After calibration, click any position on the touch screen to save calibration and return; if no operation is executed, it will return automatically after 30 seconds.
  • Page 206: Hcs-8301 Series Digital Audio Mixer

    6.9 HCS-8301 series digital audio mixer The HCS-8301 Series Digital Audio Mixer for inputs, the AES/line output and the simultaneous Conference cooperating with the HCS-8300MAU/FS or interpretation without a PC. The status of every HCS-8300MAD/FS/20, the operator can adjust and channel can be displayed on the 10"...
  • Page 207 Figure 6.9.1: 1. LCD touch panel  Displays current configuration, connection status of the HCS-8301 series digital audio mixer;  Setup machine information (such as IP address) and display of SI channels. 2. Gain adjusting knob of active microphone 1…6, AES/LINE IN1 and AES/LINE IN2 ...
  • Page 208 6.9.1.2 Rear panel Figure 6.9.2 Rear panel of the HCS-8301 Series Digital Audio Mixer for Conference Figure 6.9.2: 1. Power switch 8. Ethernet interface 2. Power input 9. CobraNet interface (HCS-8301M)  Connecting to the “COBRANET” interface of the 3. Ground pole 4.
  • Page 209 6.9.1.3 Side view Figure 6.9.3 Side view of the HCS-8301 Series Digital Audio Mixer for Conference Figure 6.9.3: 1. SD card socket  For system upgrading 2. A type USB interface  Reserved...
  • Page 210: Connection

    6.9.2 Connection Figure 6.9.4 Connection between the HCS-8301M and the HCS-8300MAU/FS...
  • Page 211: Configuration And Operation

    6.9.3 Configuration and operation After installation, power on the HCS-8301 series digital audio mixer, initialization interface will show as in the ” Click the “ button to enter configuration interface: following figure:  Machine Name After initialization, it will display current status, as in the Input machine name through the virtual keyboard.
  • Page 212 After calibration, click any place of the touch screen to save current setting and return to configuration interface. If there is no operation within 30 seconds after calibration, it will return to configuration interface automatically.  Motor speed Adjust the motor speed by pressing the “ ”...
  • Page 213: Microphone

    6.10 Microphone  Removable stem microphone Detaching of the M-model windshield Functions and instructions: a. Prepare a straight screwdriver; 1. Electret condenser cardioid microphone b. Insert the straight screwdriver into the gap of the 2. Two-color microphone on/off LED ring microphone and press the straight screwdriver.
  • Page 214: Earphone

    6.11 Earphone  The jack plug of the stereo headphone can be inserted EP-960AH Interpreter headset into a Ø 3.5 mm stereo headphone jack socket. Applicable types include:  EP-820AS Single earphone  EP-960BH Interpreter headphone (stereo)  EP-829 Single earphone ...
  • Page 215: Accessories

    6.12 Accessories Some dedicated accessories are involved in the CBL6PP-02 dedicated 6-pin extension cable connection of conference system devices. Herein, these CBL6PP-02CMP dedicated 6-pin extension cable  Male connector at both ends accessories are introduced, including:  Length: 2 m ...
  • Page 216 Detachable 4P-DIN Standard Plug  For soldering to 4P-DIN cable  Removable DIN standard male connector (4PIN) CBL4PK-01 power adapter cable CBL4PK-01CMP power adapter cable  ①. 2P aviation socket (female) 10. Solderable 4P-DIN Standard Socket  ②. 4P-DIN socket (female) ...
  • Page 217 13. Cat.5 network cable  Connecting the CMU and the PC  Ethernet crossover cable with RJ45 connector at both ends  Length: 3 m 17. MIC-SK-H stem microphone fixing base (suspension)  Suspension fix 5P E type stem microphone ...
  • Page 218: Chapter 7 Working Environment And Maintenance

    7.1 Public areas It is recommended to meet the following conditions for In public areas ensure that the cables attached to the technical rooms where HCS-8300 central control system units, including extension cables, are run and laid equipment is housed: ...
  • Page 219: System Operator Room

     In the hall, booths should be set up at the back or sideways.  Booths should be elevated to provide an overall, unobstructured direct view of the chairman, the speakers and any other relevant visual aids.  A window should be installed at the forefront of the booth across the overall length.
  • Page 220: Chapter 8 Technical Specifications

    Chapter 8 Technical specifications 8.1 System specifications System performance Conforms to IEC 60914, the international standard for congress systems System environmental conditions Working conditions fixed/stationary/transportable Temperature range: - Transport: -40 °C to +70 °C - Operating: 0 °C to +45 °C Max.
  • Page 221: Congress System Main Unit

    8.2 Congress system main unit 8.2.1 Congress main unit Physical characteristics 8.2.1.1 Types HCS-8300MAU/FS HCS-8300MAD/FS/20 HCS-8300MB(/20) Installation Tabletop / standard 19-inch rackmount Dimensions (mm) Color White (PANTONE 420 C) 7.8 kg Weight Electrical characteristics 8.2.1.2 Types HCS-8300MAU/FS HCS-8300MAD/FS/20 HCS-8300MB(/20) ≤4096 Microphone capacity Channels 64 CHs...
  • Page 222: Extension Main Unit

    8.2.2 Extension main unit 8.2.2.1 Physical characteristics Types HCS-8300ME(/FS) Installation Tabletop / standard 19-inch rackmount Dimensions (mm) Color White (PANTONE 420 C) Weight 10.0 kg 8.2.2.2 Electrical characteristics Types HCS-8300ME(/FS) America, Japan: AC 100 V - 120 V 60 Hz Mains power supply Europe, Asia: AC 220 V - 240 V AC 50 Hz >1 kΩ...
  • Page 223: Extension Unit

    8.2.3 Extension unit 8.2.3.1 Physical characteristics Types HCS-8300MES Installation Tabletop Dimensions (mm) Color Black (PANTONE 419 C) Weight 1.5kg 8.2.3.2 Electrical characteristics Types HCS-8300MES Mains power supply AC 100 V - 240 V, 50 Hz / 60 Hz >1 kΩ Output load Maximum power consumption 150 W...
  • Page 224: Congress Unit

    8.3 Congress unit 8.3.1 HCS-8315 series congress unit Physical characteristics 8.3.1.1 Types HCS-8313/8314/8315 Installation Tabletop Dimensions (mm) Color Dark gray (PANTONE 426 C) Weight 0.45 kg Electrical characteristics 8.3.1.2 Types HCS-8313/8314/8315 Output frequency 30 - 20000 Hz response >16 Ω Earphone load Earphone volume 10 mW...
  • Page 225: Hcs-8335 Series Congress Unit

    8.3.2 HCS-8335 series congress unit 8.3.2.1 Physical characteristics Types HCS-8335(-NP) Installation Tabletop/Flush-mounted Dimensions (mm) Color silver (PANTONE 427 C) panel + black (PANTONE 419 C) base Weight 2.8 kg Types HCS-8335A Installation Tabletop/Flush-mounted Dimensions (mm) Color silver (PANTONE 427 C) panel + black (PANTONE 419 C) base Weight 2.8 kg 8.3.2.2 Electrical characteristics...
  • Page 226 Screen size 10", 16:10 Resolution 1280×800 Color (18 bit) Contrast 500:1 Type Uni-directional electret condenser microphone Sensitivity -46 dBV/Pa Frequency response 50 - 20000 Hz 2 kΩ Input impedance Directivity 0°/180° > 20 dB (1 kHz) Equivalent noise 20 dBA (SPL) Maximum sound 125 dB (THD<3%) pressure level...
  • Page 227: Hcs-8336 Sdi Monitor

    8.3.3 HCS-8336 SDI monitor 8.3.3.1 Physical characteristics Types HCS-8336 Installation Tabletop/Flush-mounted Dimensions (mm) Color silver (PANTONE 427 C) panel + black (PANTONE 419 C) base Weight 2.8 kg 8.3.3.2 Electrical characteristics Types HCS-8336 Max. power consumption Connection 6P-DIN dedicated cable with buckle BNC×1(75 Ω)...
  • Page 228: Hcs-8338/8348 Series Congress Terminal

    8.3.4 HCS-8338/8348 series congress terminal 8.3.4.1 Physical characteristics Types HCS-8338 Installation Tabletop Dimensions (mm) Silver-gray (PANTONE Cool Gray 7 C) panel + black (PANTONE 419 C) bottom case Color Weight 2.8 kg (incl. stem microphone) Types HCS-8348 Installation Tabletop Dimensions (mm) Color Silver-gray (PANTONE Cool Gray 7 C) panel + black (PANTONE 419 C) bottom case...
  • Page 229 8.3.4.2 Electrical characteristics Types HCS-8338 HCS-8338/FM HCS-8348 Output frequency response 30 - 20000 Hz >16 Ω Earphone load Earphone volume 10 mW Earphone output Ø 3.5 mm stereo jack 10 W Max. power consumption Connection Cat.6 1000M Ethernet cable Screen size 10", 16:10 1280×800 Resolution...
  • Page 230: Interpreter Unit

    8.4 Interpreter unit 8.4.1 HCS-8385 Physical characteristics 8.4.1.1 Type HCS-4385U/50 Installation Tabletop Dimensions (mm) Color Champagne (PANTONE 401 C) Weight 0.9 kg Electrical characteristics 8.4.1.2 Type HCS-4385U/50 Output frequency 30 - 20000 Hz response >16 Ω Earphone load Earphone volume 10 mW Earphone output Ø...
  • Page 231: Hcs-8385

    8.4.2 HCS-8385 8.4.2.1 Physical characteristics Type HCS-8385 Installation Tabletop Dimensions (mm) Color Champagne (PANTONE 401 C) 1.1 kg Weight Electrical characteristics 8.4.2.2 Output frequency response HCS-8385 30 - 20000 Hz Earphone load >16 Ω Earphone volume Earphone output Audio level is adjusted automatically according to impedance Ø...
  • Page 232: Hcs-8385Hdmi

    8.4.3 HCS-8385HDMI 8.4.3.1 Physical characteristics Type HCS-8385HDMI Installation Tabletop Dimensions (mm) Color Gray (PANTONE 425 C) Weight 0.4 kg 8.4.3.2 Electrical characteristics Type HCS-8385HDMI Signal type Connector Video 720p50,720p60 input Resolutions 1080i50,1080i60 1080p25,1080p30,1080p50,1080p60 Signal type HDMI Video Connectors 2 × female HDMI type A connectorI output Resolutions Up to 1080p60...
  • Page 233: Peripheral Equipment And Accessories

    8.5 Peripheral equipment and accessories 8.5.1 HCS-8300MO series Physical characteristics 8.5.1.1 Type HCS-8300MOD/FS(D) HCS-8300MOD HCS-8300MOA/FS(D) HCS-8300MOA Installation Tabletop / standard 19-inch rackmount Dimensions (mm) Color White (PANTONE 420 C) Weight 5.5 kg Electrical characteristics 8.5.1.2 Type HCS-8300MOD/FS(D) HCS-8300MOD HCS-8300MOA/FS(D) HCS-8300MOA Channels 8 CHs Frequency response...
  • Page 234: Hcs-8300Mi Series

    8.5.2 HCS-8300MI series Physical characteristics 8.5.2.1 Type HCS-8300MID/FS(D) HCS-8300MID HCS-8300MIA/FS(D) HCS-8300MIA Installation Tabletop / standard 19-inch rackmount Dimensions (mm) White (PANTONE 420 C) Color 5.5 kg Weight Electrical characteristics 8.5.2.2 Type HCS-8300MID/FS(D) HCS-8300MID HCS-8300MIA/FS(D) HCS-8300MIA Channels 8 CHs Frequency response 30 - 20000 Hz >90 dBA Dynamic range...
  • Page 235: Hcs-8300Mx

    8.5.3 HCS-8300MX Physical Characteristics 8.5.3.1 Type HCS-8300MX Installation Tabletop / standard 19-inch rackmount Dimensions (mm) White (PANTONE 420 C) Color 5.2 kg Weight Electrical Characteristics 8.5.3.2 Type HCS-8300MX Mains power supply 100 V - 240 V AC, 50/60 Hz >1 kΩ Output load Maximum power consumption 15 W...
  • Page 236: Hcs-8300Mx/Fs

    8.5.4 HCS-8300MX/FS 8.5.4.1 Physical characteristics Type HCS-8300MX/FS Installation Tabletop / standard 19-inch rackmount Dimensions (mm) Color White (PANTONE 420 C) Weight 7.4 kg 8.5.4.2 Electrical characteristics Type HCS-8300MX/FS Power supply AC 100 V - 120 V 60 Hz or AC 220 V - 240 V AC 50 Hz Maximum power consumption 200 W Dedicated cable (6-pin)
  • Page 237: Hcs-8302Mx/Fs

    8.5.5 HCS-8302MX/FS Physical characteristics 8.5.5.1 Type HCS-8302MX/FS Installation Tabletop / standard 19-inch rackmount Dimensions (mm) Color Gray (PANTONE 425 C) 5.24 kg Weight Electrical characteristics 8.5.5.2 Type HCS-8302MX/FS Power supply 100 V - 240 V AC, 50/60 Hz Maximum power consumption 65 W Connection Fiber...
  • Page 238: Hcs-8300Kmx

    Mains power supply 24 V - 33 V DC 2 × 2P aviation plugs for power supply from the Power Supply Unit HCS-8300 PM / PM2 Power input interface 1 × 6P-DIN interface for power supply from the congress main unit >1 kΩ...
  • Page 239: Hcs-8300Pm/Pm2

    8.5.7 HCS-8300PM/PM2 8.5.7.1 Physical Characteristics Type HCS-8300PM HCS-8300PM2 (dual backup) Installation Tabletop / standard 19-inch rackmount Dimensions (mm) Color White (PANTONE 420 C) Weight 10.3 kg 14.2 kg Electrical Characteristics 8.5.7.2 Type HCS-8300PM HCS-8300PM2 America, Japan: AC 100 V - 120 V 60 Hz Mains power supply Europe, Asia: AC 220 V - 240 V AC 50 Hz Maximum power...
  • Page 240: Hcs-8319

    8.5.8 HCS-8319 8.5.8.1 Physical Characteristics Type HCS-8319 Installation Tabletop Dimensions (mm) Color Gray (PANTONE Cool Gray 11 C) Weight 2.3 Kg Electrical Characteristics 8.5.8.2 Type HCS-8319 True color TFT LCD Type Dimension 10.2 inches Aspect Ratio 16:9 800×480 Resolution Brightness 400 cd/m Contrast 0.2775×0.2775 mm...
  • Page 241: Hcs-8301

    8.5.9 HCS-8301 8.5.9.1 Physical characteristics HCS-8301M Type HCS-8301MD Installation Tabletop Dimensions (mm) Color Dark blue (PANTONE 533 C) Weight 7.0 Kg 8.5.9.2 Electrical characteristics HCS-8301M Type HCS-8301MD Type True color TFT LCD Dimension 10.2 inches Aspect Ratio 16:9 Resolution 800×480 Brightness 400 cd/m Contrast...
  • Page 242: Microphone

    8.5.10 Microphone 8.5.10.1.1 Physical Characteristics Types MS24EMF1G/S MS33EMF1G/S/B MS41EMF1G/S/B MS47EMF1G/S/B Installation Insert microphone and tighten Length 240 mm 330 mm 410 mm 470 mm Color Silver (PANTONE 428 C) / Gray (PANTONE Cool Gray 11 C) / Black (PANTONE 419 C) Weight 75 g 85 g...
  • Page 243: Earphone

    8.5.11 Earphone  Frequency response of headphone: 20 Hz to 20  EP-820AS single earphone Sensitivity of headphone: ≥108 dBA/1 mW   Cooperates with the infrared receiver or the  Polar pattern of microphone: Omnidirectional congress unit  Frequency response of microphone: 50 Hz to 20 ...
  • Page 244  EP-960HD Detachable Earshells  Used for EP-960AH and EP-960BH  Earshell detachable washable, convenient for cleaning  Color: black  HCS-5100PA headphone  Cooperates with the infrared receiver or the congress unit  Hi-Fi sound quality 32 Ω×2, Ø 3.5 mm stereo jack ...
  • Page 245: Accessories

    8.5.12 Accessories   CBL6PS 6-pin dedicated extension cable CBL4PT-02 power branch cable CBL6PS-CMP 6-pin dedicated extension cable CBL4PT-02CMP power branch cable   For extending the connection between congress Power branch cable for “daisy-chain” supplying system main unit and congress unit power to HCS-8338 and HCS-8348 series ...
  • Page 246  Cat.5 cable  For connecting the PC and the congress system main unit  RJ45 crossing-line cable  Length: 3 m  Cat.6 cable  Connecting the HCS-8338 and HCS-8348 series paperless multimedia congress terminal and the HCS-8300KMX  Ethernet crossover cable with RJ45 connector at both ends ...
  • Page 247: System Connection

    8.6 System connection 8.6.1 Mains cables Blue Neutral Brown Hot (Phase) Green/Yellow Earth/Ground 8.6.2 Audio cables 3-pole XLR connector (female) Pin 1 Earth Pin 2 Signal + Pin 3 Signal - Chinch connector (male) Pin 1 Signal + Pin 2 GND 8.6.3 Earphone 3.5 mm Jack plug Tip (1) Signal left...
  • Page 248: Display Language List

    8.7 Display language list № № № Chinese English Abbr. Chinese English Abbr. Chinese English Abbr. 原声 巴厘语 加利西亚语 Floor Balinese Galician 阿尔巴尼亚 孟加拉国语 古吉特语 Albanian Bengali Gujarati 阿拉伯语 缅甸语 夏威夷语 Arabic Myanmar Hawaiian 保加利亚语 白俄罗斯语 坎那达语 Bulgarian Belarusian Kannada 加泰罗利亚...
  • Page 249: Appendices:custom-Made Cables

    Appendices:Custom-made cables AppendixⅠ: Dedicated 6 PIN Extension Cable...
  • Page 250: Appendix Ⅱ: Cbl2Ss-01 Professional 2-Pin Cable For Conference System

    Appendix Ⅱ: CBL2SS-01 Professional 2-pin Cable for Conference System...
  • Page 251: Appendix Ⅲ: Cbl4Pk-01 Power Adapter Cable

    Appendix Ⅲ: CBL4PK-01 Power Adapter Cable...
  • Page 252: Appendix Ⅳ: Cbl4Pt-02 Power Branch Cable

    Appendix Ⅳ: CBL4PT-02 Power Branch Cable...
  • Page 253: Appendix Ⅴ: Cbl4Ps 4-Pin Extension Cable

    Appendix Ⅴ: CBL4PS 4-pin Extension Cable...
  • Page 254: Appendix Ⅵ: Cat.6 Gigabit Ethernet Cable

    Appendix Ⅵ: Cat.6 Gigabit Ethernet Cable...
  • Page 255 TAIDEN INDUSTRIAL CO.,LTD. 6/F, Block B, Future Plaza, 6060 Qiaoxiang Rd, Nanshan District, Shenzhen,China P.C.: 518053 Copyright by TAIDEN Website: http://www.taiden.com Last Revision: 06/2016...

This manual is also suitable for:

Hcs-8300