No Response to DMX

Suspect the DMX cable or connectors, a controller malfunction, a light effect DMX card malfunction.
01) Check the DMX setting. Make sure that DMX addresses are correct.
02) Check the DMX cable: Unplug the unit; change the DMX cable; then reconnect to electrical power.
Try your DMX control again.
03) Determine whether the controller or light effect is at fault. Does the controller operate properly with
other DMX products? If not, take the controller in for repair. If so, take the DMX cable and the light
effect to a qualified technician.
Problem
Probable cause(s)
No power to the fixture
One or more
fixtures do not
function at all
Primary fuse blown
Fixtures reset
The controller is not connected.
correctly, but all
3-pin XLR Out of the controller
respond
does not match XLR Out of the first
erratically or not
fixture on the link (i.e. signal is
at all to the
reversed)
controller
Poor data quality
Bad data link connection
Fixtures reset
Data link not terminated with 120
correctly, but
Ohm termination plug
some respond
Incorrect addressing of the fixtures
erratically or not
at all to the
controller
One of the fixtures is defective and
disturbs data transmission on the
link
3-pin XLR Out on the fixtures does
not match (pins 2 and 3 reversed)
Fixture is too hot
No light or lamp
cuts out
intermittently
LEDs damaged
The power supply settings do not
match local AC voltage and
frequency
Ordercode: 42573
Solution
Check if power is switched on and
cables are plugged in
Replace fuse
Connect controller.
Install a phase reversing cable
between the controller and the
first fixture on the link
Check data quality. If much lower
than 100 percent, the problem
may be a bad data link
connection, poor quality or
broken cables, missing termination
plug, or a defective fixture
disturbing the link
Inspect connections and cables.
Correct poor connections. Repair
or replace damaged cables
Insert termination plug in output
jack of the last fixture on the link
Check address setting
Bypass one fixture at a time until
normal operation is restored:
unplug both connectors and
connect them directly together.
Have the defective fixture
serviced by a qualified technician
Install a phase-reversing cable
between the fixtures or swap pin 2
and 3 in the fixture that behaves
erratically
Allow the fixture to cool down
Clean the fan
Make sure air vents in control
panel and the front lens are not
blocked
Turn up the air conditioning
Disconnect the fixture and return it
to your dealer
Disconnect fixture. Check settings
and correct if necessary