Functions
5.2.3
Two protective functions
In this function mode, you configure independent protective functions with all associated safety parameters
for safety-related switching outputs OSSD-A and OSSD-B.
• For each protective function you can define up to ten field pairs in one configuration bank.
• Field pair actuation and field pair changeover take place separately and independently for each config-
uration bank.
For the field pair changeover, see chapter 5.7 "Field pair changeover".
5.2.4
One protective function – four field mode
The safety sensor monitors one protective field and three warning fields.
Monitoring is performed together for the field pairs of protective function A and protective function B. If, for
example, the control system is monitoring field pair A1.1 for protective function A, field pair B1.1 for protec-
tive function B is also monitored.
1
2
3
4
1
Protective function A: protective field
2
Protective function B: protective field
3
Protective function A: warning field
4
Protective function B: warning field
Fig. 5.1:
Four field mode
If the protective field of protective function A is violated, safety-related switching outputs OSSD-A switch.
If the protective field of protective function B is violated, the indication signal B-CLEAR is generated – the
safety-related switching outputs do not switch.
The signals are assigned to the switching outputs via the configuration and diagnostics software (CONFIG-
URATION > Outputs; see chapter 9 "Configuring the safety sensor").
Tab. 5.3:
Example: Assignment of signals to switching outputs
Logic signal Electrical switching output
OSSD A
B-CLEAR
A-WF-VIO
B-WF-VIO
Leuze electronic GmbH + Co. KG
A1.1P
B1.1P
A1.1W
B1.1W
Safety-related switching outputs OSSD A
Switching output MELD – not safe
Switching output A1
Switching output EA1
Description
Protective function A: protective field violation
Protective function B: protective field violation
Protective function A: Violation of warning field
Protective function B: Violation of warning field
RSL 440
34