Leuze electronic RSL 440 Original Operating Instructions page 129

Safety laser scanner
Table of Contents

Advertisement

Technical data
Byte
Bit
Protective function B
16
7
6
5
4
3
2
1
0
Field pair selection B
17
7-4
3-0
18
7-4
3-0
Output signals B
19
7
6
5
4
3
2
1
0
Leuze electronic GmbH + Co. KG
Signal
Description
B-ACTIVE
Protective function B is active /
configured
B-WF-VIO
Status of active warning field
Protective function B
B-PF-VIO
Status of active protective field
Protective function B
B-RES
Start/restart interlock active
Start request B
B-CLEAR
Internal signal OSSD B
Reserved
---
Reserved
---
Reserved
---
B-BANK-SEL
Selected bank B
Numbers 1 ... 10
B-PAIR-SEL 1
First selected field pair B
Numbers 1 ... 10
B-PAIR-SEL 2
Second selected field pair B
Numbers 1 ... 10
B-PAIR-SEL 3
Third selected field pair B
Numbers 1 ... 10
B-WF-VIO-SEG-1
Status of active warning field seg-
ment
Protective function B
B-WF-VIO-SEG-2
Status of active warning field seg-
ment
Protective function B
B-PF-VIO-SEG-1
Status of active protective field
segment
Protective function B
B-PF-VIO-SEG-2
Status of active protective field
segment
Protective function B
B-FP-SEL-1
Defined field pair selected
Protective function B
B-FP-SEL-2
Defined field pair selected
Protective function B
Reserved
---
Reserved
---
RSL 440
Value "0" Value "1" Default
off
Active
violation
free
violation
free
off
Active
off
on
---
---
---
---
---
---
---
---
---
---
---
---
---
---
violation
free
violation
free
violation
free
violation
free
off
selected
off
selected
---
---
---
---
0
0
0
0
0
---
---
---
0
0
0
0
0
0
0
0
0
0
---
---