Leuze electronic RSL 440 Original Operating Instructions page 128

Safety laser scanner
Table of Contents

Advertisement

Technical data
Byte
Bit
Protective function A
12
7
6
5
4
3
2
1
0
Field pair selection A
13
7-4
3-0
14
7-4
3-0
Output signals A
15
7
6
5
4
3
2
1
0
Leuze electronic GmbH + Co. KG
Signal
Description
A-ACTIVE
Protective function A is active /
configured
A-WF-VIO
Status of active warning field
Protective function A
A-PF-VIO
Status of active protective field
Protective function A
A-RES
Start/restart interlock active
Start Request A
A-CLEAR
Internal signal OSSD A
Reserved
---
Reserved
---
Reserved
---
A-BANK-SEL
Selected bank A
Numbers 1 ... 10
A-PAIR-SEL 1
First selected field pair A
Numbers 1 ... 10
A-PAIR-SEL 2
Second selected field pair A
Numbers 1 ... 10
A-PAIR-SEL 3
Third selected field pair A
Numbers 1 ... 10
A-WF-VIO-SEG-1
Status of active warning field seg-
ment
Protective function A
A-WF-VIO-SEG-2
Status of active warning field seg-
ment
Protective function A
A-PF-VIO-SEG-1
Status of active protective field
segment
Protective function A
A-PF-VIO-SEG-2
Status of active protective field
segment
Protective function A
A-FP-SEL-1
Defined field pair selected
Protective function A
A-FP-SEL-2
Defined field pair selected
Protective function A
Reserved
---
Reserved
---
RSL 440
Value "0" Value "1" Default
off
Active
violation
free
violation
free
off
Active
off
on
---
---
---
---
---
---
---
---
---
---
---
---
---
---
violation
free
violation
free
violation
free
violation
free
off
selected
off
selected
---
---
---
---
0
0
0
0
0
---
---
---
0
0
0
0
0
0
0
0
0
0
---
---
128