YASKAWA VIPA TP-ECO Manual page 57

Hide thumbs Also See for VIPA TP-ECO:
Table of Contents

Advertisement

VIPA HMI
System setting (Control
Panel)
Configuration MPI/DP
slave
HB160 | TP-ECO | 62K-NHC0 | en | 17-09
As many components of the Control Panel conform with the system control of Windows
most of the description is not necessary. The description of the control panel components
relevant for operating the Touch Panel can be found in the following:
n
Set display
Via 'Start è Settings è Control Panel è Display' the dialog windows for the display
properties opens. Here you can change the settings for the monitor options. For
example you can adjust the brightness via the register 'Backlight è Advanced'.
n
Calibrate touch screen
If the touch screen does not always react to a double click or not precisely recognize
the position of an entry, you can call the dialog Stylus via 'Start è Settings
è Control Panel'. In the register Double-Tap you can use the grid pattern to preset a
double click velocity and test this on the symbol below. Click [OK] to accept the value.
The calibration of the touch screen is completed via the register Calibration by fol-
lowing the instructions.
n
Set Ethernet parameters
The dialog field for pre-setting an Ethernet address is to be found at 'Start è Settings
è Network and Dial-up Connections'. The default setting is address assignment via
DHCP.
Please consider with the manual assignment of IP addresses that these
are not identical for both interfaces. If you accidentally have assigned to
the same IP address to both interfaces, then only one interface icon is
shown at 'Network and Dial- up Connections' . By switching to DHCP, you
receive 2 Interface icons again and can configure them individually.
n
System properties (System)
Here you receive information about the version of the current Windows
system, the memory load and sharing (alterations here are not accepted into the reg-
istry) and the copyright. The register Device Name allows you to change the device
name that is shown during Ethernet communication for instance.
To configure the optional MPI/DP interface on the Touch Panel start via 'Start è Settings
è Control Panel' or via 'Settings' in the VIPA Startup-Manager the tool "MPI/DP Slave
Configuration".
n
Default: MPI - Address 1
The following settings are only required if not communicate via Movicon.
Via 'mode' the interface could be set up on "DP slave".
Deployment under Windows CE 6.0 Prof.
Operating system WindowsÒ Embedded CE 6.0 Prof. > Structure
Ò
,
Ò
operating
57