Deployment under Windows CE 6.0 Core
Operating system WindowsÒ Embedded CE 6.0 Core > Structure
Configuration MPI/DP
slave
36
n
Set Ethernet parameters
The dialog field for pre-setting an Ethernet address is to be found at 'Start è Settings
è Network and Dial-up Connections'. The default setting is address assignment via
DHCP.
Please consider with the manual assignment of IP addresses that these
are not identical for both interfaces. If you accidentally have assigned to
the same IP address to both interfaces, then only one interface icon is
shown at 'Network and Dial- up Connections' . By switching to DHCP, you
receive 2 Interface icons again and can configure them individually.
n
System properties (System)
Here you receive information about the version of the current Windows
system, the memory load and sharing (alterations here are not taken over into the
registry) and about the copyright. The register Device Name allows you to change the
device name that is e.g. shown during Ethernet communication.
n
Set the back-lighting
Via 'Start è Settings è Control Panel è Power Properties' you may set the break
time and the dimming of the back-lighting. For this choose AC Power at "Power
Scheme" and then set the appropriate time.
A set suspend mode shuts down the Touch Panel completely. By
switching the power supply off and on again you can restart the Touch
Panel.
To configure the optional MPI/DP interface on the Touch Panel start via 'Start è Settings
è Control Panel' or via 'Settings' in the VIPA Startup-Manager the tool "MPI/DP Slave
Configuration".
n
Default: MPI - Address 1
The following settings are only required if not communicate via Movicon.
Via 'mode' the interface could be set up on "DP slave".