Hot-Swapping A Scsi Sca Hard Disk Drive - Intel AC450NX Product Manual

Rack server system
Hide thumbs Also See for AC450NX:
Table of Contents

Advertisement

AC450NX Rack Server System Product Guide

Hot-swapping a SCSI SCA Hard Disk Drive

Status LEDs are arranged in sets of three below each of the 2 hot-docking bays. They monitor the
status of each drive. When a yellow LED is on continuously, it is okay to hot-swap (remove and
replace) a bad drive with a good one. You do not need to shut the server down to hot-swap a drive.
SCSI Drive Status LED Descriptions
SCSI drive,
SCSI drive
power on
active
green LED
green LED
On
Off
On
Blinking
Off
Off
On
Off
Off
Off
*
The hot-swap controller is responsible for turning the yellow drive fault LED on or off according to the states specified
by commands received via SAF-TE and IMB.
See Figures 10-3 and 10-4.
1. Look at the yellow LEDs below the hot-docking bays to determine which drive is bad.
2. Push on the drive carrier latch of the bad drive, and while grasping the handle, pull the
assembly toward you to disengage the drive from the backplane connector.
3. Carefully slide the assembly out of the bay, and place it on an antistatic surface.
4. Orient the new carrier and drive assembly in front of the hot-docking bay guide rails so that
metal fingers of the perforated metal bracket attached to the carrier are facing up. Make sure
you correctly place the carrier into the guide rails to avoid damage.
5. While grasping only the drive carrier handle, firmly push the assembly into the bay until the
driver carrier latches.
CAUTION
Do not press on the perforated metal bracket of the carrier when you push
the assembly into the bay. Otherwise you may damage the metal fingers of
the bracket.
106
SCSI drive
faulty*
yellow LED
Description and action if needed
Drive is present with power.
Off
Drive is present with power and is being accessed.
Off
Drive CAN be replaced. Steady yellow fault light
On
indicates drive has a problem. Power to drive is off.
Drive SHOULD NOT be replaced at this time. A
Slow blinking
slowly blinking yellow fault light indicates that a drive
that has just been replaced is in recovery mode
(drive array being rebuilt). Power to drive is on.
There is no drive installed in the bay.
Off