Toyotomi CTN/CTG-328W User Manual page 47

Wall mounted air conditioner inverter type
Table of Contents

Advertisement

Available languages

Available languages

Step 2: Install drain joint
(only for some models)
1. Connect the outdoor drain joint into the hole on
the chassis, as shown in the picture below.
2. Connect the drain hose into the drain vent.
NOTE
As for the shape of drainage joint, please refer to the current product. Do not
install the drainage joint in the severe cold area. Otherwise, it will be frosted
and then cause malfunction
Step 3: Fix outdoor unit
1. Place the outdoor unit on the support.
2. Fix the foot holes of outdoor unit with bolts.
Step 4: Connect indoor and outdoor pipes
1. Remove the screw on the right handle of
outdoor unit and then remove the handle.
NOTE
When there're multiple cables passing
through it, the cross-hole of handle
should be knocked off and eliminate
the sharp burrs for avoid damaging the
cables.
Only applicable for some models.
47
drain vent
chassis
outdoor drain joint
Drain hose
foot holes
foot holes
handle
screw
cross-hole
GB

Advertisement

Table of Contents
loading

Table of Contents