1.0

APPLIANCE INFORMATION

Model
Gas type
Main injectors (2 off)
Pilot type (MC)
Pilot type (RC)
Max. gross heat input : 4.5 kW
Min. gross heat input : 3.5 kW
Cold pressure :
Ignition :
Electrode spark gap
Weight
Dimensions of Fire
Width :
(with fascia)
Height :
(with fascia)
Depth :
Flush-fit (from mounting face to rear)
Gas Connection
This appliance is manufactured by :-
BFM Europe Ltd,
Trentham Lakes,
Stoke-on-Trent,
ST4 4TJ.
Efficiency Declaration
The efficiency of this appliance has been measured as specified in
BS 7977-1 : 2009 + A1 : 2013 and the result is 76.6%.
The gross calorific value of the fuel has been used for this efficiency
calculation.
The test data from which it has been calculated has been certified by BSI.
The efficiency value may be used in the UK Government's Standard
Assessment Procedure (SAP) for energy rating of dwellings.
SECTION 1

INFORMATION AND REQUIREMENTS

FHKC**MN2
FHKC**RN3
G20
Size 130 (MC) 170 (RC)
Copreci 21100 / 141
ERTA OXYP PG-83-10
20.0 +/- 1.0 mbar
Push button piezo (MC models)
4.5V battery generator (RC models)
4.5mm nominal
25.5kg
8mm Compression
(Supplied with fire)
3
529mm
631mm
180mm